Accuracy assessment of intraoral scanning versus conventional impressions in edentulous patients with flabby ridges: a prospective clinical study

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose. This prospective clinical study aimed to evaluate the accuracy of intraoral scanning (IOS) as an alternative to the conventional window technique impression (WTI) for recording maxillary flabby ridges in edentulous patients. Materials and methods. Twelve edentulous participants with maxillary flabby ridges underwent both IOS (TRIOS 5, 3Shape, Denmark) and WTI. WTI impressions were made using zinc oxide-eugenol paste and plaster of Paris as the reference. All scans were exported in STL format. Accuracy was assessed via trueness and precision, using RMS, average negative, and average positive deviations, calculated with Medit Compare software. Results. IOS showed significantly higher trueness than WTI in RMS (mean difference (MD) = -0.11, 95% CI: -0.15 to -0.06, P = .0001) and average negative deviation (MD = 0.13, 95% CI: 0.07 to 0.19, P = .0001). The average positive deviation had no significant difference (MD = 0.02, 95% CI: -0.01 to 0.05, P = .11). In terms of precision, IOS had significantly higher precision across all parameters: RMS (MD = 0.23, 95% CI: 0.21 to 0.26, P = .0001), average positive deviation (MD = 0.14, 95% CI: 0.11 to 0.17, P = .0001), and average negative deviation (MD = -0.15, 95% CI: -0.17 to -0.13, P = .0001). Conclusion. This study suggests that IOS may provide improved accuracy compared to the conventional window impression technique for capturing maxillary flabby ridges in edentulous patients. Further research with larger sample size and clinical outcome assessments is needed to confirm its efficacy.

Abstract

Purpose. This prospective clinical study aimed to evaluate the accuracy of intraoral scanning (IOS) as an alternative to the conventional window technique impression (WTI) for recording maxillary flabby ridges in edentulous patients. Materials and methods. Twelve edentulous participants with maxillary flabby ridges underwent both IOS (TRIOS 5, 3Shape, Denmark) and WTI. WTI impressions were made using zinc oxide-eugenol paste and plaster of Paris as the reference. All scans were exported in STL format. Accuracy was assessed via trueness and precision, using RMS, average negative, and average positive deviations, calculated with Medit Compare software. Results. IOS showed significantly higher trueness than WTI in RMS (mean difference (MD) = -0.11, 95% CI: -0.15 to -0.06, P = .0001) and average negative deviation (MD = 0.13, 95% CI: 0.07 to 0.19, P = .0001). The average positive deviation had no significant difference (MD = 0.02, 95% CI: -0.01 to 0.05, P = .11). In terms of precision, IOS had significantly higher precision across all parameters: RMS (MD = 0.23, 95% CI: 0.21 to 0.26, P = .0001), average positive deviation (MD = 0.14, 95% CI: 0.11 to 0.17, P = .0001), and average negative deviation (MD = -0.15, 95% CI: -0.17 to -0.13, P = .0001). Conclusion. This study suggests that IOS may provide improved accuracy compared to the conventional window impression technique for capturing maxillary flabby ridges in edentulous patients. Further research with larger sample size and clinical outcome assessments is needed to confirm its efficacy.

관련 논문AI추천

Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scansChristine Keul, Jan-Frederik Güth, Oliver Schubert, Panagiotis Kontis대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제5호Comparison of different impression techniques for edentulous jaws using three-dimensional analysis박찬, 박상원, 양홍서, 윤귀덕, 임현필, 정수아, Zhai Ying대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제3호Palatal vault configuration and its influence on intraoral scan time and accuracy in completely edentulous arches: a prospective clinical studyDina Mohamed Ahmed Elawady, Radwa Gamal Ghanem, Reham Bassuni Osman, Wafaa Ibrahim Ibrahim대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제4호Comparison of the accuracy of removable partial denture frameworks fabricated using conventional and digital impressions: a clinical study강유정, 김지환, 선민지, 윤명아, 전정호대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제5호Effect of reference objects on the accuracy of digital implant impressions in partially edentulous archesAgnė Gedrimienė, Darius Jegelevičius, Justinas Pletkus, Liudas Auškalnis, Mutlu Özcan, Mykolas Akulauskas, Tan Fırat Eyüboğlu, Vygandas Rutkūnas대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제5호Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressionsFunda Bayindir, Ismail Hakki Korkmaz, Ozcan Akkal대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제4호

이 간행물의 다른 논문 (5건)