Since MLC used in VMAT is a stepped shield, leakage dose may occur between theleaves. In this study, we compared the skin doses of VMAT treatment plan with Jaw Trackingapplied to CT image obtained using phantom and VMAT treatment technology plan withoutJaw Tracking, and confirmed the usefulness of Jaw Tracking method. We intend to present adirection that can reduce patient exposure due to leakage dose of MLC. As a result, when the JawTracking method was used, the skin dose was reduced by 2.00 cGy on average, and the skin dosewas reduced by 3% compared to the Fixed Jaw method. As a result, when using the Jaw Trackingmethod with VMAT, the leakage and transmission radiation generated between the MLCleaves are reduced, and radiation treatment with a protective effect on the skin is possible whencompared with the case using Fixed Jaw.

Abstract

Since MLC used in VMAT is a stepped shield, leakage dose may occur between theleaves. In this study, we compared the skin doses of VMAT treatment plan with Jaw Trackingapplied to CT image obtained using phantom and VMAT treatment technology plan withoutJaw Tracking, and confirmed the usefulness of Jaw Tracking method. We intend to present adirection that can reduce patient exposure due to leakage dose of MLC. As a result, when the JawTracking method was used, the skin dose was reduced by 2.00 cGy on average, and the skin dosewas reduced by 3% compared to the Fixed Jaw method. As a result, when using the Jaw Trackingmethod with VMAT, the leakage and transmission radiation generated between the MLCleaves are reduced, and radiation treatment with a protective effect on the skin is possible whencompared with the case using Fixed Jaw.

참고문헌 (15)

  1. 안용찬, "세기조절 방사선치료 기술의 소개", 대한의사협회지, 54(11), pp.1172~1178 (2011), 대한의사협회
  2. 장경환, "동적 세기조절방사선치료에서 깊이에 따른 DLG변화 분석", 의학물리, 26(3), pp.153~159 (2015), 한국의학물리학회[DOI]
  3. Feng Z, "Dosimetric comparison between jaw tracking and static jaw techniques in intensity-modulated radiotherapy", Radiat. Oncol, 10(28), pp.1~7 (2015)
  4. Jabbari K, "Dosimetry and evaluating the effect of treatment parameters on the leakage of multi leaf collimators in ONCOR linear accelerators", Adv. Biomed. Res, 5, pp.193~ (2016)
  5. Jang HJ, "A Study of useful treatment which uses dualenergy when treating lung-cancer patient with stereotactic body radiation therapy using Volumetric-modulated arctherapy(VMAT)", Journal of the Korean society of radiation therapy, 1(1), pp.1~44 (2015)
  6. 정재용, "선택적 최적화 변수(Selectable Optimization Parameters)에 따른 부피적조절회전방사선치료(VMAT)의 선량학적 영향", 의학물리, 23(1), pp.15~25 (2012), 한국의학물리학회[DOI]
  7. 김정남, "다엽콜리메이터의 임상적용을 위한 효율적인 정보 취득 기술", 한국콘텐츠학회 논문지, 8(11), pp.182~188 (2008), 한국콘텐츠학회
  8. Karthick Raj Mani, "Influence of jaw tracking in intensity-modulated and volumetric-modulated arc radiotherapy for head and neck cancers: a dosimetric study", Radiation oncology journal, 35(1), pp.90~100 (2017), 대한방사선종양학회
  9. Oh HT, "Effectiveness Assessment on Jaw-Tracking in Intensity Modulated Radiation Therapy and Volumetric ModulatedArc Therapy for Esophageal Cancer", Journal of the Korean Society of Radiation Therapy, 3(1), pp.33~41 (2019)
  10. Oh YK, "The Realization of Intensity-modulated Radiation Therapy Using the Liquid Shielding Material", Korean J. Med. Phys, 12(2), pp.155~160 (2001)
  11. Seungwoo Park, "A Study on Development and Usefulness of new Multi-Leaf Collimator for Diagnostic X-ray Equipment", Journal of Electrical Engineering & Technology, 13(2), pp.936~942 (2018), 대한전기학회
  12. Shim SH, "The Effect of Treatment for Radiation Skin Damage of Liver Stem Cells Originated from cord blood", Korean Association For Radiation Protection, 4, pp.74~75 (2011)
  13. 성지원, "RapidArc를 이용한 호흡연동 회전세기조절방사선치료 할 때전달선량의 정확성 평가", 의학물리, 24(2), pp.127~132 (2013), 한국의학물리학회
  14. Dose Reduction Guidelines in Radiotherapy- related Imaging, "Wang JH", Radiation Safety Management, ~, pp.Radiation Safety Management Series. No. 5 (2014)
  15. Wu H, "A comparative study of identical VMAT plans with and without technique", Journal of Applied Clinical Medical Physics, 17(5), pp.133~141 (2016)

관련 논문AI추천

체적조절호형방사선치료 시 갠트리 회전과 다엽콜리메이터의 이동 속도에 따른 선량분포 평가강동진, 김연래, 신영주, 이정우, 정재용, 정진범대한방사선과학회 · Journal of Radiological Science and Technology2019 · 제42권 제3호용적변조회전 방사선치료 시 Set-up 오차에 따른선량 전달 정확성의 평가김상현, 나권우, 박성아, 이주훈, 하광은(사)한국방사선산업학회 · 방사선산업학회지2018 · 제12권 제1호두경부 IMRT 및 VMAT 시 체적 감소가 전산화치료계획에 미치는 영향김가중, 백금문, 엄기천대한방사선과학회 · Journal of Radiological Science and Technology2023 · 제46권 제3호소프트웨어 기반 정도관리 시스템을 이용한 부피세기조절회전치료 환자 별 정도관리의 유용성 평가강동진, 권경태, 김연래, 민정환, 신영주, 정재용대한방사선과학회 · Journal of Radiological Science and Technology2018 · 제41권 제1호고에너지 엑스선의 선속평탄여과판이 조사야의 축이탈비 선량 변화에 미치는 영향곽종길, 김미현, 김성길, 동경래, 정묘영, 지연상(사)한국방사선산업학회 · 방사선산업학회지2019 · 제13권 제3호Evaluation of Beam-Matching Accuracy for 8 MV Photon Beam between the Same Model Linear Accelerator강성희, 김연래, 정진범대한방사선과학회 · Journal of Radiological Science and Technology2020 · 제43권 제2호

이 간행물의 다른 논문 (19건)