본문 바로가기
KERD
논문KCI 등재

Comparing volumetric and biological aspects of 3D-printed interim restorations under various post-curing modes

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

초록

Purpose. This study aims to compare the volumetric change, degree of conversion (DOC), and cytotoxicity of 3D-printed restorations post-cured under three different conditions. Materials and Methods. 3D-printed interim restorations were post-cured under three different conditions and systems: 5 min, 30 min, and 24 h. Three-unit and six-unit fixed dental prostheses (n = 30 for each case) were printed; ten specimens from each group were post-cured and then scanned to compare their volumetric changes. Root-mean-squared (RMS) values of the data were acquired by superimposing the scanned files with original files. Thirty disk-shaped specimens were printed to evaluate the DOC ratio. Fourier transform infrared spectroscopy was used to compare the DOCs of 10 specimens from each group. Human gingival fibroblasts were used to measure the cell viability of every specimen (n = 7). The data from this experiment were employed for one-way analysis of variance and Tukey’s post-hoc comparisons. Results. Differences between the three-unit restorations were statistically insignificant, regardless of the post-curing conditions. However, for the six-unit restorations, a high RMS value was acquired when the post-curing duration was 30 min. The average DOC was approximately 56 - 62%; the difference between each group was statistically insignificant. All the groups exhibited cell viability greater than 70%, rendering them clinically acceptable. Conclusion . The post-curing conditions influenced the volume when the length of the restoration was increased. However, this deviation was found to be clinically acceptable. Additionally, postcuring did not significantly influence the DOC and cytotoxicity of the restorations.

Abstract

Purpose. This study aims to compare the volumetric change, degree of conversion (DOC), and cytotoxicity of 3D-printed restorations post-cured under three different conditions. Materials and Methods. 3D-printed interim restorations were post-cured under three different conditions and systems: 5 min, 30 min, and 24 h. Three-unit and six-unit fixed dental prostheses (n = 30 for each case) were printed; ten specimens from each group were post-cured and then scanned to compare their volumetric changes. Root-mean-squared (RMS) values of the data were acquired by superimposing the scanned files with original files. Thirty disk-shaped specimens were printed to evaluate the DOC ratio. Fourier transform infrared spectroscopy was used to compare the DOCs of 10 specimens from each group. Human gingival fibroblasts were used to measure the cell viability of every specimen (n = 7). The data from this experiment were employed for one-way analysis of variance and Tukey’s post-hoc comparisons. Results. Differences between the three-unit restorations were statistically insignificant, regardless of the post-curing conditions. However, for the six-unit restorations, a high RMS value was acquired when the post-curing duration was 30 min. The average DOC was approximately 56 - 62%; the difference between each group was statistically insignificant. All the groups exhibited cell viability greater than 70%, rendering them clinically acceptable. Conclusion . The post-curing conditions influenced the volume when the length of the restoration was increased. However, this deviation was found to be clinically acceptable. Additionally, postcuring did not significantly influence the DOC and cytotoxicity of the restorations.

참고문헌 (28)

  1. Dawood A, "3D printing in dentistry", Br Dent J, 219, pp.521~529 (2015)
  2. Abduo J, "Trends in computer-aided manufacturing in prosthodontics : a review of the available streams", Int J Dent, 2014, pp.783948~ (2014)
  3. Barazanchi A, "Additive technology : update on current materials and applications in dentistry", J Prosthodont, 26, pp.156~163 (2017)
  4. Quan H, "Photo-curing 3D printing technique and its challenges", Bioact Mater, 5, pp.110~115 (2020)
  5. Seime L, "Characterisation of LCD and DLP projection displays", Color Imaging Conf Final Progr Proc, pp.277~282 (2002)
  6. van Noort R, "The future of dental devices is digital", Dent Mater, 28, pp.3~12 (2012)
  7. McGurk M, "Rapid prototyping techniques for anatomical modelling in medicine", Ann R Coll Surg Engl, 79, pp.169~174 (1997)
  8. Tahayeri A, "3D printed versus conventionally cured provisional crown and bridge dental materials", Dent Mater, 34, pp.192~200 (2018)
  9. Taft RM, "Accuracy of rapid prototype models for head and neck reconstruction", J Prosthet Dent, 106, pp.399~408 (2011)
  10. Goodacre BJ, "Comparison of denture base adaptation between CAD-CAM and conventional fabrication techniques", J Prosthet Dent, 116, pp.249~256 (2016)
  11. Steinmassl O, "CAD", CAM produces dentures with improved fit, 2018, pp.22, 2829~2835
  12. Favero CS, "Effect of print layer height and printer type on the accuracy of 3-dimensional printed orthodontic models", Am J Orthod Dentofacial Orthop, 152, pp.557~565 (2017)
  13. Park SH, "The difference in degree of conversion between light-cured and additional heat-cured composites", Oper Dent, 21, pp.213~217 (1996)
  14. Susila AV, "Correlation of elution and sensitivity of cell lines to dental composites", Dent Mater, 32, pp.e63~e72 (2016)
  15. Samanidou VF, "A simple isocratic HPLC method for the simultaneous determination of the five most common residual monomers released from resin-based dental restorative materials", J Liq Chromatogr Relat Technol, 38, pp.740~749 (2015)
  16. Bourbia M, "Cariogenic bacteria degrade dental resin composites and adhesives", J Dent Res, 92, pp.989~994 (2013)
  17. Reymus M, "3D-printed material for temporary restorations : impact of print layer thickness and post-curing method on degree of conversion", Int J Comput Dent, 22, pp.231~237 (2019)
  18. Reymus M, "In vitro study on the influence of postpolymerization and aging on the Martens parameters of 3D-printed occlusal devices", J Prosthet Dent, 19 (2020)
  19. Kalberer N, "CAD-CAM milled versus rapidly prototyped(3D-printed)complete dentures : an in vitro evaluation of trueness", J Prosthet Dent, 121, pp.637~643 (2019)
  20. 강신영, "Accuracy of provisional crowns made using stereolithography apparatus and subtractive technique", The Journal of Advanced of Prosthodontics, 10(5), pp.354~360 (2018), 대한치과보철학회[DOI]
  21. Schaefer O, "Marginal and internal fit of pressed lithium disilicate partial crowns in vitro : a three-dimensional analysis of accuracy and reproducibility", Dent Mater, 28, pp.320~326 (2012)
  22. Leloup G, "Raman scattering determination of the depth of cure of light-activated composites : influence of different clinically relevant parameters", J Oral Rehabil, 29, pp.510~515 (2002)
  23. Lee BN, "Anti-inflammatory and osteogenic effects of calcium silicate-based root canal sealers", J Endod, 45, pp.73~78 (2019)
  24. Fuh J, "Processing and characterising photo-sensitive polymer in the rapid prototyping process", J Mater Process Technol, 89, pp.211~217 (1999)
  25. Piedra-Cascón W, "A vat-polymerized 3-dimensionally printed dual-material occlusal device : a dental technique", J Prosthet Dent (2020)
  26. Lin CH, "Mechanical properties, accuracy, and cytotoxicity of UV-polymerized 3D printing resins composed of Bis-EMA, UDMA, and TEGDMA", J Prosthet Dent, 123, pp.349~354 (2020)
  27. Reymus M, "Fracture load of 3D-printed fixed dental prostheses compared with milled and conventionally fabricated ones: the impact of resin material, build direction, post-curing, and artificial aging-an in vitro study", Clin Oral Investig, 24, pp.701~710 (2020)
  28. Par M, "The effect of rapid high-intensity light-curing on micromechanical properties of bulk-fill and conventional resin composites", Sci Rep, 10, pp.10560~ (2020)

관련 논문AI추천

Evaluating the accuracy (trueness and precision) of interim crowns manufactured using digital light processing according to post-curing time: An in vitro study김동연, 김지환, 유승규, 유승민, 이범일대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제2호Internal and marginal adaptation of 3D printed interim fixed partial dentures with different layer thicknessesAzam Sadat Mostafavi, Fateme Ghorbanpour Arani, Mahya Hasanzade, Negin Aminianpour대한치과보철학회 · The Journal of Advanced of Prosthodontics2025 · 제17권 제3호Assessment of effect of accelerated aging on interim fixed dental materials using digital technologiesAbdullah Alshehri, Fares Alhabbad, Haitham Almansour, Majed Alsarani, Omar Alageel, Omar Alsadon대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제6호Cellular responses to 3D-printed dental resins produced using a manufacturer recommended printer versus a third party printerAntónio Duarte da Mata, Beatriz Sona Cardoso, Joana Faria Marques, João Carlos Roque, João Paulo Martins, Mariana Brito da Cruz, Rodrigo Cordeiro Malheiro대한치과보철학회 · The Journal of Advanced of Prosthodontics2024 · 제16권 제2호Effect of rinsing time on the accuracy of interim crowns fabricated by digital light processing: An in vitro study강신영, 김지환, 유승규, 유승민, 이범일대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제1호Wear of 3D printed and CAD/CAM milled interim resin materials after chewing simulation안진수, 여인성, 윤형인, 이재현, 한중석, Gerelmaa Myagmar대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제3호

이 간행물의 다른 논문 (6건)