Effect of fluid contamination on reverse torque values in implant-abutment connections under oral conditions
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
Purpose. Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study aimed to examine the effects of blood, saliva, fluoride and chlorhexidine contamination on reverse torque values (RTVs) of abutment screws in oral conditions. Materials and Methods. 50 fixtures were mounted into the stainless-steel holders and divided into five groups (n = 10). Except control group (NC), fixture screw holes in other groups were contaminated with chlorhexidine (CG), saliva (SG), blood (BG), or fluoride (FG). Abutment screws were tightened with a digital torque meter. I/A assemblies were subjected to thermocycling and cyclic loading. The mean RTVs were recorded and data were analyzed with oneway ANOVA and Tukey test. Results. Except for specimens in SG (20.56 ± 1.33), other specimens in BG (21.11 ± 1.54), CG (22.89 ± 1.1) and FG (24.00 ± 1.12) displayed significantly higher RTVs compared to NC (19.00 ± 1.87). The highest RTVs were detected in CG and FG. Conclusion. The obtained data robustly suggest that RTVs were significantly affected by fluid contaminations. Specimens in FG and CG displayed the highest RTVs. Therefore, clinicians should have enough knowledge about probable contaminations in I/A interface in order to manage them during clinical procedure and to inform patients about using oral care products.
Abstract
Purpose. Implant mechanical complications, including screw loosening, can influence dental implant success. It has been shown that torque values are affected by contamination occurred in implant-abutment (I/A) interface. This study aimed to examine the effects of blood, saliva, fluoride and chlorhexidine contamination on reverse torque values (RTVs) of abutment screws in oral conditions. Materials and Methods. 50 fixtures were mounted into the stainless-steel holders and divided into five groups (n = 10). Except control group (NC), fixture screw holes in other groups were contaminated with chlorhexidine (CG), saliva (SG), blood (BG), or fluoride (FG). Abutment screws were tightened with a digital torque meter. I/A assemblies were subjected to thermocycling and cyclic loading. The mean RTVs were recorded and data were analyzed with oneway ANOVA and Tukey test. Results. Except for specimens in SG (20.56 ± 1.33), other specimens in BG (21.11 ± 1.54), CG (22.89 ± 1.1) and FG (24.00 ± 1.12) displayed significantly higher RTVs compared to NC (19.00 ± 1.87). The highest RTVs were detected in CG and FG. Conclusion. The obtained data robustly suggest that RTVs were significantly affected by fluid contaminations. Specimens in FG and CG displayed the highest RTVs. Therefore, clinicians should have enough knowledge about probable contaminations in I/A interface in order to manage them during clinical procedure and to inform patients about using oral care products.
참고문헌 (23)
- Ali Z, "Oral health-related quality of life after prosthodontic treatment for patients with partial edentulism : a systematic review and meta-analysis", J Prosthet Dent, 121, pp.59~68 (2019)
- Sargozaie N, "Comparing the quality of life of patients requesting dental implants before and after implant", Open Dent J, 11, pp.485~491 (2017)
- Goodacre CJ, "Clinical complications of osseointegrated implants", J Prosthet Dent, 81, pp.537~552 (1999)
- Lee HW, "The effect of contamination of implant screws on reverse torque", Int J Oral Maxillofac Implants, 30, pp.1054~1060 (2015)
- Tzenakis GK, "The effect of repeated torque and salivary contamination on the preload of slotted gold implant prosthetic screws", J Prosthet Dent, 88, pp.183~191 (2002)
- Tan KB, "The effect of 3 torque delivery systems on gold screw preload at the gold cylinder-abutment screw joint", Int J Oral Maxillofac Implants, 17, pp.175~183 (2002)
- Guda T, "Probabilistic analysis of preload in the abutment screw of a dental implant complex", J Prosthet Dent, 100, pp.183~193 (2008)
- Jörn D, "Influence of lubricant on screw preload and stresses in a finite element model for a dental implant", J Prosthet Dent, 112, pp.340~348 (2014)
- Guzaitis KL, "Effect of repeated screw joint closing and opening cycles on implant prosthetic screw reverse torque and implant and screw thread morphology", J Prosthet Dent, 106, pp.159~169 (2011)
- Cem Sahin, "Correlation between microleakage and screw loosening at implantabutment connection", The Journal of Advanced of Prosthodontics, 6(1), pp.35~38 (2014), 대한치과보철학회[DOI]
- Cardoso M, "Torque removal evaluation of prosthetic screws after tightening and loosening cycles : an in vitro study", Clin Oral Implants Res, 23, pp.475~480 (2012)
- Al Rafee MA, "The effect of repeated torque on the ultimate tensile strength of slotted gold prosthetic screws", J Prosthet Dent, 88, pp.176~182 (2002)
- Duarte AR, "Detorque evaluation of dental abutment screws after immersion in a fluoridated artificial saliva solution", J Prosthodont, 22, pp.275~281 (2013)
- Norton MR, "Assessment of cold welding properties of the internal conical interface of two commercially available implant systems", J Prosthet Dent, 81, pp.159~166 (1999)
- Ghanbarzadeh J, "Torque removal evaluation of one-piece and twopiece abutment screws under dry and wet conditions", J Mashad Dent Sch, 39, pp.89~98 (2015)
- Gumus HO, "Effect of fluid contamination on reverse torque values in bone-level implants", Implant Dent, 23, pp.582~587 (2014)
- Koosha S, "Effect of fluid contamination on the reverse torque values of abutment screws at implant-abutment connections", J Prosthet Dent, 123, pp.618~621 (2020)
- Micarelli C, "Implant abutment screw reverse torque values before and after plasma cleaning", Int J Prosthodont, 26, pp.331~333 (2013)
- Nigro F, "Removal torque of zirconia abutment screws under dry and wet conditions", Braz Dent J, 21, pp.225~228 (2010)
- Jalali H, "Effect of blood and saliva contamination of the implant-abutment interface on the amount of preload", Dentistry Adv Res, 3, pp.1~7 (2018)
- Kozlovsky A, "Interaction of chlorhexidine with smooth and rough types of titanium surfaces", J Periodontol, 77, pp.1194~1200 (2006)
- Zavanelli RA, "Corrosion-fatigue life of commercially pure titanium and Ti-6Al-4V alloys in different storage environments", J Prosthet Dent, 84, pp.274~279 (2000)
- Souza J, "Simultaneous degradation by corrosion and wear of titanium in artificial saliva containing fluorides", Wear, 292-3, pp.82~88 (2012)
