Effect of implant fixtures with blood pocket designed platforms on crestal bone

1

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

The purpose of this study was to investigate the impact of an implant with a blood pocket designed platform on the crestal bone by analyzing the stress distribution upon simulated application of occlusal forces and assessing its clinical role in marginal bone loss surrounding the implant. Stress exerted on the cortical and cancellous bones of three different platform type implants (URIS, TSIII, and Astra EV) were analyzed using finite element analysis (FEA). A load of 150 N was applied at 0°, 45°, and 90° angles to the long axis of each implant, and marginal bone loss in the implanted URIS fixtures (blood pocket designed platform) after immediate and delayed loading was measured. FEA showed that the stress generated on the fixture upon loading of the URIS implant was lower than that of the other two implants. The URIS implant also exerted the lowest stress on the cortical bone upon application of vertical pressure at an angle of 0° to the long axis of the fixture. The mean marginal bone loss in the alveolar bone was 1.01±0.33 mm and 0.46±0.30 mm upon immediate and delayed loading, respectively. FEA also indicated that implants with blood pocket designed platforms exhibited better stress distribution in the implant fixture and cortical bone under vertical pressure when compared to the fixtures of other designs. The marginal bone loss observed one year after loading of the URIS implant in the current study was lower than that reported previously.

Abstract

The purpose of this study was to investigate the impact of an implant with a blood pocket designed platform on the crestal bone by analyzing the stress distribution upon simulated application of occlusal forces and assessing its clinical role in marginal bone loss surrounding the implant. Stress exerted on the cortical and cancellous bones of three different platform type implants (URIS, TSIII, and Astra EV) were analyzed using finite element analysis (FEA). A load of 150 N was applied at 0°, 45°, and 90° angles to the long axis of each implant, and marginal bone loss in the implanted URIS fixtures (blood pocket designed platform) after immediate and delayed loading was measured. FEA showed that the stress generated on the fixture upon loading of the URIS implant was lower than that of the other two implants. The URIS implant also exerted the lowest stress on the cortical bone upon application of vertical pressure at an angle of 0° to the long axis of the fixture. The mean marginal bone loss in the alveolar bone was 1.01±0.33 mm and 0.46±0.30 mm upon immediate and delayed loading, respectively. FEA also indicated that implants with blood pocket designed platforms exhibited better stress distribution in the implant fixture and cortical bone under vertical pressure when compared to the fixtures of other designs. The marginal bone loss observed one year after loading of the URIS implant in the current study was lower than that reported previously.

참고문헌 (23)

  1. Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)[DOI]
  2. Smith DE, "Criteria for success of osseointegrated endosseous implants", J Prosthet Dent, 62, pp.567~572 (1989)[DOI]
  3. Zarb GA, "Consensus report : towards optimized treatment outcomes for dental implants", J Prosthet Dent, 80, pp.641~ (1998)[DOI]
  4. Albrektsson T, "The long-term efficacy of currently used dental implants : a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
  5. Hürzeler M, "Peri-implant bone level around implants with platform-switched abutments : preliminary data from a prospective study", J Oral Maxillofac Surg, 65(7 Suppl 1), pp.33~39 (2007)[DOI]
  6. Cappiello M, "Evaluation of peri-implant bone loss around platform-switched implants", Int J Periodontics Restorative Dent, 28, pp.347~355 (2008)
  7. Prendergast PJ, "Microdamage and osteocytelacuna strain in bone : a microstructural finite element analysis", J Biomech Eng, 118, pp.240~246 (1996)[DOI]
  8. Frost HM, "Wolff's Law and bone's structural adaptations to mechanical usage : an overview for clinicians", Angle Orthod, 64, pp.175~188 (1994)[DOI]
  9. 임정열, "임플란트 경부 디자인이 변연골 응력에 미치는 영향", 대한치과보철학회지, 48(03), pp.224~231 (2010), 대한치과보철학회[DOI]
  10. Schrotenboer J, "Effect of microthreads and platform switching on crestal bone stress levels : a finite element analysis", J Periodontol, 79, pp.2166~2172 (2008)[DOI]
  11. 정재민, "임플란트 경부형상이 주위골 응력에 미치는 영향에 관한 유한요소법적 분석", 대한치과보철학회지, 47(4), pp.394~405 (2009), 대한치과보철학회[DOI]
  12. Li YF, "Comparative and analysis study of peri-implant bone stress around Rescue implant and standard implant using finite element method", pp.2009
  13. Geng JP, "Application of finite element analysis in implant dentistry : a review of the literature", J Prosthet Dent, 85, pp.585~598 (2001)[DOI]
  14. Dávila E, "Crestal module design optimization of dental implants : finite element analysis and in vivo studies", J Mater Sci Mater Med, 30, pp.90~ (2019)[DOI]
  15. Patil YB, "Influence of implant neck design on crestal bone loss : a comparative study", Niger J Surg, 26, pp.22~27 (2020)[DOI]
  16. Lin D, "Mandibular bone remodeling induced by dental implant", J Biomech, 43, pp.287~293 (2010)[DOI]
  17. Marcián P, "Micro finite element analysis of dental implants under different loading conditions", Comput Biol Med, 96, pp.157~165 (2018)[DOI]
  18. Bozkaya D, "Evaluation of load transfer characteristics of five different implants in compact bone at different load levels by finite elements analysis", J Prosthet Dent, 92, pp.523~530 (2004)[DOI]
  19. Sykaras N, "Implant materials, designs, and surface topographies : their effect on osseointegration. A literature review", Int J Oral Maxillofac Implants, 15, pp.675~690 (2000)
  20. Al-Thobity AM, "Microthreaded implants and crestal bone loss : a systematic review", J Oral Implantol, 43, pp.157~166 (2017)[DOI]
  21. da Rocha Ferreira JJ, "Effect of crown-to-implant ratio and crown height space on marginal bone stress : a finite element analysis", Int J Implant Dent, 7, pp.81~ (2021)[DOI]
  22. Kim SY, "Factors associated with crestal bone loss following dental implant placement in a longitudinal follow-up study", J Oral Implantol, 41, pp.579~585 (2015)[DOI]
  23. Maló P, "Immediate function of Brånemark implants in the esthetic zone : a retrospective clinical study with 6 months to 4 years of follow-up", Clin Implant Dent Relat Res, 2, pp.138~146 (2000)[DOI]

관련 논문AI추천

Three-dimensional finite element analysis of platform switched implant권호범, 김명주, 문세영, 임영준대한치과보철학회 · The Journal of Advanced of Prosthodontics2017 · 제9권 제1호Finite element analysis of stress distribution around a short implant according to a horizontally reduced bone in the mandible김병옥, 김희중, 이원표, Kim Kyung-Min, Lim Kyeong-Ok, Yang Min-Cheol치의학연구원 · Oral Biology Research2021 · 제45권 제1호The effects of bone density and crestal cortical bone thickness on micromotion and peri-implant bone strain distribution in an immediately loaded implant: a nonlinear finite element analysisKazuhiko Yamamoto, Kazuhiro Murakami, Sadami Tsutsumi, Satoshi Horita, Tadaaki Kirita, Tsutomu Sugiura대한치주과학회 · Journal of Periodontal & Implant Science2016 · 제46권 제3호Effects of Coronal Thread Pitch in Scalloped Implant with 2 Different Connections on Loading Stress using 3 Dimensional Finite Element Analysis박성훈, 윤미정, 이재훈, 전영찬, 정창모, 최경수, 허중보대한턱관절교합학회 · 구강회복응용과학지2013 · 제29권 제2호Study of a “wing-type” implant on stress distribution and bone resorption at the alveolar crest박준우, 최동원, 최동주, 최미라, Jong-Wook Park, Sin-Guen Kim, Youn-Jin Yoon대한구강악안면외과학회 · 대한구강악안면외과학회지2012 · 제38권 제6호Marginal bone loss around crestal or subcrestal dental implants: prospective clinical studyHamidreza Arab, Hosein Hoseini Zarch, Mahdiye Fasihi Ramandi, Naser Sargolzaie, Tahereh Koohestani대한구강악안면외과학회 · 대한구강악안면외과학회지2022 · 제48권 제3호

이 간행물의 다른 논문 (5건)