An on-die oscilloscope circuit is proposed to monitor the power noise waveforms inside IC due to the electrostatic discharge (ESD) events for a more complete analysis of the effects of the ESD on the electronic systems. When an ESD event occurs, the induced noise voltage waveform in the power supply is sampled and converted to digital data in real time. A holding signal created by the ESD detector circuit is used to hold the digital data. The stored digital data are read and converted back to the analog noise waveform based on the sampling process. The operation of each circuit block in the monitoring IC is analyzed and validated by measurement results. The delay between eight clock signals from the DLL is about 200ps for 620MHz input clock as expected. The power noise waveforms due to the ESD events are measured with a digital oscilloscope instrument using cables and directly sampled by the on-die oscilloscope with a sampling rate of 5GHz and 1.6GHz. These sampled noises are converted and reconstructed into analog noise waveforms, and then compared to the noises measured by the digital oscilloscope.
Abstract
An on-die oscilloscope circuit is proposed to monitor the power noise waveforms inside IC due to the electrostatic discharge (ESD) events for a more complete analysis of the effects of the ESD on the electronic systems. When an ESD event occurs, the induced noise voltage waveform in the power supply is sampled and converted to digital data in real time. A holding signal created by the ESD detector circuit is used to hold the digital data. The stored digital data are read and converted back to the analog noise waveform based on the sampling process. The operation of each circuit block in the monitoring IC is analyzed and validated by measurement results. The delay between eight clock signals from the DLL is about 200ps for 620MHz input clock as expected. The power noise waveforms due to the ESD events are measured with a digital oscilloscope instrument using cables and directly sampled by the on-die oscilloscope with a sampling rate of 5GHz and 1.6GHz. These sampled noises are converted and reconstructed into analog noise waveforms, and then compared to the noises measured by the digital oscilloscope.
참고문헌 (9)
- A. Talebzadeh, "Electrostatic charging caused by standing up from a chair and by garment removal", IEEE Symposium on Electromagnetic Compatibility and Signal Integrity, pp.57~62 (2015)
- "Road vehicles — Test methods for electrical disturbances from electrostatic discharge, ISO 10605 Ed. 2.0", ~ (2008)
- K. H. Kim, "Systematic analysis methodology for mobile phone's electrostatic discharge soft failures", IEEE Trans. Electromagn. Compat, 53(3), pp.611~661 (2011)
- T. Ostermann, "ESD induced EMS problems in digital IOs", Proc. IEEE Nordic Circuits Syst. Conf., NORCHIP Int. Symp. Syst.-on-Chip, pp.1~6 (2017)
- J. Zho, "Characterization of ESD risk for wearable devices", IEEE Trans. Electromagn. Compat, 60(5), pp.1313~1321 (2018)
- W. B. Kuhn, "ESD detection circuit and associated metal fuse investigations in CMOS processes", IEEE Trans. Device Mater. Rel, 14(1), pp.146~153 (2014)
- M. D. Ker, "On-chip transient detection circuit for system-level ESD protection in CMOS integrated circuits to meet electromagnetic compatibility regulation", IEEE Trans. Electromagn. Compat, 50(1), pp.13~21 (2008)
- M. D. Ker, "Transient-to-digital converter for system-level electrostatic discharge protection in CMOS ICs", IEEE Trans. Electromagn. Compat, 51(3), pp.620~630 (2009)
- W. Lee, "An On-die Oscilloscope for System-Level ESD Noise Monitoring", 2019 IEEE International Symposium on Electromagnetic Compatibility, Signal &Power Integrity (EMC+SIPI), pp.156~160 (2019)