이산화탄소 감지소자를 위한 마이크로볼로미터 구조 최적화 및 특성연구
Structure optimization and characterization of a microbolometer for a CO₂ detector
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this work, we optimized a microbolometer for application of a CO₂detector by using MEMS technology. Wefabricated a stable thermal isolation structure by varying the lengths of supporting legs which affect bolometerperformance. We could fabricate more stable thermal isolation structure for the microbolometer through the results ofANSYS simulations, and minimize the fabrication processes by using bulk micromachining to use a CO₂detector. Themicrobolometer shows a detectivity of 2.5×109 cmHz1/2/W at a chopper frequency of 8 Hz and a bias current of 6.25Awith a vacuum package of about 3.0×10-³ torr. Therefore, we put to conclusion that the microbolometer optimized inthis experiment could be useful for the application of a CO₂ detector.
Abstract
In this work, we optimized a microbolometer for application of a CO₂detector by using MEMS technology. Wefabricated a stable thermal isolation structure by varying the lengths of supporting legs which affect bolometerperformance. We could fabricate more stable thermal isolation structure for the microbolometer through the results ofANSYS simulations, and minimize the fabrication processes by using bulk micromachining to use a CO₂detector. Themicrobolometer shows a detectivity of 2.5×109 cmHz1/2/W at a chopper frequency of 8 Hz and a bias current of 6.25Awith a vacuum package of about 3.0×10-³ torr. Therefore, we put to conclusion that the microbolometer optimized inthis experiment could be useful for the application of a CO₂ detector.
참고문헌 (11)
- Joda Wormhoudt, "Infrared methods for gaseous measurements", Optica Acta, 33(9), pp.1095~1095 (1986)
- Currie, J.F., "Micromachined thin film solid state electgrochemical CO₂, NO₂, and SO₂gas sensors", Sensors and Actuators B Chemical, 59(2, pp.3) (1999), 235~241
- Andreas H., "Microfabrication techniques for chemical", biosensors, 2003, pp.91(6), ~
- Paul W. Kruse, "Uncooled infrared imaging arrays and systems" (1997), Academic press
- A.D. Parsons, "Thin-film infrared absorber structures for advanced thermal detectors", J. Vac. Sci. Technol. A, 6(3), pp.1686~1689 (1998)
- Nguyen chi-Anh, "Characterization of uncooled bolometer with vanadium tungsten oxide infrared active layer", Sensors and Actuators A, pp.123~124 (2005)
- Y-H Han, "Enhanced characteristics of an uncooled microbolometer using vanadium- tungsten oxide as a thermometric material", Applied Physics letters, 86 (2005)
- Nguyen Chi-Ahn, "Excess noise in vanadium tungsten oxide bolometric material", pp.38~41 (2007), Infrared Physics & Technology
- I.Y. Park, "Animplementation fo NDIR type CO₂ gas sample chamber and measuring hardware for capnograph system in consideration of the time response characteristics", J. Korean Sensors Soc, 10(5), pp.279~285 (2001)
- S-K Kim, "Application of mcirobolometer to integrated CO₂ sensor", Proc. of the International Sensors Conference (2004)
- G-J Lee, "The diaphragmstructure using the local surface etching for the improvement of sensitivity characteristics", J. Korean Sensors Soc, 13(4), pp.156~160 (2004)
