초록
PURPOSE. To evaluate the adhesion to CAD/CAM feldspathic blocks by failure analysis and shear bond strength test (SBSt) of different restorative systems and different surface treatments, for purpose of moderate chipping repair. MATERIALS AND METHODS. A self-adhering flowable composite (Vertise Flow, Kerr) containing bi-functional phosphate monomers and a conventional flowable resin composite (Premise Flow, Kerr) applied with and without adhesive system (Optibond Solo Plus, Kerr) were combined with three different surface treatments (Hydrofluoric Acid Etching, Sandblasting, combination of both) for repairing feldspathic ceramics. Two commercial systems for ceramic repairing were tested as controls (Porcelain Repair Kit, Ultradent, and CoJet System, 3M). SBSt was performed and failure mode was evaluated using a digital microscope. A One-Way ANOVA (Tukey test for post hoc) was applied to the SBSt data and the Fisher’s Exact Test was applied to the failure analysis data. RESULTS. The use of resin systems containing bi-functional phosphate monomers combined with hydrofluoric acid etching of the ceramic surface gave the highest values in terms of bond strength and of more favorable failure modalities. CONCLUSION. The simplified repairing method based on self-adhering flowable resin combined with the use of hydrofluoric acid etching showed high bond strength values and a favorable failure mode. Repairing of ceramic chipping with a self-adhering flowable resin associated with hydrofluoric acid etching showed high bond strength with a less time consuming and technique-sensitive procedure compared to standard procedure.
Abstract
PURPOSE. To evaluate the adhesion to CAD/CAM feldspathic blocks by failure analysis and shear bond strength test (SBSt) of different restorative systems and different surface treatments, for purpose of moderate chipping repair. MATERIALS AND METHODS. A self-adhering flowable composite (Vertise Flow, Kerr) containing bi-functional phosphate monomers and a conventional flowable resin composite (Premise Flow, Kerr) applied with and without adhesive system (Optibond Solo Plus, Kerr) were combined with three different surface treatments (Hydrofluoric Acid Etching, Sandblasting, combination of both) for repairing feldspathic ceramics. Two commercial systems for ceramic repairing were tested as controls (Porcelain Repair Kit, Ultradent, and CoJet System, 3M). SBSt was performed and failure mode was evaluated using a digital microscope. A One-Way ANOVA (Tukey test for post hoc) was applied to the SBSt data and the Fisher’s Exact Test was applied to the failure analysis data. RESULTS. The use of resin systems containing bi-functional phosphate monomers combined with hydrofluoric acid etching of the ceramic surface gave the highest values in terms of bond strength and of more favorable failure modalities. CONCLUSION. The simplified repairing method based on self-adhering flowable resin combined with the use of hydrofluoric acid etching showed high bond strength values and a favorable failure mode. Repairing of ceramic chipping with a self-adhering flowable resin associated with hydrofluoric acid etching showed high bond strength with a less time consuming and technique-sensitive procedure compared to standard procedure.
참고문헌 (38)
- Kelly JR, "Ceramic materials in dentistry: historical evolution and current practice", Aust Dent J, 56, pp.84~96 (2011)
- Kelly JR, "Ceramics in dentistry:historical roots and current perspectives", J Prosthet Dent, 75, pp.18~32 (1996)
- Tan K, "A systematic review of the survival and complication rates of fixed partial dentures (FPDs) after an observation period of at least 5years", Clin Oral Implants Res, 15, pp.654~666 (2004)
- Sailer I, "A systematic review of the survival and complication rates of allceramic and metal-ceramic reconstructions after an observation period of at least 3 years. Part II: Fixed dental prostheses", Clin Oral Implants Res, 18, pp.86~96 (2007)
- Anusavice KJ, "Standardizing failure, success, and survival decisions in clinical studies of ceramic and metal-ceramic fixed dental prostheses", Dent Mater, 28, pp.102~111 (2012)
- Hickel R, "Repair of restorations-criteria for decision making and clinical recommendations", Dent Mater, 29, pp.28~50 (2013)
- Vita Zahnfabrik, "Vitablocs working instructions 1769E;05", 2012, 2012
- Heintze SD, "Survival of zirconia- and metal-supported fixed dental prostheses: a systematic review", Int J Prosthodont, 23, pp.493~502 (2010)
- Burke FJ, "Repair of fractured porcelain units: alternative approaches", Br Dent J, 176, pp.251~256 (1994)
- Kimmich M, "Intraoral treatment of veneering porcelain chipping of fixed dental restorations: a review and clinical application", J Am Dent Assoc, 144, pp.31~44 (2013)
- Reston EG, "Repairing ceramic restorations: final solution or alternative procedure?", Oper Dent, 33, pp.461~466 (2008)
- Blum IR, "Defective dental restorations:to repair or not to repair? Part 2: All-ceramics and porcelain fused to metal systems", Dent Update, 38, pp.150~152 (2011)
- Vichi A, "Bonding and sealing ability of a new self-adhering flowable composite resin in class I restorations", Clin Oral Investig, 17, pp.1497~1506 (2013)
- Goracci C, "Shear bond strength of orthodontic brackets bonded with a new self-adhering flowable resin composite", Clin Oral Investig, 17, pp.609~617 (2013)
- Pashley DH, "The microtensile bond test: a review", J Adhes Dent, 1, pp.299~309 (1999)
- Sano H, "Relationship between surface area for adhesion and tensile bond strength-evaluation of a micro-tensile bond test", Dent Mater, 10, pp.236~240 (1994)
- Perdigão J, "In vitro bonding performance of all-in-one adhesives. Part I-microtensile bond strengths", J Adhes Dent, 8, pp.367~373 (2006)
- Sadek FT, "The influence of the cutting speed on bond strength and integrity of microtensile specimens", Dent Mater, 21, pp.1144~1149 (2005)
- Goracci C, "Influence of substrate, shape, and thickness on microtensile specimens’ structural integrity and their measured bond strengths", Dent Mater, 20, pp.643~654 (2004)
- Tylka DF, "Comparison of acidulated phosphate fluoride gel and hydrofluoric acid etchants for porcelain-composite repair", J Prosthet Dent, 72, pp.121~127 (1994)
- Della Bona A, "Shear vs. tensile bond strength of resin composite bonded to ceramic", J Dent Res, 74, pp.1591~1596 (1995)
- Ferrari M, "Microtensile bond strength tests: scanning electron microscopy evaluation of sample integrity before testing", Eur J Oral Sci, 110, pp.385~391 (2002)
- Knight JS, "Shear bond strengths of composite bonded to porcelain using porcelain repair systems", Am J Dent, 16, pp.252~254 (2003)
- van der Vyver PJ, "Shear bond strength of five porcelain repair systems on cerec porcelain", SADJ, 60, pp.196~198 (2005)
- 유지영, "Porcelain repair - Influence of different systems and surface treatments on resin bond strength", The Journal of Advanced of Prosthodontics, 7(5), pp.343~348 (2015), 대한치과보철학회[DOI]
- Ugur Erdemir, "Shear bond strength of a new selfadhering flowable composite resin for lithium disilicate-reinforced CAD", CAM ceramic material, 2014, pp.6(6), 434~443[DOI]
- Natasya Ahmad Tarib, "Shear bond strength of veneering ceramic to coping materials with different pre-surface treatments", The Journal of Advanced of Prosthodontics, 8(5), pp.339~344 (2016), 대한치과보철학회[DOI]
- Goia TS, "Repair bond strength of a resin composite to alumina-reinforced feldspathic ceramic", Int J Prosthodont, 19, pp.400~ (2006)
- Queiroz JR, "Influence of acid-etching and ceramic primers on the repair of a glass ceramic", Gen Dent, 60, pp.e79~e85 (2012)
- Newburg R, "Composite resins bonded to porcelain with silane solution", J Am Dent Assoc, 96, pp.288~291 (1978)
- Stangel I, "Shear strength of the composite bond to etched porcelain", J Dent Res, 66, pp.1460~1465 (1987)
- Ozcan M, "Bond strength durability of a resin composite on a reinforced ceramic using various repair systems", Dent Mater, 25, pp.1477~1483 (2009)
- Kumbuloglu O, "Intra-oral adhesive systems for ceramic repairs: a comparison", Acta Odontol Scand, 61, pp.268~272 (2003)
- Kussano CM, "Evaluation of shear bond strength of composite to porcelain according to surface treatment", Braz Dent J, 14, pp.132~135 (2003)
- "Vertise Flow Technical Bulletin, Kerr Corporation Lit. No. 34929B"[URL]
- Addison O, "Adhesive luting of allceramic restorations-the impact of cementation variables and short-term water storage on the strength of a feldspathic dental ceramic", J Adhes Dent, 10, pp.285~293 (2008)
- Timokhin AR, "Chemical reaction of ammonium bifluoride with quartz glass", Glass Ceram, 42, pp.267~269 (1985)
- Yen TW, "Effect of acid etching on the flexural strength of a feldspathic porcelain and a castable glass ceramic", J Prosthet Dent, 70, pp.224~233 (1993)