PURPOSE. The objectives of this study were to evaluate the fracture strength and fracture patterns of provisional crowns fabricated from different materials and techniques after receiving stress from a simulated oral condition. MATERIALS AND METHODS. A monomethacrylate-based resin (Unifast Trad) and a bis-acryl-based (Protemp 4) resin were used to fabricate provisional crowns using conventional direct technique. A milled monomethacrylate resin (Brylic Solid) and a 3D-printed bis-acrylate resin (Freeprint Temp) were chosen to fabricate provisional crowns using the CAD/CAM process. All cemented provisional crowns (n=10/group) were subjected to thermal cycling (5,000 cycles at 5°-55 C) and cyclic occlusal load (100 N at 4 Hz for 100,000 cycles). Maximum force at fracture was tested using a universal testing machine. RESULTS. Maximum force at fracture (mean ± SD, N) of each group was 657.87 ± 82.84 for Unifast Trad, 1125.94 ± 168.07 for Protemp4, 953.60 ± 58.88 for Brylic Solid, and 1004.19 ± 122.18 for Freeprint Temp. One-way ANOVA with Tamhane post hoc test showed that the fracture strength of Unifast Trad was statistically significantly lower than others (P<.01). No statistically significant difference was noted among other groups. For failure pattern analysis, Unifast Trad and Brylic Solid showed less damage than Protemp 4 and Freeprint Temp groups. CONCLUSION. Provisional crowns fabricated using the CAD/CAM process and the conventionally fabricated bis-acryl resins exhibited significant higher fracture strength compared to conventionally fabricated monomethacrylate resins after the aging regimen. Therefore, CAD/CAM milling and 3D printing of provisional restorations may be good alternatives for long term provisionalization.

Abstract

PURPOSE. The objectives of this study were to evaluate the fracture strength and fracture patterns of provisional crowns fabricated from different materials and techniques after receiving stress from a simulated oral condition. MATERIALS AND METHODS. A monomethacrylate-based resin (Unifast Trad) and a bis-acryl-based (Protemp 4) resin were used to fabricate provisional crowns using conventional direct technique. A milled monomethacrylate resin (Brylic Solid) and a 3D-printed bis-acrylate resin (Freeprint Temp) were chosen to fabricate provisional crowns using the CAD/CAM process. All cemented provisional crowns (n=10/group) were subjected to thermal cycling (5,000 cycles at 5°-55 C) and cyclic occlusal load (100 N at 4 Hz for 100,000 cycles). Maximum force at fracture was tested using a universal testing machine. RESULTS. Maximum force at fracture (mean ± SD, N) of each group was 657.87 ± 82.84 for Unifast Trad, 1125.94 ± 168.07 for Protemp4, 953.60 ± 58.88 for Brylic Solid, and 1004.19 ± 122.18 for Freeprint Temp. One-way ANOVA with Tamhane post hoc test showed that the fracture strength of Unifast Trad was statistically significantly lower than others (P<.01). No statistically significant difference was noted among other groups. For failure pattern analysis, Unifast Trad and Brylic Solid showed less damage than Protemp 4 and Freeprint Temp groups. CONCLUSION. Provisional crowns fabricated using the CAD/CAM process and the conventionally fabricated bis-acryl resins exhibited significant higher fracture strength compared to conventionally fabricated monomethacrylate resins after the aging regimen. Therefore, CAD/CAM milling and 3D printing of provisional restorations may be good alternatives for long term provisionalization.

참고문헌 (27)

  1. Burns DR, "A review of selected dental literature on contemporary provisional fixed prosthodontic treatment: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics", J Prosthet Dent, 90, pp.474~497 (2003)
  2. Haselton DR, "Flexural strength of provisional crown and fixed partial denture resins", J Prosthet Dent, 87, pp.225~228 (2002)
  3. Astudillo-Rubio D, "Mechanical properties of provisional dental materials : A systematic review and meta-analysis", PLoS One, 13, pp.e0193162~ (2018)
  4. Abdulmohsen B, "A study to investigate and compare the physicomechanical properties of experimental and commercial temporary crown and bridge materials", Dent Mater, 32, pp.200~210 (2016)
  5. Alp G, "Comparison of flexural strength of different CAD", CAM PMMA-based polymers, 2019, pp.28, e491~e495
  6. Lang R, "Fracture resistance of PMMA and resin matrix composite-based interim FPD materials", Int J Prosthodont, 16, pp.381~384 (2003)
  7. Nejatidanesh F, "Flexural strength of interim resin materials for fixed prosthodontics", J Prosthodont, 18, pp.507~511 (2009)
  8. van Noort R, "The future of dental devices is digital", Dent Mater, 28, pp.3~12 (2012)
  9. Alghazzawi TF, "Advancements in CAD", CAM technology : options for practical implementation, 2016, pp.60, 72~84
  10. Digholkar S, "Evaluation of the flexural strength and microhardness of provisional crown and bridge materials fabricated by different methods", J Indian Prosthodont Soc, 16, pp.328~334 (2016)
  11. Rayyan MM, "Comparison of interim restorations fabricated by CAD", CAM with those fabricated manually, 2015, pp.114, 414~419
  12. Yao J, "Comparison of the flexural strength and marginal accuracy of traditional and CAD", CAM interim materials before and after thermal cycling, 2014, pp.112, 649~657
  13. Isil Karaokutan, "In vitro study of fracture strength of provisional crown materials", The Journal of Advanced of Prosthodontics, 7(1), pp.27~31 (2015), 대한치과보철학회[DOI]
  14. Tahayeri A, "3D printed versus conventionally cured provisional crown and bridge dental materials", Dent Mater, 34, pp.192~200 (2018)
  15. Alt V, "Fracture strength of temporary fixed partial dentures : CAD", CAM versus directly fabricated restorations, 2011, pp.27, 339~347
  16. Abdullah AO, "Comparative in vitro evaluation of CAD", CAM vs conventional provisional crowns, 2016, pp.24, 258~263
  17. Nakamura T, "In vitro study on marginal and internal fit of CAD", CAM all-ceramic crowns, 2005, pp.24, 456~459
  18. Heintze SD, "Fracture frequency of all-ceramic crowns during dynamic loading in a chewing simulator using different loading and luting protocols", Dent Mater, 24, pp.1352~1361 (2008)
  19. Burke FJ, "Fracture resistance of teeth restored with dentinbonded crowns constructed in a leucite-reinforced ceramic", Dent Mater, 15, pp.359~362 (1999)
  20. Balkenhol M, "Fracture toughness of cross-linked and non-cross-linked temporary crown and fixed partial denture materials", Dent Mater, 25, pp.917~928 (2009)
  21. Stawarczyk B, "Load-bearing capacity of CAD", CAM milled polymeric three-unit fixed dental prostheses : effect of aging regimens, 2012, pp.16, 1669~1677
  22. Mei ML, "Effect of heat treatment on the physical properties of provisional crowns during polymerization:an in vitro study", Materials, 8, pp.1766~1777 (2015)
  23. Edelhoff D, "CAD", CAM-generated high-density polymer restorations for the pretreatment of complex cases : a case report, 2012, pp.43, 457~467
  24. Giordano R, "Materials for chairside CAD", CAM-produced restorations, 2006, pp.137, 14S~21S
  25. Balkenhol M, "Correlation between polymerization shrinkage and marginal fit of temporary crowns", Dent Mater, 24, pp.1575~1584 (2008)
  26. Liebermann A, "Physicomechanical characterization of polyetheretherketone and current esthetic dental CAD", CAM polymers after aging in different storage media, 2016, pp.115, 321~328.e2
  27. Mandelaris GA, "Guided implant surgery with placement of a presurgical CAD", CAM patient-specific abutment and provisional in the esthetic zone, 2014, pp.35, 494~504

관련 논문AI추천

In vitro study of fracture strength of provisional crown materialsGulsum Sayin, Isil Karaokutan, Ozlem Kara대한치과보철학회 · The Journal of Advanced of Prosthodontics2015 · 제7권 제1호Comparison of fracture strength, surface hardness, and color stain of conventionally fabricated, 3D printed, and CAD-CAM milled interim prosthodontic materials after thermocyclingFiliz Aykent, Mahmut Sertaç Özdoğan, Mesut Yıldırım대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제2호Effect of thermomechanical aging on fracture strength of anterior crowns fabricated with different CAD-CAM materialsErkut Kahramanoğlu, Hatice Banu Özel, Mine Helvacıoğlu Özkardeş대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제3호Influence of surface treatments and repair materials on the shear bond strength of CAD/CAM provisional restorations김성훈, 정기원대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제2호Assessment of effect of accelerated aging on interim fixed dental materials using digital technologiesAbdullah Alshehri, Fares Alhabbad, Haitham Almansour, Majed Alsarani, Omar Alageel, Omar Alsadon대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제6호절삭가공과 적층가공으로 제작한 임시수복물의 두께에 따른 굴곡강도 비교김민선, 이재인대한치과의사협회 · 대한치과의사협회지2022 · 제60권 제9호

이 간행물의 다른 논문 (9건)