본문 바로가기
KERD
논문KCI 등재

스캐닝 방법에 따른 백색광 스캐너 기반으로 채득된 디지 털 모형의 정확성 비교

Comparison of the accuracy of digital models made from white light scanner by scanning method

1

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류치의학

초록

Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix , GC Industrial Corp, Japan) of master model were taken and type Ⅳ stone(aesthetic-base gold , Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad (Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.

Abstract

Objectives : The aim of this study was to determine the accuracy of digitized stone models, impression materials compared to the master model and the reliability of the computer aided analysis. Methods : A master model(500B-1, Nissin dental product, Japan) with the prepared lower full arch tooth was used. Ten vinyl polysiloxane impressions(Examix , GC Industrial Corp, Japan) of master model were taken and type Ⅳ stone(aesthetic-base gold , Dentona, Germany) were poured in stone models. The linear distance between the reference points were measured and analyzed on the Delcam Copycad (Delcam plc, UK). The t-student test for paired samples was used for statistical analysis. Results : The mean differences to master model for stone model and impression material were 0.11~0.19mm, and 0.19~0.29mm, respectively. There were statistical differences in dimensional accuracy for full arch impression between master model and stone model/impressions(p<.05). Conclusions : Two different scanning methods showed clinically acceptable accuracy of full arch digital impression produced by them. These results will have to be confirmed in further clinical studies.

참고문헌 (25)

  1. Tinschert J, "Marginal fit of alumina-and zirconia-based fixed partial dentures produced by a CAD", CAM system, 2001, pp.26(4), 367~374
  2. Miyazaki T, "A review of dental CAD", CAM: current status and future perspectives from 20 years of experience, 2009, pp.28(1), 44~56
  3. Christensen GJ, "Impressions are changing: deciding on conventional, digital or digital plus in-office milling", J Am Dent Assoc, 140(10), pp.1301~1304 (2009)
  4. Rekow ED, "High-technology innovations and limitations for restorative dentistry", Dent Clin North Am, 37(3), pp.513~524 (1993)
  5. Christensen GJ, "The state of fixed prosthodontics impressions: room for improvement", J Am Dent Assoc, 136(3), pp.343~346 (2006)
  6. Finger W, "Effect of mixing ratio on properties of elastomeric dental impression materials", Dent Mater, 2(4), pp.183~186 (1986)
  7. Shigeto N, "Evaluation of the methods for dislodging the impression tray affecting the dimensional accuracy of the abutments in complete dental arch cast", J Prothet Dent, 61(1), pp.54~58 (1989)
  8. Gerrow JD, "A comparison of the compatibility of elastomeric impression materials, type Ⅳ dental stones, and liquid media", J Prothet Dent, 57(3), pp.292~298 (1987)
  9. Ciesco JN, "Comparison of elastomeric impression materials used in fixed prosthodontics", J Prothet Dent, 45(1), pp.89~94 (1981)
  10. ADA specification No. 25 for Dental Gypsum Products, "Council on dental materals, ANSI", pp.1987, American Dental Association
  11. Millstein PL, "Determining the accuracy of gypsum casts made from type Ⅳ dental stone", J Oral Rehabil, 19(3), pp.239~243 (1992)
  12. Custer F, "Accuracy and dimensional stability of a silicone rubber base impression material", J Prothet Dent, 14(6), pp.1115~1121 (1964)
  13. Persson AS, "Digitization of simulated clinical dental impressions: Virtual three-dimensional analysis of exactness", Dent mater, 25(7), pp.929~936 (2009)
  14. Quaas S, "Direct mechanical data acquisition of dental impressions for the manufacturing of CAD", CAM restorations, 2007, pp.35(12), 903~908
  15. Creed B, "Comparison of the accuracy of linear measurement obtained from cone beam computerized tomography images and digital models", Semin Orthod, 17(2), pp.49~56 (2011)
  16. Delong R, "Accuracy of a system for creating 3D computer models of dental arches", J Dent Res, 82(6), pp.438~442 (2003)
  17. May KB, "Precision of fit: the Procera AllCeram crown", J Prosthet Dent, 80(4), pp.394~404 (1998)
  18. Mehl A, "A new optical 3D device for the detection of wear", J Dent Res, 76(11), pp.1799~1807 (1997)
  19. Beuer F, "Digital dentistry: an overview of recent developments for CAD", CAM generated restorations, 2008, pp.204(9), 505~511
  20. Kuroda T, "Three-dimensional dental cast analyzing system using laser scanning", Am J Orthod Dentofacial Orthop, 110(4), pp.365~369 (1996)
  21. Motohashi N, "A 3D computer-aided design system applied to diagnosis and treatment planning in orthodontics and orthognathic surgery", Eur J Orthod, 21(3), pp.263~274 (1999)
  22. Santoro M, "Comparison of measurements made on digital and plster models", Am J Orthod Dentofacial Orthop, 124(1), pp.101~105 (2003)
  23. Zilberman O, "Evaluation of the validity of tooth size and arch width measurements using conventional and three - dimensional virtual orthodontic models", Angle Orthod, 73(3), pp.301~306 (2003)
  24. Stevens DR, "Validity, reliability, and reproducibility of plaster vs digital study models: comparison of peer assessment rating and Bolton analysis and their constituent measurements", Am J Orthod Dentofacial Orthop, 129(6), pp.794~803 (2006)
  25. Quimby ML, "The accuracy and reliability of measurements made on computer-based digital models", Angle Orthod, 74(3), pp.298~303 (2004)

관련 논문AI추천