인상 스캐닝 방법에 의해 제작된 디지털 치과 모형의 체적안정성 평가
Evaluation of Dimensional Stability of Digital Dental Model Fabricated by Impression Scanning Method
2
조회
0
다운로드
12
인용
0
참고문헌
키워드
초록
The purpose of this study in vitro investigation was to evaluate the dimensional stability of dental digital models made by impression scanningmethod. Twenty working models were produced. Twenty impressions were made from study models. The dimensional stability of models of twogroups (stone and digital models) was examined using six landmark distances. Stone models were measured through digital vernier calipers. Digitalmodels were measured by the computer program. Statistical analyses were performed with Wilcoxon rank sum test (α=0.05). The mean of sixlandmark distances were significantly larger in the stone models than in the digital models (p<0.05) but digital models showed clinically acceptableaccuracy.
Abstract
The purpose of this study in vitro investigation was to evaluate the dimensional stability of dental digital models made by impression scanningmethod. Twenty working models were produced. Twenty impressions were made from study models. The dimensional stability of models of twogroups (stone and digital models) was examined using six landmark distances. Stone models were measured through digital vernier calipers. Digitalmodels were measured by the computer program. Statistical analyses were performed with Wilcoxon rank sum test (α=0.05). The mean of sixlandmark distances were significantly larger in the stone models than in the digital models (p<0.05) but digital models showed clinically acceptableaccuracy.
참고문헌 (24)
- Perakis N, "Final impression: a review of material properties and description of a current technique", Int J Periodontic Restor Dent, 24, pp.109~117 (2004)
- Wettstein F, "Clinical study of the internal gaps of zirconia and metal frameworks for fixed partial dentures", Eur J Oral Sci, 116, pp.272~279 (2008)
- Persson A, "Digitization of simulated clinical dental impressions: virtual three dimensional analysis of exactness", Dent Mater, 25, pp.929~936 (2009)
- Bolton WA, "Disharmony in tooth size and its relation to the analysis and treatment of malocclusion", Angle Orthod, 28, pp.113~130 (1958)
- McGuinness NJ, "Storage of orthodontic study models in hospital units in the U.K", Br J Orthod, 19, pp.227~232 (1992)
- Mah J, "Current status and future needs in craniofacial imaging", Orthod Craniofac Res, 6, pp.10~16 (2003)
- White AJ, "Analysis of intra-arch and interarch measurements from digital models with 2impression materials and a modeling process based on cone-beam computed tomography", Am J Orthod Dentofacial Orthop, 137, pp.456.e1~456.e9 (2010)
- Redlich M, "A new system for scanning, measuring, and analyzing dental casts based on a 3D holographic sensor", Orthod Craniofac Res, 11, pp.90~95 (2008)
- Leifert MF, "Comparison of space analysis evaluations with digital models and plaster dental casts", Am J Orthod Dentofacial Orthop, 136, pp.16.e1~16.e4 (2009)
- Dalstra M, "From alginate impressions to digital virtual models: accuracy and reproducibility", J Orthod, 36, pp.36~41 (2009)
- Christensen GJ, "The state of fixed prosthodontics impressions:room for improvement", J Am Dent Assoc, 136, pp.343~346 (2006)
- American Dental Association: Council on dental materals, "ANSI", ADA specification No. 25 for Dental Gypsum Products, 1987, pp.640~644
- Millstein PL, "Determining the accuracy of gypsum casts made from type Ⅳ dental stone", J Oral Rehabil, 19, pp.239~243 (1992)
- Custer F, "Accuracy and dimensional stability of a silicone rubber base impression material", J Prothet Dent, 14, pp.1115~1121 (1964)
- Creed B, "Comparison of the accuracy of linear measurement obtained from cone beam computerized tomography images and digital models", Semin Orthod, 17, pp.49~56 (2011)
- Lowey MN, "The development of a new method of cephalometric and study cast mensuration with a computer controlled, video image capture system. Part II: study cast mensuration", Br J Orthod, 20, pp.315~331 (1993)
- 김기백, "전악의 디지털 인상 채득 시 치과용 모형재가 디지털 모형 정확성에 미치는 영향", 치위생과학회지, 12(6), pp.617~623 (2012), 한국치위생과학회
- Bak SI, "The comparison between manual and 3D-digital measurement in dental cast measurements according to the degree of crowding", master, pp.2006
- Bell A, "Assessment of the accuracy of a three-dimensional imaging system for archiving dental study models", J Orthod, 30, pp.219~223 (2003)
- Santoro M, "Comparison of measurements made on digital and plaster models", Am J Orthod Dentofacial Orthop, 124, pp.101~105 (2003)
- Asquith J, "Three-dimensional imaging of orthodontic models: a pilot study", Eur J Orthod, 29, pp.517~522 (2007)
- Quimby ML, "The accuracy and reliability of measurements made on computerbased digital models", Angle Orthod, 74, pp.298~303 (2004)
- Bootvong K, "Virtual model analysis as an alternative approach to plaster model analysis: reliability and validity", Eur J Orthod, 23, pp.589~595 (2010)
- 김재홍, "도재 소성 과정에서의 고온이 지르코니아 코어의 변연적합도에 미치는 영향", 치위생과학회지, 13(2), pp.135~141 (2013), 한국치위생과학회