광섬유 방사선량계를 이용한 Co-60 방사선원으로부터 조사되는 상대선량측정

Measurement of relative dose irradiated from a Co-60 source using a scintillating fiber-optic dosimeter

1

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류공학일반

초록

In this study, we have fabricated a scintillating fiber-optic dosimeter for a radiotherapy dosimetry. And γ-rays generated by a Co-60 are measured using a scintillating fiber-optic dosimeter and percent depth dose curves are obtained according to the different depths of solid water phantoms. Also, Cerenkov radiations generated by primary or secondary electrons are measured at different depths of water phantom using a background optical fiber.

Abstract

In this study, we have fabricated a scintillating fiber-optic dosimeter for a radiotherapy dosimetry. And γ-rays generated by a Co-60 are measured using a scintillating fiber-optic dosimeter and percent depth dose curves are obtained according to the different depths of solid water phantoms. Also, Cerenkov radiations generated by primary or secondary electrons are measured at different depths of water phantom using a background optical fiber.

참고문헌 (10)

  1. A-M. Frelin, "Spectral discrimination of Cerenkov radiation in scintillating dosimeters", Med. Phys, 32, pp.3000~3006 (2005)
  2. T.O.White, "Scintillating fibers", Nucl. Instrum. Phys. Res. A, 273, pp.820~825 (1988)
  3. A.S.Beddar, "Plastic scintillation dosimetry and its application to radiotherapy", Radi. Meas, 41, pp.S124~S133 (2007)
  4. A. S. Beddar, "A miniature ‘Scintillator-Fiberoptic-PMT’ detector system for the dosimetry of small fields in stereotactic radiosurgery", IEEE Trans. Nucl. Sci.,, 48, pp.924~928 (2001)
  5. 신상훈, "유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의상대 깊이 선량율 측정", 센서학회지, 17(6), pp.462~469 (2008), 한국센서학회
  6. 조동현, "의료용 선형가속기의 X-선 분포도 측정을 위한 1차원 광섬유 방사선 센서의 제작 및 성능평가", 센서학회지, 16(1), pp.33~38 (2007), 한국센서학회
  7. L. Archambault, "Water-equivalent dosimeter array for small-field external beam radiotherapy", Med. Phys, 34, pp.1583~1592 (2007)
  8. B. Lee, "Measurements and characterizations of Cerenkov light in fiber-optic radiation sensor irradiated by high energy electron beam", Jpn. J. App. Phys, 45, pp.7980~7982 (2006)
  9. F. M. Khan, "he Physics of Radiation Therapy", pp.182~185 (1994), Williams & Wilkins
  10. W. R. Hendee, "Radiation Therapy Physics" (2005), Jhon Wiley & Sons

관련 논문AI추천

1차원 광섬유 팬텀선량계를 이용한 치료용 광자선의 피부 및 선량보강영역에서 상대선량 측정문진수, 박장연, 서정기, 유욱재, 이봉수, 장경원, 조영호한국센서학회 · 센서학회지2011 · 제20권 제2호고 에너지 X-선 조사에 의한 광섬유 방사선량계와 이온 전리함의 심부선량 백분율 측정 및 비교문주현, 박병기, 서정기, 유욱재, 이봉수, 장경원, 조동현, 조영호, 허지연한국센서학회 · 센서학회지2009 · 제18권 제2호유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의상대 깊이 선량율 측정김신, 문주현, 박병기, 서정기, 신상훈, 유욱재, 이봉수, 장경원, 조동현한국센서학회 · 센서학회지2008 · 제17권 제6호광섬유 방사선량계를 이용한 선량보강 영역에서의 심부선량 백분율과 피부 선량률 측정서정기, 유욱재, 이봉수, 장경원, 조동현, 조영호, 허지연한국광학회 · 한국광학회지2010 · 제21권 제1호광학 필터를 이용한 광섬유 방사선 센서의 체렌코프 빛 제거김신, 김형식, 이봉수, 이정한, 이정환, 장경원, 조동현, 조효성한국광학회 · 한국광학회지2006 · 제17권 제4호고 에너지 광자선 계측용 2차원 광섬유 방사선 센서의 제작 및 특성분석김신, 김형식, 신상훈, 이봉수, 이정한, 장경원, 조동현, 조효성한국광학회 · 한국광학회지2007 · 제18권 제4호

이 간행물의 다른 논문 (9건)