본문 바로가기
KERD
논문KCI 등재

무채혈 혈당 측정기의 혈당 측정 원리: 혈당 검출방법 중심으로

Blood Glucose Measurement Principles of Non-invasive Blood Glucose Meter: Focused on the Detection Methods of Blood Glucose

1

조회

0

다운로드

4

인용

0

참고문헌

키워드

초록

Recent technical advancement allows noninvasive measurement of blood glucose. In this literature, we reviewed various noninvasive techniques for measuring glucose concentration. Optical or electrical methods have been investigated. Optical techniques include near-infrared spectroscopy, Raman spectroscopy, optical coherence technique, polarization, fluorescence, occlusion spectroscopy, and photoacoustic spectroscopy. Electrical methods include reverse iontophoresis, impedance spectroscopy, and electromagnetic sensing. Ultrasound, detection from breath, or fluid harvesting technique can be used to measure blood glucose level. Combination of various methods is also promising. Although there are many interesting and promising technologies and devices, there need further researches until a commercially available non-invasive glucometer is popular.

Abstract

Recent technical advancement allows noninvasive measurement of blood glucose. In this literature, we reviewed various noninvasive techniques for measuring glucose concentration. Optical or electrical methods have been investigated. Optical techniques include near-infrared spectroscopy, Raman spectroscopy, optical coherence technique, polarization, fluorescence, occlusion spectroscopy, and photoacoustic spectroscopy. Electrical methods include reverse iontophoresis, impedance spectroscopy, and electromagnetic sensing. Ultrasound, detection from breath, or fluid harvesting technique can be used to measure blood glucose level. Combination of various methods is also promising. Although there are many interesting and promising technologies and devices, there need further researches until a commercially available non-invasive glucometer is popular.

참고문헌 (49)

  1. Korean Diabetes Association, "Health Insurance Review & Assessment service : Task Force Team for Basic Statistical Study of Korean Diabetes Mellitus, In diabetes, 1st ed", pp.14~17 (2007), Golden Fishing Ground
  2. UK Prospective Diabetes Study (UKPDS) Group, "Intensive blood-glucose control with sulphonylureas or insulin compared with conventional treatment and risk of complications in patients with type 2 diabetes (UKPDS 33)", Lancet, 352(9131), pp.837~853 (1998)
  3. The Diabetes, Control and Complications Trial Research, Group, "The Effect Of Intensive Treatment Of Diabetes On The Development And Progression Of Long-Term Complications In Insulin-Dependent Diabetes Mellitus", New England Journal of Medicine, 329(14), pp.977~986 (1993)
  4. D.E. Goldstein, "Tests of Glycemia in Diabetes", Diabetes Care, 27(7), pp.1761~1773 (2004)
  5. 김현식, "피부관통시 통증을 최소화하는 일회용 자동 모세혈액 채취기구", 의공학회지, 23(4), pp.323~327 (2002), 대한의용생체공학회
  6. 박경순, "에러그리드를 사용한 대체부위 혈당검사의 유용성 검증", 의공학회지, 32(1), pp.25~31 (2011), 대한의용생체공학회
  7. O.S. Khalil, "Non-invasive glucose measurement technologies: an update from 1999 to the dawn of the new millennium", Diabetes Technol Ther, 6(5), pp.660~697 (2004)
  8. A. Sieg, "Noninvasive and minimally invasive methods for transdermal glucose monitoring", Diabetes Technol Ther, 7(1), pp.174~197 (2005)
  9. H.W. Lim, "Clinical Photomedicine", pp.19~35 (1993)
  10. R.R. Anderson, "The optics of human skin", J Invest Dermatol, 77(1), pp.13~19 (1981)
  11. S.F. Malin, "Noninvasive prediction of glucose by near-infrared diffuse reflectance spectroscopy", Clin Chem, 45(9), pp.1651~1658 (1999)
  12. 이승덕, "근적외선 분광법 및 확산 광 영상법의 최근 연구 동향", 의공학회지, 29(2), pp.89~98 (2008), 대한의용생체공학회
  13. S.J. Yeh, "Monitoring blood glucose changes in cutaneous tissue by temperature-modulated localized reflectance measurements", Clin Chem, 49(6 Pt 1), pp.924~934 (2003)
  14. E.B. Hanlon, "Prospects for in vivo Raman spectroscopy", Phys Med Biol, 45(2), pp.1~59 (2000)
  15. J.L. Lambert, "Measurement of aqueous glucose in a model anterior chamber using Raman spectroscopy", Journal of Raman Spectroscopy, 33(7), pp.524~529 (2002)
  16. J.P. Wicksted, "Monitoring of aqueous humor metabolites using Raman spectroscopy", 2135, pp.264~274 (1994)
  17. S.Y. Wang, "Analysis of metabolites in aqueous solutions by using laser Raman spectroscopy", Appl Opt, 32(6), pp.925~929 (1993)
  18. G.L. Cote, "Noninvasive and minimally-invasive optical monitoring technologies", J Nutr, 131(5), pp.1596~1604 (2001)
  19. R.A. Gabbay, "Optical coherence tomography- based continuous noninvasive glucose monitoring in patients with diabetes", Diabetes Technol Ther, 10(3), pp.188~193 (2008)
  20. K.V. Larin, "Noninvasive blood glucose monitoring with optical coherence tomography: a pilot study in human subjects", Diabetes Care, 25(12), pp.2263~2267 (2002)
  21. R. Rawer, "Polarimetric methods for measurement of intra ocular glucose concentration", Biomed Tech (Berl), 47(Suppl 1 Pt 1), pp.186~188 (2002)
  22. J. Sandby-Moller, "Influence of epidermal thickness, pigmentation and redness on skin autofluorescence", Photochem Photobiol, 77(6), pp.616~620 (2003)
  23. V.L. Alexeev, "Photonic crystal glucose-sensing material for noninvasive monitoring of glucose in tear fluid", Clin Chem, 50(12), pp.2353~2360 (2004)
  24. R. Badugu, "Wavelengthratiometric probes for the selective detection of fluoride based on the 6-aminoquinolinium nucleus and boronic acid moiety", J Fluoresc, 14(6), pp.693~703 (2004)
  25. B.S. Sekhon, "Chemical biology: past, present and future", Current Chemical Biology, 2(3), pp.278~311 (2008)
  26. R. Ballerstadt, "Concanavalin A for in vivo glucose sensing: a biotoxicity review", Biosens Bioelectron, 22(2), pp.275~284 (2006)
  27. V.M. Monnier, "Skin collagen glycation, glycoxidation, and crosslinking are lower in subjects with long-term intensive versus conventional therapy of type 1 diabetes: relevance of glycated collagen products versus HbA1c as markers of diabetic complications. DCCT Skin Collagen Ancillary Study Group. Diabetes Control and Complications Trial", Diabetes, 48(4), pp.870~880 (1999)
  28. M. Kohl, "The influence of glucose concentration upon the transport of light in tissue-simulating phantoms", Phys Med Biol, 40(7), pp.1267~1287 (1995)
  29. O. Amir, "Continuous noninvasive glucose monitoring technology based on "occlusion spectroscopy"", J Diabetes Sci Technol, 1(4), pp.463~469 (2007)
  30. R. Weiss, "Noninvasive continuous glucose monitoring using photoacoustic technology- results from the first 62 subjects", Diabetes Technol Ther, 9(1), pp.68~74 (2007)
  31. P. Glikfeld, "Noninvasive sampling of biological fluids by iontophoresis", Pharm Res, 6(11), pp.988~990 (1989)
  32. A. Caduff, "First human experiments with a novel non-invasive, non-optical continuous glucose monitoring system", Biosens Bioelectron, 19(3), pp.209~217 (2003)
  33. A. Tura, "Noninvasive glycaemia monitoring: background, traditional findings, and novelties in the recent clinical trials", Curr Opin Clin Nutr Metab Care, 11(5), pp.607~612 (2008)
  34. A. Pfutzner, "Impact of posture and fixation technique on impedance spectroscopy used for continuous and noninvasive glucose monitoring", Diabetes Technol Ther, 6(4), pp.435~441 (2004)
  35. D. Huber, "The compensation of perturbing temperature fluctuation in glucose monitoring technologies based on impedance spectroscopy", Med Biol Eng Comput, 45(9), pp.863~876 (2007)
  36. M. Gourzi, "Study of a new electromagnetic sensor for glycaemia measurement: in vitro results on blood pig", J Med Eng Technol, 27(6), pp.276~281 (2003)
  37. M. Gourzi, "Non-invasive glycaemia blood measurements by electromagnetic sensor: study in static and dynamic blood circulation", J Med Eng Technol, 29(1), pp.22~26 (2005)
  38. S. Gebhart, "Glucose sensing in transdermal body fluid collected under continuous vacuum pressure via micropores in the stratum corneum", Diabetes Technol Ther, 5(2), pp.159~166 (2003)
  39. J. Burdick, "Real-time glucose sensing using transdermal fluid under continuous vacuum pressure in children with type 1 diabetes", Diabetes Technol Ther, 7(3), pp.448~455 (2005)
  40. S. Mitragotri, "Analysis of ultrasonically extracted interstitial fluid as a predictor of blood glucose levels", J Appl Physiol, 89(3), pp.961~966 (2000)
  41. H. Chuang, "Clinical evaluation of a continuous minimally invasive glucose flux sensor placed over ultrasonically permeated skin", Diabetes Technol Ther, 6(1), pp.21~30 (2004)
  42. J. Kost, "Ultrasound-assisted insulin delivery and noninvasive glucose sensing", Diabetes Technol Ther, 4(4), pp.489~497 (2002)
  43. B.J. Novak, "Exhaled methyl nitrate as a noninvasive marker of hyperglycemia in type 1 diabetes", Proc Natl Acad Sci U S A, 104(40), pp.15613~15618 (2007)
  44. T.D. Minh, "Noninvasive measurement of plasma glucose from exhaled breath in healthy and type 1 diabetic subjects", Am J Physiol Endocrinol Metab, 300(6), pp.1166~1175 (2011)
  45. A. Caduff, "Characteristics of a multisensor system for non invasive glucose monitoring with external validation and prospective evaluation", Biosens Bioelectron, 26(9), pp.3794~3800 (2011)
  46. A. Caduff, "Non-invasive glucose monitoring in patients with Type 1 diabetes: a Multisensor system combining sensors for dielectric and optical characterisation of skin", Biosens Bioelectron, 24(9), pp.2778~2784 (2009)
  47. C. Turner, "Potential of breath and skin analysis for monitoring blood glucose concentration in diabetes", Expert Rev Mol Diagn, 11(5), pp.497~503 (2011)
  48. I. Harman-Boehm, "Noninvasive glucose monitoring: increasing accuracy by combination of multi-technology and multi-sensors", J Diabetes Sci Technol, 4(3), pp.583~595 (2010)
  49. I. Harman-Boehm, "Noninvasive glucose monitoring: a novel approach", J Diabetes Sci Technol, 3(2), pp.253~260 (2009)

관련 논문AI추천

이 간행물의 다른 논문 (6건)