As a means of managing diabetes, there is a need for a non-invasive glucose component measuring device. In this study, we investigated the possibility of measuring non-invasive glucose components using near-infrared spectroscopy. A measurement experiment was conducted by preparing a glucose component solution from 0% to 25% in 5% increments. The measured data was first represented by a graph of wavelength and optical measurements using Matlab. As a result, there was a section in which the optical measurement value for each concentration was highly reliable according to the wavelength. Thus, we selected a wavelength region with high measurement reliability and graph the glucose concentration and optical measurements using Matlab. As the glucose concentration increases, the absorption tends to increase and the reflectivity tends to decrease, so we find the possibility of measuring the glucose concentration using near-infrared spectroscopy.

Abstract

As a means of managing diabetes, there is a need for a non-invasive glucose component measuring device. In this study, we investigated the possibility of measuring non-invasive glucose components using near-infrared spectroscopy. A measurement experiment was conducted by preparing a glucose component solution from 0% to 25% in 5% increments. The measured data was first represented by a graph of wavelength and optical measurements using Matlab. As a result, there was a section in which the optical measurement value for each concentration was highly reliable according to the wavelength. Thus, we selected a wavelength region with high measurement reliability and graph the glucose concentration and optical measurements using Matlab. As the glucose concentration increases, the absorption tends to increase and the reflectivity tends to decrease, so we find the possibility of measuring the glucose concentration using near-infrared spectroscopy.

참고문헌 (15)

  1. KOSIS, "2017~2020 Statistics on the status of diabetics over 30s", ~ (2022)
  2. Kang N., , Yakhak Hoeji, 46(5), pp.331~336 (2002)
  3. Yumei Hu, , Biosensors and Bioelectronics, 48, pp.94~99 (2013)
  4. 유승엽, , The Magazine of the IEEK, 47(12), pp.867~873 (2020)
  5. Benjamin Freer, , 2010IEEE Antennas and Propagation Society International Symposium, pp.3214~3217 (2010)
  6. Karen H. Frith, , Nursing Education Perspectives, 43(4), pp.264~ (2022)
  7. Kim. J., , Electronics and Telecommunications Trends, 36(5), pp.9~20 (2021)
  8. Wilbert Villena Gonzales, , Sensors, 19(4), pp.800~844 (2019)
  9. G. L. Cote, , J Nutr, 131(5), pp.1596S~1604S (2001)
  10. Jun I. S., "Non-invasive blood sugar measurement method and device using optical reflectometry U.S. Patent No. 10779755", ~ (2020)
  11. Wilbert Villena Gonzales, , Sensors, 19(4), pp.800~844 (2019)
  12. Chang S. H., , ANALYTICAL SCIENCE & TECHNOLOGY, 11, pp.375~381 (1999)
  13. Chung H. -I., , ANALYTICAL SCIENCE & TECHNOLOGY, 13(1), pp.138~151 (2000)
  14. Kim H. J., , ANALYTICAL SCIENCE & TECHNOLOGY, 11, pp.47~53 (1997)
  15. Chang S. H., , ANALYTICAL SCIENCE & TECHNOLOGY, 11, pp.375~381 (1999)

관련 논문AI추천

이 간행물의 다른 논문 (7건)