Physical and biological assessment of a novel resin for digital light processing
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
The current study introduces photocurable macromolecular resin (KIS resin) and aims to assess its use as a basic material for implant surgical stent fabrication using 3D printing and the digital light processing (DLP) technique. The biological and physical properties of KIS resin were evaluated, and radiological analysis was performed to assess the clinical accuracy of a 3D-printed surgical stent. The physical characteristics were analyzed in accordance with the guidelines of certified standards, and cell adhesion analysis was performed to evaluate the viability of human gingival fibroblast (hGF) cells exposed to KIS resin and conventional orthodontic acrylic resin. Radiological analysis of animals was carried out by pairwise overlap of pre- and postoperative images. The physical characteristics of KIS resin met the ISO 20795-1, ASTM D695, and ASTM D638 standards. The hGF cells on KIS resin samples exhibited better cell attachment and connection compared to those exposed to conventional resins. The findings of the radiological analyses showed statistically significant differences in the deviations between DLP-printed surgical stents and conventional stents, with the horizontal linear deviations being smaller in the coronal and middle levels of the former. Moreover, the angular deviation was also smaller in the DLP stent group. Therefore, KIS resin exhibited favorable physical properties and cell viability, highlighting its potential for use as a basic material for 3D-printed implant surgical guides. Further evaluation of the use of implant surgical stents fabricated using KIS resin and the DLP method as a proper tool for implant placement with clinical utility should be carried out.
Abstract
The current study introduces photocurable macromolecular resin (KIS resin) and aims to assess its use as a basic material for implant surgical stent fabrication using 3D printing and the digital light processing (DLP) technique. The biological and physical properties of KIS resin were evaluated, and radiological analysis was performed to assess the clinical accuracy of a 3D-printed surgical stent. The physical characteristics were analyzed in accordance with the guidelines of certified standards, and cell adhesion analysis was performed to evaluate the viability of human gingival fibroblast (hGF) cells exposed to KIS resin and conventional orthodontic acrylic resin. Radiological analysis of animals was carried out by pairwise overlap of pre- and postoperative images. The physical characteristics of KIS resin met the ISO 20795-1, ASTM D695, and ASTM D638 standards. The hGF cells on KIS resin samples exhibited better cell attachment and connection compared to those exposed to conventional resins. The findings of the radiological analyses showed statistically significant differences in the deviations between DLP-printed surgical stents and conventional stents, with the horizontal linear deviations being smaller in the coronal and middle levels of the former. Moreover, the angular deviation was also smaller in the DLP stent group. Therefore, KIS resin exhibited favorable physical properties and cell viability, highlighting its potential for use as a basic material for 3D-printed implant surgical guides. Further evaluation of the use of implant surgical stents fabricated using KIS resin and the DLP method as a proper tool for implant placement with clinical utility should be carried out.
참고문헌 (24)
- Hämmerle CH, "A systematic review of the survival of implants in bone sites augmented with barrier membranes (guided bone regeneration) in partially edentulous patients", J Clin Periodontol, 29(Suppl 3), pp.226~231 (2002)[DOI]
- Sarment DP, "Accuracy of implant placement with a stereolithographic surgical guide", Int J Oral Maxillofac Implants, 18, pp.571~577 (2003)
- Reyes A, "Accuracy of surgical guides made from conventional and a combination of digital scanning and rapid prototyping techniques", J Prosthet Dent, 113, pp.295~303 (2015)[DOI]
- 마보영, "The accuracy of a 3D printing surgical guide determined by CBCT and model analysis", The Journal of Advanced of Prosthodontics, 10(4), pp.279~285 (2018), 대한치과보철학회[DOI]
- Arisan V, "Accuracy of two stereolithographic guide systems for computer-aided implant placement : a computed tomography-based clinical comparative study", J Periodontol, 81, pp.43~51 (2010)[DOI]
- Quan H, "Photo-curing 3D printing technique and its challenges", Bioact Mater, 5, pp.110~115 (2020)[DOI]
- Nokar S, "Accuracy of implant placement using a CAD", CAM surgical guide : an in vitro study, 2011, pp.26, 520~526
- Gjelvold B, "Accuracy of surgical guides from 2 different desktop 3D printers for computed tomography-guided surgery", J Prosthet Dent, 121, pp.498~503 (2019)[DOI]
- Lee BA, "The effects of a novel botanical agent on lipopolysaccharide-induced alveolar bone loss in rats", J Periodontol, 84, pp.1221~1229 (2013)[DOI]
- Lee JH, "Surface characteristics and bioactivity of minocycline-treated Ti-6Al-4V alloy", pp.2016
- Valente F, "Accuracy of computeraided oral implant surgery : a clinical and radiographic study", Int J Oral Maxillofac Implants, 24, pp.234~242 (2009)
- Dizon J, "Mechanical characterization of 3D-printed polymers", Addit Manuf, 20, pp.44~67 (2018)[DOI]
- Arisan V, "Implant surgery using bone-and mucosa-supported stereolithographic guides in totally edentulous jaws : surgical and post-operative outcomes of computer-aided vs. standard techniques", Clin Oral Implants Res, 21, pp.980~988 (2010)[DOI]
- Rosenfeld AL, "Prosthetically directed implant placement using computer software to ensure precise placement and predictable prosthetic outcomes. Part 3 : stereolithographic drilling guides that do not require bone exposure and the immediate delivery of teeth", Int J Periodontics Restorative Dent, 26, pp.493~499 (2006)
- Jacobs P, "Rapid prototyping & manufacturing: fundamentals of stereolithography", pp.196~211 (1992), Society of Manufacturing Engineers
- Park SE, "Mechanical properties of surfacecharged poly(methyl methacrylate)as denture resins", Int J Dent, 2009, pp.841431~ (2009)[DOI]
- Aguirre BC, "Flexural strength of denture base acrylic resins processed by conventional and CAD-CAM methods", J Prosthet Dent, 123, pp.641~646 (2020)[DOI]
- Steinmassl PA, "Do CAD", CAM dentures really release less monomer than conventional dentures?, 2017, pp.21, 1697~1705
- Jorge JH, "Cytotoxicity of denture base acrylic resins : a literature review", J Prosthet Dent, 90, pp.190~193 (2003)[DOI]
- Van Landuyt KL, "How much do resin-based dental materials release? A meta-analytical approach", Dent Mater, 27, pp.723~747 (2011)[DOI]
- Proussaefs P, "Immediate provisionalization with a CAD", CAM interim abutment and crown : a guided soft tissue healing technique, 2015, pp.113, 91~95
- Souza IR, "Cytotoxicity of acrylic resin-based materials used to fabricate interim crowns", J Prosthet Dent, 124, pp.122~ (2020)[DOI]
- Naitoh M, "Can implants be correctly angulated based on surgical templates used for osseointegrated dental implants?", Clin Oral Implants Res, 11, pp.409~414 (2000)[DOI]
- Lin CC, "Fully digital workflow for planning static guided implant surgery : a prospective accuracy study", J Clin Med, 9, pp.980~ (2020)[DOI]