Dentinal defects induced by 6 different endodontic files when used for oval root canals: an in vitro comparative study
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. “No defect” was defined as root dentin that presented with no visible microcracks or fractures. “Defect” was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.
Abstract
Objectives: To compare the formation of dentinal defects using stainless-steel hand K-files (HFs), rotary files, reciprocating files, and Self-Adjusting File (SAF), when used for oval root canals. Materials and Methods: One hundred and forty extracted human mandibular premolar with single root and oval canal were selected for this study. Oval canals were confirmed by exposing to mesio-distal and bucco-lingual radiographs. Teeth with open apices or anatomic irregularities were excluded. All selected teeth were de-coronated perpendicular to the long axis of the tooth, leaving roots segments approximately of 16 mm in length. Twenty teeth were left unprepared (control), and the remaining 120 teeth were divided into 6 groups (n = 20) and instrumented using HF (size 40/0.02), Revo-S (RS; size 40/0.06), ProTaper NEXT (PTN; size 40/0.06), WaveOne (WO; size 40/0.09), RECIPROC (RC; size 40/0.06), and the SAF (2 mm). Roots were then sectioned 3, 6, and 9 mm from the apex, and observed under stereomicroscope, for presence of dentinal defects. “No defect” was defined as root dentin that presented with no visible microcracks or fractures. “Defect” was defined by microcracks or fractures in the root dentin. Results: The control, HF, and SAF did not exhibit any dentinal defects. In roots instrumented by RS, PTN, WO, and RC files exhibited microcracks (incomplete or complete) in 40%, 30%, 55%, and 50%, respectively. Conclusions: The motor-driven root canal instrumentation with rotary and reciprocating files may create microcracks in radicular dentine, whereas the stainless-steel hand file instrumentation, and the SAF produce minimal or less cracks.
참고문헌 (21)
- Adl A, "The effect of using RC prep during root canal preparation on the incidence of dentinal defects", J Endod, 41, pp.376~379 (2015)
- Portenier I, "Preparation of the apical part of the root canal by the Lightspeed and step-back techniques", Int Endod J, 31, pp.103~111 (1998)
- Shemesh H, "The effects of canal preparation and filling on the incidence of dentinal defects", Int Endod J, 42, pp.208~213 (2009)
- Yoldas O, "Dentinal microcrack formation during root canal preparations by different NiTi rotary instruments and the self-adjusting file", J Endod, 38, pp.232~235 (2012)
- Barreto MS, "Vertical root fractures and dentin defects : effects of root canal preparation, filling, and mechanical cycling", J Endod, 38, pp.1135~1139 (2012)
- Bürklein S, "Incidence of dentinal defects after root canal preparation : reciprocating versus rotary instrumentation", J Endod, 39, pp.501~504 (2013)
- Shemesh H, "Damage to root dentin during retreatment procedures", J Endod, 37, pp.63~66 (2011)
- Pawar AM, "Assessment of the fracture resistance of teeth instrumented using 2 rotary and 2 reciprocating files versus the Self-Adjusting File(SAF) : an ex vivo comparative study on mandibular premolars", J Conserv Dent, 19, pp.138~142 (2016)
- Metzger Z, "The Self-Adjusting File(SAF)system : an evidence-based update", J Conserv Dent, 17, pp.401~419 (2014)
- Liu R, "The incidence of root microcracks caused by 3 different single-file systems versus the ProTaper system", J Endod, 39, pp.1054~1056 (2013)
- Ustun Y, "Cyclic fatigue and torsional resistance of two new nickel-titanium instruments used in reciprocation motion : Reciproc versus WaveOne", J Endod, 38, pp.541~544 (2012)
- Ustun Y, "The effects of different nickel-titanium instruments on dentinal microcrack formations during root canal preparation", Eur J Dent, 9, pp.41~46 (2015)
- Bürklein S, "Apically extruded debris with reciprocating single-file and full-sequence rotary instrumentation systems", J Endod, 38, pp.850~852 (2012)
- Wilcox LR, "The relationship of root canal enlargement to finger-spreader induced vertical root fracture", J Endod, 23, pp.533~534 (1997)
- Kim HC, "Potential relationship between design of nickel-titanium rotary instruments and vertical root fracture", J Endod, 36, pp.1195~1199 (2010)
- Kim HC, "Stress generation during self-adjusting file movement : minimally invasive instrumentation", J Endod, 39, pp.1572~1575 (2013)
- Metzger Z, "The self-adjusting file (SAF). Part 1: respecting the root canal anatomy--a new concept of endodontic files and its implementation", J Endod, 36, pp.679~690 (2010)
- Kim HC, "Mechanical response of nickel-titanium instruments with different cross-sectional designs during shaping of simulated curved canals", Int Endod J, 42, pp.593~602 (2009)
- Gergi RM, "Dentinal crack formation during root canal preparations by the twisted file adaptive, Reciproc and WaveOne instruments", Eur J Dent, 9, pp.508~512 (2015)
- You SY, "Shaping ability of reciprocating motion in curved root canals : a comparative study with micro-computed tomography", J Endod, 37, pp.1296~1300 (2011)
- Topcu KM, "Efficiency of the Self Adjusting File, WaveOne, Reciproc, ProTaper and hand files in root canal debridement", Eur J Dent, 8, pp.326~329 (2014)
