본문 바로가기
KERD
논문KCI 등재

Comparison of intraoral scanning and conventional impression techniques using 3-dimensional superimposition

2

조회

0

다운로드

5

인용

0

참고문헌

키워드

초록

PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The threedimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

Abstract

PURPOSE. The aim of this study is to evaluate the appropriate impression technique by analyzing the superimposition of 3D digital model for evaluating accuracy of conventional impression technique and digital impression. MATERIALS AND METHODS. Twenty-four patients who had no periodontitis or temporomandibular joint disease were selected for analysis. As a reference model, digital impressions with a digital impression system were performed. As a test models, for conventional impression dual-arch and full-arch, impression techniques utilizing addition type polyvinylsiloxane for fabrication of cast were applied. 3D laser scanner is used for scanning the cast. Each 3 pairs for 25 STL datasets were imported into the inspection software. The threedimensional differences were illustrated in a color-coded map. For three-dimensional quantitative analysis, 4 specified contact locations(buccal and lingual cusps of second premolar and molar) were established. For twodimensional quantitative analysis, the sectioning from buccal cusp to lingual cusp of second premolar and molar were acquired depending on the tooth axis. RESULTS. In color-coded map, the biggest difference between intraoral scanning and dual-arch impression was seen (P<.05). In three-dimensional analysis, the biggest difference was seen between intraoral scanning and dual-arch impression and the smallest difference was seen between dual-arch and full-arch impression. CONCLUSION. The two- and three-dimensional deviations between intraoral scanner and dual-arch impression was bigger than full-arch and dual-arch impression (P<.05). The second premolar showed significantly bigger three-dimensional deviations than the second molar in the three-dimensional deviations (P>.05).

참고문헌 (34)

  1. "The glossary of prosthodontic terms", J Prosthet Dent, 94, pp.10~92 (2005)
  2. Lee H, "The accuracy of implant impressions: a systematic review", J Prosthet Dent, 100, pp.285~291 (2008)
  3. Kan JY, "Clinical methods for evaluating implant framework fit", J Prosthet Dent, 81, pp.7~13 (1999)
  4. Cox JR, "The double arch impression technique: a solution to prevent supraocclusion in the indirect restoration", Gen Dent, 48, pp.86~91 (2000)
  5. Ceyhan JA, "The effect of tray selection, viscosity of impression material, and sequence of pour on the accuracy of dies made from dual-arch impressions", J Prosthet Dent, 90, pp.143~149 (2003)
  6. Ceyhan JA, "A clinical study comparing the three-dimensional accuracy of a working die generated from two dual-arch trays and a completearch custom tray", J Prosthet Dent, 90, pp.228~234 (2003)
  7. Hahn SM, "The effect of impression volume and double-arch trays on the registration of maximum intercuspation", J Prosthet Dent, 102, pp.362~367 (2009)
  8. Kang AH, "Accuracy of a reformulated fast-set vinyl polysiloxane impression material using dual-arch trays", J Prosthet Dent, 101, pp.332~341 (2009)
  9. Johnson GH, "Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays", J Prosthet Dent, 103, pp.13~22 (2010)
  10. Parker MH, "Comparison of occlusal contacts in maximum intercuspation for two impression techniques", J Prosthet Dent, 78, pp.255~259 (1997)
  11. Cox JR, "A clinical pilot study of the dimensional accuracy of double-arch and complete-arch impressions", J Prosthet Dent, 87, pp.510~515 (2002)
  12. Cox JR, "A clinical study comparing marginal and occlusal accuracy of crowns fabricated from double-arch and completearch impressions", Aust Dent J, 50, pp.90~94 (2005)
  13. Kaplowitz GJ, "Trouble-shooting dual arch impressions II", J Am Dent Assoc, 128, pp.1277~1281 (1997)
  14. Burke FJ, "A practice-based assessment of the handling of a fast-setting polyvinyl siloxane impression material used with the dual-arch tray technique", Quintessence Int, 32, pp.805~810 (2001)
  15. Christensen GJ, "Ensuring accuracy and predictability with double-arch impressions", J Am Dent Assoc, 139, pp.1123~1125 (2008)
  16. Johnson GH, "Clinical trial investigating success rates for polyether and vinyl polysiloxane impressions made with full-arch and dual-arch plastic trays", J Prosthet Dent, 103, pp.13~22 (2010)
  17. Patzelt SB, "Accuracy of full-arch scans using intraoral scanners", Clin Oral Investig, 18, pp.1687~1694 (2014)
  18. Touchstone A, "Digital transition: the collaboration between dentists and laboratory technicians on CAD", CAM restorations, 2010, pp.141, 15S~9S
  19. Miyazaki T, "CAD", CAM systems available for the fabrication of crown and bridge restorations, 2011, pp.56, 97~106
  20. 최호식, "CAD", CAM의 치과적 응용, 2012, pp.50(3), 110~117[DOI]
  21. Syrek A, "Clinical evaluation of all-ceramic crowns fabricated from intraoral digital impressions based on the principle of active wavefront sampling", J Dent, 38, pp.553~559 (2010)
  22. Güth JF, "Accuracy of digital models obtained by direct and indirect data capturing", Clin Oral Investig, 17, pp.1201~1208 (2013)
  23. Ting-Shu S, "Intraoral Digital Impression Technique: A Review", J Prosthodont, 24, pp.313~321 (2015)
  24. Ender A, "Accuracy of complete-arch dental impressions:a new method of measuring trueness and precision", J Prosthet Dent, 109, pp.121~128 (2013)
  25. Seelbach P, "Accuracy of digital and conventional impression techniques and workflow", Clin Oral Investig, 17, pp.1759~1764 (2013)
  26. Quaas S, "Direct mechanical data acquisition of dental impressions for the manufacturing of CAD", CAM restorations, 2007, pp.35, 903~908
  27. da Costa JB, "Evaluation of different methods of optical impression making on the marginal gap of onlays created with CEREC 3D", Oper Dent, 35, pp.324~329 (2010)
  28. Christensen GJ, "Will digital impressions eliminate the current problems with conventional impressions?", J Am Dent Assoc, 139, pp.761~763 (2008)
  29. Luthardt RG, "A new method for the computer-aided evaluation of three-dimensional changes in gypsum materials", Dent Mater, 19, pp.19~24 (2003)
  30. Price RB, "The dimensional accuracy of 12 impression material and die stone combinations", Int J Prosthodont, 4, pp.169~174 (1991)
  31. Giménez B, "Accuracy of a digital impression system based on parallel confocal laser technology for implants with consideration of operator experience and implant angulation and depth", Int J Oral Maxillofac Implants, 29, pp.853~862 (2014)
  32. Nedelcu RG, "Scanning accuracy and precision in 4 intraoral scanners: an in vitro comparison based on 3-dimensional analysis", J Prosthet Dent, 112, pp.1461~1471 (2014)
  33. Lee SJ, "Accuracy of digital versus conventional implant impressions", Clin Oral Implants Res, 26, pp.715~719 (2015)
  34. Stimmelmayr M, "Digital evaluation of the reproducibility of implant scanbody fit--an in vitro study", Clin Oral Investig, 16, pp.851~856 (2012)

관련 논문AI추천

Comparison of accuracy between digital and conventional implant impressions: two and three dimensional evaluationsChuang Bi, Fangfang Tian, Jiaming Zhao, Xingyu Wang, Zhe Qu대한치과보철학회 · The Journal of Advanced of Prosthodontics2022 · 제14권 제4호Comparison of 3D accuracy of three different digital intraoral scanners in full-arch implant impressionsFunda Bayindir, Ismail Hakki Korkmaz, Ozcan Akkal대한치과보철학회 · The Journal of Advanced of Prosthodontics2023 · 제15권 제4호Accuracy of intraoral scans of edentulous jaws with different generations of intraoral scanners compared to laboratory scansChristine Keul, Jan-Frederik Güth, Oliver Schubert, Panagiotis Kontis대한치과보철학회 · The Journal of Advanced of Prosthodontics2021 · 제13권 제5호Evaluation of different approaches for using a laser scanner in digitization of dental impressions김욱태, 김웅철, 김지환, 김혜영, 이완선대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제1호Comparison of the accuracy of digitally fabricated polyurethane model and conventional gypsum model김소연, 윤미정, 이소현, 전영찬, 정창모, 조승근, 허중보대한치과보철학회 · The Journal of Advanced of Prosthodontics2014 · 제6권 제1호Comparison of different impression techniques for edentulous jaws using three-dimensional analysis박찬, 박상원, 양홍서, 윤귀덕, 임현필, 정수아, Zhai Ying대한치과보철학회 · The Journal of Advanced of Prosthodontics2019 · 제11권 제3호

이 간행물의 다른 논문 (11건)