Prospective, Comparative Evaluation of Forearm and Lower Leg Hair Removal with 808-nm Diode Laser at Different Fluences
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Background and Objectives High fluence diode lasers have emerged as the gold standard for removal of unwanted hair. Lowering the energy should result in less pain but could theoretically affect the efficacy of the therapy. The author designed this study to compare the efficacy of a low fluence 808-nm diode laser to that of a high fluence 808-nm diode laser for permanent hair removal in Korean women. Materials and Methods The author classified 26 Korean women into 2 groups. The groups received laser treatment for either the forearm or the lower leg using a low fluence HR808 prototype diode laser on one side and a high fluence laser on the other side at 1-month intervals. Hair counts and thickness were recorded by folliscope and photograph at each follow-up visit and at the 3-month follow-up after the final laser treatment. At the final visit, patients were surveyed regarding pain and satisfaction. Three plastic surgeons assessed the results by photograph. Results In the forearm group, the median reduction of hair density was 14.4% with low fluence and 19.0% with high fluence. The hair thickness reduction rate was 50% with low fluence and 65.6% with high fluence. Pain scores were 1.91 and 2.1, respectively. In the lower leg group, the median reduction of hair density was 45.9% with low fluence and 63.7% with high fluence. The hair thickness reduction rate was 57.7% with low fluence and 60.7% with high fluence. Pain scores were 2 and 2.4, respectively. Conclusion High fluence HR808 prototype diode laser can efficiently remove unwanted hair. In terms of treatment comfort, there was no significant difference compared to low fluence mode.
Abstract
Background and Objectives High fluence diode lasers have emerged as the gold standard for removal of unwanted hair. Lowering the energy should result in less pain but could theoretically affect the efficacy of the therapy. The author designed this study to compare the efficacy of a low fluence 808-nm diode laser to that of a high fluence 808-nm diode laser for permanent hair removal in Korean women. Materials and Methods The author classified 26 Korean women into 2 groups. The groups received laser treatment for either the forearm or the lower leg using a low fluence HR808 prototype diode laser on one side and a high fluence laser on the other side at 1-month intervals. Hair counts and thickness were recorded by folliscope and photograph at each follow-up visit and at the 3-month follow-up after the final laser treatment. At the final visit, patients were surveyed regarding pain and satisfaction. Three plastic surgeons assessed the results by photograph. Results In the forearm group, the median reduction of hair density was 14.4% with low fluence and 19.0% with high fluence. The hair thickness reduction rate was 50% with low fluence and 65.6% with high fluence. Pain scores were 1.91 and 2.1, respectively. In the lower leg group, the median reduction of hair density was 45.9% with low fluence and 63.7% with high fluence. The hair thickness reduction rate was 57.7% with low fluence and 60.7% with high fluence. Pain scores were 2 and 2.4, respectively. Conclusion High fluence HR808 prototype diode laser can efficiently remove unwanted hair. In terms of treatment comfort, there was no significant difference compared to low fluence mode.
참고문헌 (14)
- Gan SD, "Laser hair removal: a review", Dermatol Surg, 39, pp.823~838 (2013)
- Al-Haddab M, "The effect of waxing versus shaving on the efficacy of laser hair removal", Dermatol Surg, 43, pp.548~552 (2017)
- Alavi S, "Effects of hair removal alexandrite laser on biometric parameters of the skin", Lasers Med Sci, 31, pp.481~484 (2016)
- Ilknur T, "Effects of the 810-nm diode laser on hair and on the biophysical properties of skin", J Cosmet Laser Ther, 12, pp.269~275 (2010)
- Wheeland RG, "Permanent hair reduction with a home-use diode laser: safety and effectiveness 1 year after eight treatments", Lasers Surg Med, 44, pp.550~557 (2012)
- Wanitphakdeedecha R, "A split axilla comparison study of axillary hair removal with low fluence high repetition rate 810 nm diode laser vs. high fluence low repetition rate 1064 nm Nd:YAG laser", J Eur Acad Dermatol Venereol, 26, pp.1133~1136 (2012)
- Barolet D, "Low fluence-high repetition rate diode laser hair removal 12-month evaluation: reducing pain and risks while keeping clinical efficacy", Lasers Surg Med, 44, pp.277~281 (2012)
- Royo J, "Clinical assessment of a new 755 nm diode laser for hair removal: efficacy, safety and practicality in 56 patients", Lasers Surg Med, 49, pp.355~360 (2017)
- Brown M, "Permanent laser hair removal with low fluence high repetition rate 810 nm diode laser--a split leg comparison study", J Drugs Dermatol, 8S, pp.s14~s17 (2009)
- Pai GS, "Safety and efficacy of lowfluence, high-repetition rate versus high fluence, low repetition rate 810-nm diode laser for permanent hair removal--a splitface comparison study", J Cosmet Laser Ther, 13, pp.134~137 (2011)
- Koo B, "A comparison of two 810 diode lasers for hair removal: low fluence, multiple pass versus a high fluence, single pass technique", Lasers Surg Med, 46, pp.270~274 (2014)
- Agarwal M, "Efficacy of a low fluence, high repetition rate 810nm diode laser for permanent hair reduction in Indian patients with skin types IV-VI", J Clin Aesthet Dermatol, 9, pp.29~33 (2016)
- Li W, "Safety and efficacy of low fluence, high repetition rate versus high fluence, low repetition rate 810-nm diode laser for axillary hair removal in Chinese women", J Cosmet Laser Ther, 18, pp.393~396 (2016)
- Rogachefsky AS, "Evaluation of a new super-long-pulsed 810 nm diode laser for the removal of unwanted hair: the concept of thermal damage time", Dermatol Surg, 28, pp.410~414 (2002)
