For general radiological examinations, even in the same area and the same test, the test conditions must be set differently according to the patient. However, since it is impossible to consider the body shape and conditions of patients every time in medical institutions where various patients visit, the tests are conducted by setting the AEC which automatically sets the test conditions. AEC is most commonly used in chest radiography. Therefore, the purpose of this study is to propose the improvement plans for using AEC by measuring the exposure dose and evaluating the image quality according to whether the AEC is used or not, and to provide basic data for AEC research. In the present study, images were acquired while varying tube voltage and test distance according to the use of AEC in chest radiography. The radiation dose was measured by placing the dosimeter in front of the chest phantom, and the CNR and SNR of acquired images were analyzed using Image J. The t-test was conducted for the statistical analysis and the significance was determined at the level of 95%(p<.05). As a result of this study, in the inspection distance (100cm, 140cm, 180cm) according to the use of AEC, high doses were observed when the AEC was used and there was statistically significant difference( p<.05). In the t-test to determine the difference between CNR and SNR depending on whether AEC was used or not, there was no significant difference according to the use of AEC(p>.05). Therefore, when performing chest radiography, if the radiologist establishes the appropriate examination conditions and conducts the examination by not just relying solely on AEC, it may be possible to reduce unnecessary radiation exposure to the patient.
Abstract
For general radiological examinations, even in the same area and the same test, the test conditions must be set differently according to the patient. However, since it is impossible to consider the body shape and conditions of patients every time in medical institutions where various patients visit, the tests are conducted by setting the AEC which automatically sets the test conditions. AEC is most commonly used in chest radiography. Therefore, the purpose of this study is to propose the improvement plans for using AEC by measuring the exposure dose and evaluating the image quality according to whether the AEC is used or not, and to provide basic data for AEC research. In the present study, images were acquired while varying tube voltage and test distance according to the use of AEC in chest radiography. The radiation dose was measured by placing the dosimeter in front of the chest phantom, and the CNR and SNR of acquired images were analyzed using Image J. The t-test was conducted for the statistical analysis and the significance was determined at the level of 95%(p<.05). As a result of this study, in the inspection distance (100cm, 140cm, 180cm) according to the use of AEC, high doses were observed when the AEC was used and there was statistically significant difference( p<.05). In the t-test to determine the difference between CNR and SNR depending on whether AEC was used or not, there was no significant difference according to the use of AEC(p>.05). Therefore, when performing chest radiography, if the radiologist establishes the appropriate examination conditions and conducts the examination by not just relying solely on AEC, it may be possible to reduce unnecessary radiation exposure to the patient.
참고문헌 (11)
- 김창수, "디지털 방사선시스템에서 영상증강 파라미터의 영상특성 평가", 한국콘텐츠학회 논문지, 10(6), pp.329~335 (2010), 한국콘텐츠학회
- Ministry of Food and Drug Safety, "Guidelines for Standard Techniques in Imaging(general radiography)", ~ (2017)
- Sund P., "Comparison of visual grading analysis and determination of detective quantum efficiency for evaluating system performance in digital chest radiography", European Radiology, 14(1), pp.48~58 (2004)
- 정지상, "자동노출제어를 사용한 X선 흉부촬영에서 AEC 표지자 사용에 따른 환자 피폭선량 감소 효과", 방사선기술과학, 37(3), pp.177~185 (2014), 대한방사선과학회
- Veldkamp WJH, "Dose and Perceived image quality in chest radiography", European Journal of Radiology, 72(2), pp.209~217 (2009)
- 신성규, "디지털 방사선장비에서 자동노출제어 사용 시 환자피폭선량 감소 방안", 방사선기술과학, 36(2), pp.111~122 (2013), 대한방사선과학회
- 이진수, "디지털 흉부영상에서 자동노출제어 및 감도변화를 이용한 영상품질의 정량적인 평가", 한국콘텐츠학회 논문지, 13(8), pp.275~283 (2013), 한국콘텐츠학회[DOI]
- 김기홍, "방사선 자동 노출제어장치에 의한 피폭선량 변화 및 이미지 개선효과에 관한 연구", 석사, 전기공학, pp.2003
- 김은경, "진단용 디지털 영상장치의 조사조건 설정 실태 및 선량과 정도관리 인식에 관한 연구", 석사, 의학물리, pp.2011
- 김형일, "Sparse 표현을 이용한 X선 흡수 영상 개선", 멀티미디어학회논문지, 15(10), pp.1205~1211 (2012), 한국멀티미디어학회
- Ko SJ, "Introduction to Radiologic Science" (2013), Chungkoomoonwasa