본문 바로가기
KERD
논문KCI 등재

맥 센서 어레이(array)의 실리콘(silicone) 코팅 두께에 따른 센서 간 간섭효과

Interference effects on the thickness of a pulse pressure sensor array coated with silicone

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

주제분류공학일반

초록

Pulse diagnosis is one of the representative diagnostic methods in Oriental medicine. In this study, a pulse pressure sensor array coated with silicone, which includes 6 piezo-resistive sensors and 1 thermistor, is fabricated for pulse measurement. It is necessary to coat the pulse sensor array with silicone to avoid the fracture or damage of pressure sensors when the sensor is in contact with the skin and a constant pressure is applied. However, the silicone coating on the pulse sensor array can cause signal interference among the sensors in the pulse sensor array. The interference number (IN), a calculation for expressing the degree of interference among channels, is changed according to the silicone thickness on the pulse sensor array. The IN is increased by a thick silicone coating, but the fabrication error, an important index for the mass production of the sensor array, is reduced by the thickness of the silicone coating. We propose that the thickness of the silicone on the pulse sensor array is an important consideration for the performance of the fabricated sensor and manufacturing repeatability.

Abstract

Pulse diagnosis is one of the representative diagnostic methods in Oriental medicine. In this study, a pulse pressure sensor array coated with silicone, which includes 6 piezo-resistive sensors and 1 thermistor, is fabricated for pulse measurement. It is necessary to coat the pulse sensor array with silicone to avoid the fracture or damage of pressure sensors when the sensor is in contact with the skin and a constant pressure is applied. However, the silicone coating on the pulse sensor array can cause signal interference among the sensors in the pulse sensor array. The interference number (IN), a calculation for expressing the degree of interference among channels, is changed according to the silicone thickness on the pulse sensor array. The IN is increased by a thick silicone coating, but the fabrication error, an important index for the mass production of the sensor array, is reduced by the thickness of the silicone coating. We propose that the thickness of the silicone on the pulse sensor array is an important consideration for the performance of the fabricated sensor and manufacturing repeatability.

참고문헌 (12)

  1. McLaughlin, J., "Piezoelectric sensor determination of arterial pulse wave velocity", Physiological Measurement, 24(3), pp.693~702 (2003)
  2. Pressman, G. L., "A transducer for the continuous external measurement of arterial blood pressure", Bio-medical Electronics, 10(2), pp.73~81 (1963)
  3. Kim, E. G., "Development of an Arterial Tonometer Sensor", Proceedings of Annual International Conference of the IEEE EMBS, pp.3771~3774 (2009)
  4. Shin, K. Y., "Development of the Sensor Module for a Radial Artery Tonometry", Proceedings of Conference of the IEEK, pp.1958~1959 (2010)
  5. Jeon, Y.J., "Design of Multi-Array Pulse Diagnosis Sensor with FDB Process", The Korean Institute of Electrical Engineers, Conference on Information and Control Systems, pp.367~368 (2008)
  6. Lee, S. S., "Measurement of blood pressure using an arterial pulsimeter equipped with a Hall device", Sensors, 11(2), pp.1784~1793 (2011)
  7. G. C. Kim, "A study on the waveform analysis of left kwan pulse diagnosis by the pressure", J Korea Inst. Orient. Med. Diagn, 13, pp.19~35 (2009)
  8. 김경철, "측정가압에 의한 左關 部位 맥파요인 변화에 대한 실험 연구", Korean Journal of Acupuncture, 27(4), pp.59~72 (2010), 경락경혈학회
  9. C. S. Hu, "Temporal and spatial properties of arterial pulsation measurement using pressure sensor array", Evidence-Based Complementary and Alternative Medicine, 2012 (2012)
  10. K. Y. Shin, "Finite Element Analysis of Packaging Shape Using PDMS for Pulse Diagnosis Sensor", Proceedings of Conference of the IEEK, pp.1709~1711 (2011)
  11. Yoo, S. K., "Development of a radial pulse tonometric(RPT)sensor with a temperature compensation mechanism", Sensors, 13(1), pp.611~625 (2013)
  12. Kim, J. U., "Differences in the Properties of the Radial Artery between Cun, Guan, Chi, and Nearby Segments Using Ultrasonographic Imaging:A Pilot Study on Arterial Depth, Diameter, and Blood Flow", Evidence-Based Complementary and Alternative Medicine, 2015 (2015)