포도당 모니터링을 위한 비침습적 정량화 방법
Non-invasive quantification methods for glucose monitoring
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Diabetes mellitus is an abnormally high glucose level in the bloodstream. Several pharmaceuticals are administered to diabetic patients to control their glucose levels. Early diagnosis and proper glycemic management are essential in this situation to prevent further progression and complications. Biosensor-based detection has progressed and shown potential in portable and inexpensive daily assessment of glucose levels because of its simplicity, low cost, and convenient operation without sophisticated instrumentation. This review discusses various systemic aspects of non-invasive glucose monitoring, including materials for monitoring and managing diabetes.
Abstract
Diabetes mellitus is an abnormally high glucose level in the bloodstream. Several pharmaceuticals are administered to diabetic patients to control their glucose levels. Early diagnosis and proper glycemic management are essential in this situation to prevent further progression and complications. Biosensor-based detection has progressed and shown potential in portable and inexpensive daily assessment of glucose levels because of its simplicity, low cost, and convenient operation without sophisticated instrumentation. This review discusses various systemic aspects of non-invasive glucose monitoring, including materials for monitoring and managing diabetes.
참고문헌 (34)
- Soliman A, "Continuous glucose monitoring system and new era of early diagnosis of diabetes in high risk groups", Indian journal of endocrinology and metabolism, 18, pp.274~ (2014)
- Heller A, "Implanted electrochemical glucose sensors for the management of diabetes", Annual Review of Biomedical Engineering, 1, pp.153~175 (1999)
- Kap Ö, "Smartphone-based colorimetric detection systems for glucose monitoring in the diagnosis and management of diabetes", Analyst, 146, pp.2784~2806 (2021)
- Steiner M-S, "Optical methods for sensing glucos", Chemical Society Reviews, 40, pp.4805~4839 (2011)
- Delbeck S, "Non-invasive monitoring of blood glucose using optical methods for skin spectroscopy—opportunities and recent advances", Analytical and bioanalytical chemistry, 411, pp.63~77 (2019)
- Chen C, "Recent advances in electrochemical glucose biosensors: a review", Rsc Advances, 3, pp.4473~4491 (2013)
- Kost J, "Transdermal monitoring of glucose and other analytes using ultrasound", Nature medicine, 6, pp.347~350 (2000)
- Oliver N, "Glucose sensors:a review of current and emerging technology", Diabetic Medicine, 26, pp.197~210 (2009)
- Jv Y, "Positively-charged gold nanoparticles as peroxidiase mimic and their application in hydrogen peroxide and glucose detection", Chemical communications, 46, pp.8017~8019 (2010)
- Shiang Y-C, "Gold nanodot-based luminescent sensor for the detection of hydrogen peroxide and glucose", Chemical communications, 2009, pp.3437~3439 (2009)
- Yu F, "The artificial peroxidase activity of magnetic iron oxide nanoparticles and its application to glucose detection", Biomaterials, 30, pp.4716~4722 (2009)
- Wei H, "Fe3O4 magnetic nanoparticles as peroxidase mimetics and their applications in H2O2 and glucose detection", Analytical chemistry, 80, pp.2250~2254 (2008)
- Ebrahimi A, "Microwave reflective biosensor for glucose level detection in aqueous solutions", Sensors and Actuators A: Physical, 301, pp.111662~ (2020)
- Kim N, "A reusable robust radio frequency biosensor using microwave resonator by integrated passive device technology for quantitative detection of glucose level", Biosensors and Bioelectronics, 67, pp.687~693 (2015)
- An Y-H, "Facilitated transdermal drug delivery using nanocarriers-embedded electroconductive hydrogel coupled with reverse electrodialysis-driven iontophoresis", ACS nano, 14, pp.4523~4535 (2020)
- Frontino G, "Future perspectives in glucose monitoring sensors", European Endocrinology, 9, pp.6~ (2013)
- Thennadil SN, "Comparison of glucose concentration in interstitial fluid, and capillary and venous blood during rapid changes in blood glucose levels", Diabetes Technology &Therapeutics, 3, pp.357~365 (2001)
- Shervedani RK, "A novel method for glucose determination based on electrochemical impedance spectroscopy using glucose oxidase self-assembled biosensor", Bioelectrochemistry, 69, pp.201~208 (2006)
- Perumal V, "Advances in biosensors: Principle, architecture and applications", Journal of applied biomedicine, 12, pp.1~15 (2014)
- Bollella P, "Beyond graphene: electrochemical sensors and biosensors for biomarkers detection", Biosensors and Bioelectronics, 89, pp.152~166 (2017)
- Tang L, "Non-invasive blood glucose monitoring technology: a review", Sensors, 20, pp.6925~ (2020)
- Xue X, "Statistical and hydrological evaluation of TRMM-based Multi-satellite Precipitation Analysis over the Wangchu Basin of Bhutan : Are the latest satellite precipitation products 3B42V7 ready for use in ungauged basins?", Journal of Hydrology, 499, pp.91~99 (2013)
- Joo S, "Structural insight into molecular mechanism of poly (ethylene terephthalate) degradation", Nature communications, 9, pp.1~12 (2018)
- Adeel M, "Recent advances of electrochemical and optical enzyme-free glucose sensors operating at physiological conditions", Biosensors and Bioelectronics, 165, pp.112331~ (2020)
- Kim S, "Tear glucose measurement by reflectance spectrum of a nanoparticle embedded contact lens", Scientific reports, 10, pp.1~8 (2020)
- Kanchi S, "Smartphone based bioanalytical and diagnosis applications: A review", Biosensors and Bioelectronics, 102, pp.136~149 (2018)
- Jeon H-J, "Optical assessment of tear glucose by smart biosensor based on nanoparticle embedded contact lens", Nano Letters, 21, pp.8933~8940 (2021)
- Ahmadi M, "Application of magnetic nanomaterials in electroanalytical methods: A review", Talanta, 225, pp.121974~ (2021)
- Wang Q, "One-pot synthesis of Fe3O4 nanoparticle loaded 3D porous graphene nanocomposites with enhanced nanozyme activity for glucose detection", ACS applied materials & interfaces, 9, pp.7465~7471 (2017)
- Shiraga K, "Broadband dielectric spectroscopy of glucose aqueous solution: Analysis of the hydration state and the hydrogen bond network", The Journal of chemical physics, 142, pp.234504~ (2015)
- Hofmann M, "Microwave-based noninvasive concentration measurements for biomedical applications", IEEE Transactions on Microwave Theory and Techniques, 61, pp.2195~2204 (2013)
- Yilmaz T, "Towards accurate dielectric property retrieval of biological tissues for blood glucose monitoring", IEEE transactions on Microwave Theory and Techniques, 62, pp.3193~3204 (2014)
- Juan CG, "Microwave planar resonant solutions for glucose concentration sensing: A systematic review", Applied Sciences, 11, pp.7018~ (2021)
- Jeon H-J, "Cyber-Physical Watermarking with Inkjet Edible Bioprinting", Advanced Functional Materials, 2022, pp.2112479~ (2022)
