PURPOSE. The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. MATERIALS AND METHODS. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. RESULTS. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. CONCLUSION. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.

Abstract

PURPOSE. The purpose of this study was to evaluate the reliability of computer-aided replica technique (CART) by calculating its agreement with the replica technique (RT), using statistical agreement analysis. MATERIALS AND METHODS. A prepared metal die and a metal crown were fabricated. The gap between the restoration and abutment was replicated using silicone indicator paste (n = 25). Gap measurements differed in the control (RT) and experimental (CART) groups. In the RT group, the silicone replica was manually sectioned, and the marginal and occlusal gaps were measured using a microscope. In the CART group, the gap was digitized using optical scanning and image superimposition, and the gaps were measured using a software program. The agreement between the measurement techniques was evaluated by using the 95% Bland-Altman limits of agreement and concordance correlation coefficients (CCC). The least acceptable CCC was 0.90. RESULTS. The RT and CART groups showed linear association, with a strong positive correlation in gap measurements, but without significant differences. The 95% limits of agreement between the paired gap measurements were 3.84% and 7.08% of the mean. The lower 95% confidence limits of CCC were 0.9676 and 0.9188 for the marginal and occlusal gap measurements, respectively, and the values were greater than the allowed limit. CONCLUSION. The CART is a reliable digital approach for evaluating the fit accuracy of fixed dental prostheses.

참고문헌 (28)

  1. Holmes JR, "Considerations in measurement of marginal fit", J Prosthet Dent, 62, pp.405~408 (1989)
  2. Pimenta MA, "Evaluation of marginal and internal fit of ceramic and metallic crown copings using x-ray microtomography (micro-CT) technology", J Prosthet Dent, 114, pp.223~228 (2015)
  3. Contrepois M, "Marginal adaptation of ceramic crowns: a systematic review", J Prosthet Dent, 110, pp.447~454 (2013)
  4. Boitelle P, "A systematic review of CAD", CAM fit restoration evaluations, 2014, pp.41, 853~874
  5. Kianoosh Torabi, "The effect of various veneering techniques on the marginal fit of zirconia copings", The Journal of Advanced of Prosthodontics, 7(3), pp.233~239 (2015), 대한치과보철학회[DOI]
  6. 지민경, "Evaluation of marginal fit of 2 CAD-CAM anatomic contour zirconia crown systems and lithium disilicate glass-ceramic crown", The Journal of Advanced of Prosthodontics, 7(4), pp.271~277 (2015), 대한치과보철학회[DOI]
  7. Bugurman Burcu Bugurman, "Clinical gap changes after porcelain firing cycles of zirconia fixed dentures", The Journal of Advanced of Prosthodontics, 6(3), pp.177~184 (2014), 대한치과보철학회[DOI]
  8. 이완선, "Evaluation of different approaches for using a laser scanner in digitization of dental impressions", The Journal of Advanced of Prosthodontics, 6(1), pp.22~29 (2014), 대한치과보철학회[DOI]
  9. Falk A, "Reliability of the impression replica technique", Int J Prosthodont, 28, pp.179~180 (2015)
  10. Laurent M, "Clinical evaluation of the marginal fit of cast crowns-validation of the silicone replica method", J Oral Rehabil, 35, pp.116~122 (2008)
  11. Rahme HY, "In vitro evaluation of the "replica technique" in the measurement of the fit of Procera crowns", J Contemp Dent Pract, 9, pp.25~32 (2008)
  12. Coli P, "Fit of a new pressure-sintered zirconium dioxide coping", Int J Prosthodont, 17, pp.59~64 (2004)
  13. Chan DC, "The effect of sprue design on the marginal accuracy of titanium castings", J Oral Rehabil, 25, pp.424~429 (1998)
  14. Kim KB, "Three-dimensional evaluation of gaps associated with fixed dental prostheses fabricated with new technologies", J Prosthet Dent, 112, pp.1432~1436 (2014)
  15. Lee DH, "Digital approach to assessing the 3-dimensional misfit of fixed dental prostheses", J Prosthet Dent, 116, pp.836~839 (2016)
  16. Lin L, "Statistical methods in assessing agreement: Models, issues, and tools", J Am Stat Assoc, 97, pp.257~270 (2002)
  17. Barnhart HX, "Overall concordance correlation coefficient for evaluating agreement among multiple observers", Biometrics, 58, pp.1020~1027 (2002)
  18. Watson PF, "Method agreement analysis: a review of correct methodology", Theriogenology, 73, pp.1167~1179 (2010)
  19. Lin LI, "A concordance correlation coefficient to evaluate reproducibility", Biometrics, 45, pp.255~268 (1989)
  20. King TS, "A class of repeated measures concordance correlation coefficients", J Biopharm Stat, 17, pp.653~672 (2007)
  21. Lawrence I, "Assay validation using the concordance correlation coefficient", Biometrics, 48, pp.599~604 (1992)
  22. Cerna M, "Validity and reliability of the T-Scan(®) III for measuring force under laboratory conditions", J Oral Rehabil, 42, pp.544~551 (2015)
  23. King TS, "Robust estimators of the concordance correlation coefficient", J Biopharm Stat, 11, pp.83~105 (2001)
  24. Vonesh EF, "Goodness-of-fit in generalized nonlinear mixed-effects models", Biometrics, 52, pp.572~587 (1996)
  25. Lopez-Suarez C, "Marginal vertical discrepancies of monolithic and veneered zirconia and metal-ceramic three-unit posterior fixed dental prostheses", Int J Prosthodont, 29, pp.256~258 (2016)
  26. Kokubo Y, "Clinical marginal and internal gaps of In-Ceram crowns fabricated using the GN-I system", J Oral Rehabil, 32, pp.753~758 (2005)
  27. Giavarina D, "Understanding bland altman analysis", Biochem Med (Zagreb), 25, pp.141~151 (2015)
  28. 이예규, "Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition", The Journal of Advanced of Prosthodontics, 7(6), pp.460~467 (2015), 대한치과보철학회[DOI]

관련 논문AI추천

Comparison of three-dimensional digital technique with twodimensional replica method for measuring marginal and internal fit of full coverage restorationsMahya Hasanzade, Marzieh Alikhasi, Naeime Moslemian, Soudabeh Koulivand대한치과보철학회 · The Journal of Advanced of Prosthodontics2020 · 제12권 제3호Evaluation of the marginal and internal gaps of three different dental prostheses: comparison of the silicone replica technique and three-dimensional superimposition analysis김웅철, 김지환, 김혜영, 박진영, 배소연, 이재준대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제3호Comparison of the fit of cast gold crowns fabricated from the digital and the conventional impression techniques윤미정, 전영찬, 정창모, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제1호Accuracy evaluation of metal copings fabricated by computer-aided milling and direct metal laser sintering systems김웅철, 김지환, 김혜영, 박종경, 이완선대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제2호Comparison of the marginal fit of milled yttrium stabilized zirconium dioxide crowns obtained by scanning silicone impressions and by scanning stone replicasAntonio Minarro Alonso, Estefania Aranda Yus, Josep Maria Anglada Cantarell대한치과보철학회 · The Journal of Advanced of Prosthodontics2018 · 제10권 제3호Comparison of the fit accuracy of zirconia-based prostheses generated by two CAD/CAM systems조진현, 하석준대한치과보철학회 · The Journal of Advanced of Prosthodontics2016 · 제8권 제6호

이 간행물의 다른 논문 (11건)