치과용 탄성 인상재를 기반으로 채득된 디지털 모형의 정확성연구: 3차원 중첩 분석
Accuracy of Digital Impression Made from Different Elastomeric Impression Materials: Three-Dimensional Superimpositional Analysis
2
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
The purpose of this study was to evaluate the accuracy of digitized elastomeric impression materials of crown abutment, using non-contact whitelight scanner and virtual three-dimensional superimpositional analysis. The stone models and impressions were digitized white light scanner tocreate three-dimensional surface models. Stone models were used as CAD reference model (CRM). The resulting point clouds (ASC file) fromdigitization of impressions using converting software. Discrepancies between the points in the point clouds and CRM were measured bysuperimpositional software. Mean and standard deviation of values of discrepancies were analyzed by one-way ANOVA and multiple comparison(α=0.05). The mean discrepancy between the impressions for the extra-light body (XLB), light body (LB), and heavy body (HB) group were5.10±1.45 μm, 6.30±1.87 μm, 9.80±1.52 μm, respectively. The different impression materials affected the digitization of impressionssignificantly (p<0.05). As a result, digitization of elastomeric impression materials on dental scanner was influenced by material sort.
Abstract
The purpose of this study was to evaluate the accuracy of digitized elastomeric impression materials of crown abutment, using non-contact whitelight scanner and virtual three-dimensional superimpositional analysis. The stone models and impressions were digitized white light scanner tocreate three-dimensional surface models. Stone models were used as CAD reference model (CRM). The resulting point clouds (ASC file) fromdigitization of impressions using converting software. Discrepancies between the points in the point clouds and CRM were measured bysuperimpositional software. Mean and standard deviation of values of discrepancies were analyzed by one-way ANOVA and multiple comparison(α=0.05). The mean discrepancy between the impressions for the extra-light body (XLB), light body (LB), and heavy body (HB) group were5.10±1.45 μm, 6.30±1.87 μm, 9.80±1.52 μm, respectively. The different impression materials affected the digitization of impressionssignificantly (p<0.05). As a result, digitization of elastomeric impression materials on dental scanner was influenced by material sort.
참고문헌 (22)
- Christensen GJ, "The state of fixed prosthodontics impressions:room for improvement", J Am Dent Assoc, 136, pp.343~346 (2005)
- Tinschert J, "Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD", CAM system, 2001, pp.26, 367~374
- Miyazaki T, "A review of dental CAD", CAM: current status and future perspectives from 20 years of experience, 2009, pp.28, 44~56
- Christensen GJ, "Impressions are changing: deciding on conventional, digital or digital plus in-office milling", J Am Dent Assoc, 140, pp.1301~1304 (2009)
- Luthardt RG, "Clinical parameters influencing the accuracy of 1- and 2-stage impressions: a randomized controlled trial", Int J Prosthodont, 21, pp.322~327 (2008)
- Rodriguez JM, "Surface roughness of impression materials and dental stones scanned by noncontacting laser profilometry", Dent Mater, 25, pp.500~505 (2009)
- Finger W, "Effect of mixing ratio on properties of elastomeric dental impression materials", Dent Mater, 2, pp.183~186 (1986)
- Shigeto N, "Evaluation of the methods for dislodging the impression tray affecting the dimensional accuracy of the abutments in complete dental arch cast", J Prothet Dent, 61, pp.54~58 (1989)
- Ciesco JN, "Comparison of elastomeric impression materials used in fixed prosthodontics", J Prothet Dent, 45, pp.89~94 (1981)
- Eames WB, "Accuracy and dimensional stability of elastomeric impression materials", J Prothet Dent, 42, pp.159~162 (1979)
- 김재홍, "인상 스캐닝 방법에 의해 제작된 디지털 치과 모형의 체적안정성 평가", 치위생과학회지, 14(1), pp.15~21 (2014), 한국치위생과학회
- Persson A, "Digitization of simulated clinical dental impressions: Virtual three-dimensional analysis of exactness", Dent Mater, 25, pp.929~936 (2009)
- Quaas S, "Direct mechanical data acquisition of dental impressions for the manufacturing of CAD", CAM restorations, 2007, pp.35, 903~908
- 이경탁, "치과용 스캐너로 채득한 디지털 모형의 반복성 및 재현성에 관한 3차원적 평가", 대한치과기공학회지, 34(3), pp.213~220 (2012), 대한치과기공학회
- Luthardt RG, "Accuracy of intraoral data acquisition in comparision to the conventional impression", Int J Comput Dent, 8, pp.283~294 (2005)
- Delong R, "Factors influencing optical 3D scanning of vinyl polysiloxane impression materials", J Prosthodont, 10, pp.78~85 (2001)
- Rekow ED, "High-technology innovations and limitations for restorative dentistry", Dent Clin North Am, 37, pp.513~524 (1993)
- Beuer F, "Digital dentistry: an overview of recent developments for CAD", CAM generated restorations, 2008, pp.204, 505~511
- Delong R, "Accuracy of a system for creating 3D computer models of dental arches", J Dent Res, 90, pp.434~440 (2003)
- Rudolph H, "Mathcing point clouds:limits and possibilities", Int J Comput Dent, 5, pp.155~164 (2002)
- Moldovan O, "Threedimensional fit of CAD", CAM-made zirconia copings, 2011, pp.27, 1273~1278
- Schaefer O, "Marginal and internal fit of pressed lithium disilicate partial crowns in vitro: a three-dimensional analysis of accuracy and reproducibility", Dent Mater, 28, pp.320~326 (2012)
