1차원 광섬유 팬텀선량계를 이용한 치료용 광자선의 피부 및 선량보강영역에서 상대선량 측정
Measurement of Relative Depth dose of Therapeutic Photon Beam Using One-Dimensional Fiber-Optic Phantom Dosimeter
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this study, we fabricated a fiber-optic phantom dosimeter by arraying square type of plastic optical fibers in a PMMA phantom for measuring relative depth doses of therapeutic photon beams. To minimize the cross-talk between fiber-optic dosimeters, we selected appropriate septum by measuring leaked scintillating lights according to the various kinds of septa. In addition, we measured percentage depth doses of 6, 15 MV photon beams using a fiber-optic phantom dosimeter.
Abstract
In this study, we fabricated a fiber-optic phantom dosimeter by arraying square type of plastic optical fibers in a PMMA phantom for measuring relative depth doses of therapeutic photon beams. To minimize the cross-talk between fiber-optic dosimeters, we selected appropriate septum by measuring leaked scintillating lights according to the various kinds of septa. In addition, we measured percentage depth doses of 6, 15 MV photon beams using a fiber-optic phantom dosimeter.
참고문헌 (16)
- F. M. Khan, "The Physics of Radiation Therapy", pp.323~332 (1984), Williams & Wilkims
- D. J. Manson, "Measurement of surface dose using build-up curve obtained with extrapolation chamber", Radiology, 115, pp.473~474 (1975)
- 장경원, "광섬유 방사선량계를 이용한 Co-60 방사선원으로부터 조사되는 상대선량측정", 센서학회지, 19(1), pp.52~57 (2010), 한국센서학회
- B. M. Rogina, "Application of optical fiber sensors for radiation dosimetry", Radiat. Meas, 26, pp.599~602 (1996)
- T. Aoyama, "vol.24", Med.Phys, 24, pp.1235~1239 (1997)
- M. J. Butson, "Measurement of radiotherapy superficial x-ray dose under eye shields with radiochromic film", Phys. Medica, 24, pp.29~33 (2008)
- 조동현, "고 에너지 X-선 조사에 의한 광섬유 방사선량계와 이온 전리함의 심부선량 백분율 측정 및 비교", 센서학회지, 18(2), pp.173~178 (2009), 한국센서학회
- K. W. Jang, "Development of Two-dimensional Fiber-optic Radiation Sensor for High Energy Photon Beam Therapy Dosimetry", JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 5, pp.466~469 (2008), ATOMIC ENERGY SOC JAPAN
- D. H. Cho, "Performance Evaluation of One-dimensional Fiber-optic Radiation Sensor for Measuring High Energy Electron Beam Using a Charge-coupled Device", Journal Of Nuclear Science And Technology, Supplement 5, pp.477~480 (2008), ATOMIC ENERGY SOC JAPAN
- D. Letoumeau, "Miniature scintillating detector for small field radiation therapy", Med. Phys, 26, pp.2555~2561 (1999)
- A. S. Beddar, "A miniature scintillator-fiberoptic-PMT detectorsystem for the dosimetry of small fields in streotacticradiosurgery", IEEE Trans. Nucl. Sci, 48, pp.924~928 (2001)
- L. Archambault, "vol.34", Med. Phys, 34, pp.1583~1592 (2007)
- A.S.Beddar, "Plastic scintillation dosimetry and its application to radiotherapy", Radiat. Meas, 41, pp.124~133 (2007)
- 조동현, "의료용 선형가속기의 X-선 분포도 측정을 위한 1차원 광섬유 방사선 센서의 제작 및 성능평가", 센서학회지, 16(1), pp.33~38 (2007), 한국센서학회
- V.B. Asgekar, "Theory of Cerenkov free electron lasers:An analytical treatment of saturation", Opt. Commun, 255, pp.309~313 (2005)
- M. Takiue, "Cerenkov counting of low-energy beta-emitters using a new ceramic with high refractive index", Appl. Radiat. Isot, 61, pp.1335~1337 (2004)
