본문 바로가기
KERD
논문KCI 등재

고 에너지 X-선 조사에 의한 광섬유 방사선량계와 이온 전리함의 심부선량 백분율 측정 및 비교

Measurements and comparisons of PDDs using ion chamber and fiber-optic dosimeter irradiated by high energy photon beam

0

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류공학일반

초록

In this study, we have fabricated a fiber-optic dosimeter using an organic scintillator and a plastic optical fiber for measuring percentage depth dose with high energy X-ray beam. The scintillating light generated in organic sensor probe embedded in a solid water are guided by 20 m plastic optical fiber to the light-measuring device such as a photodiode- amplifier system. Using a fiber-optic dosimeter and an ion chamber, percentage depth dose curves are measured with 6 and 15 MV energies of X-ray beam whose field sizes are 2 cm × 2 cm and 10 cm × 10 cm.

Abstract

In this study, we have fabricated a fiber-optic dosimeter using an organic scintillator and a plastic optical fiber for measuring percentage depth dose with high energy X-ray beam. The scintillating light generated in organic sensor probe embedded in a solid water are guided by 20 m plastic optical fiber to the light-measuring device such as a photodiode- amplifier system. Using a fiber-optic dosimeter and an ion chamber, percentage depth dose curves are measured with 6 and 15 MV energies of X-ray beam whose field sizes are 2 cm × 2 cm and 10 cm × 10 cm.

참고문헌 (14)

  1. B. M. Rogina, "Application of optical fiber sensors for radiation dosimetry", Radiation Measurements, 26(4), pp.599~602 (1996)
  2. T. Aoyama, "Depth-dose measuring device using a multichannel scintillating fiber array for electron beam therapy", pp.1235~1239 (1997), Nagoya University College of Medical Technology
  3. K. W. Jang, "Development of two-dimensional fiber-optic radiation sensor for high energy photon beam therapy dosimetry", J. Nuclear Science and Technology, 5, pp.466~469 (2008)
  4. D. H. Cho, "Performance evaluation of one-dimensional fiber-optic radiation sensor for measuring high energy electron beam using a cahrge-coupled device", J. Nuclear Science and Technology, 5, pp.477~480 (2008)
  5. I. Kwan, "Comparison of the New MOSkin Detector and Fiber Optic Dosimetry System for Radiotherapy", J. Nuclear Science and Technology, 5, pp.518~521 (2008)
  6. A. S. Beddar, "A miniature “scintillator-fiberoptic-PMT” detector system for the dosimetry of small fields in streotactic radiosurgery", IEEE Trans. Nucl. Sci., 48(3), pp.924~928 (2001)
  7. L. Archambault, "Water-equivalent dosimeter array for small-field external beam radiotherapy", Med. Phys, 34, pp.1583~ (2007)
  8. A. S. Beddar, "plastic scintillation dosimetry and its application to radiotherapy", Radiation Measurements, pp.S124~ (2007)
  9. 황영묵, "무기 섬광체를 이용한 플라스틱 광섬유 방사선 센서부 제작 및 특성평가", 센서학회지, 14(4), pp.244~249 (2005), 한국센서학회
  10. 조동현, "의료용 선형가속기의 X-선 분포도 측정을 위한 1차원 광섬유 방사선 센서의 제작 및 성능평가", 센서학회지, 16(1), pp.33~38 (2007), 한국센서학회
  11. W. R. Hendee, "Radiation therapy physics, 3rd ed", pp.130~ (2005), John Wiley & Sons, Inc.
  12. A. S. Beddar, "Water-equivallent plastic scintillation detectors for high-energy beam dosimetry: I. Physical characteristics and theoretical consideration", Phys. Med. Biol., 37, pp.1883~1900 (1992)
  13. A. S. Beddar, "Water-equivallent plastic scintillation detectors for high-energy beam dosimetry: II. Properties and measurements", Phys. Med. Biol., 37, pp.1901~1913 (1992)
  14. Faiz M. Khan, "The physics of radiation therapy, 2nd ed", pp.183~ (1994), Williams & Wilkins

관련 논문AI추천

광섬유 방사선량계를 이용한 선량보강 영역에서의 심부선량 백분율과 피부 선량률 측정서정기, 유욱재, 이봉수, 장경원, 조동현, 조영호, 허지연한국광학회 · 한국광학회지2010 · 제21권 제1호1차원 광섬유 팬텀선량계를 이용한 치료용 광자선의 피부 및 선량보강영역에서 상대선량 측정문진수, 박장연, 서정기, 유욱재, 이봉수, 장경원, 조영호한국센서학회 · 센서학회지2011 · 제20권 제2호고 에너지 광자선 계측용 2차원 광섬유 방사선 센서의 제작 및 특성분석김신, 김형식, 신상훈, 이봉수, 이정한, 장경원, 조동현, 조효성한국광학회 · 한국광학회지2007 · 제18권 제4호광섬유 방사선량계를 이용한 Co-60 방사선원으로부터 조사되는 상대선량측정김신, 박병기, 서정기, 신상훈, 유욱재, 이봉수, 장경원, 조동현, 허지연한국센서학회 · 센서학회지2010 · 제19권 제1호유기 섬광체-광섬유 방사선 센서를 이용한 근접 방사선원 Ir-192의상대 깊이 선량율 측정김신, 문주현, 박병기, 서정기, 신상훈, 유욱재, 이봉수, 장경원, 조동현한국센서학회 · 센서학회지2008 · 제17권 제6호의료용 선형가속기의 X-선 분포도 측정을 위한 1차원 광섬유 방사선 센서의 제작 및 성능평가김신, 유욱재, 이봉수, 장경원, 조동현, 조효성한국센서학회 · 센서학회지2007 · 제16권 제1호

이 간행물의 다른 논문 (12건)