맥진 깊이 판단을 위한 실시간 압력 측정기
Real-Time Pressure-Measuring System for Evaluating the Depth of Pulse
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In order to standardize the pressure/depth against radial artery, the externally-applied-pressure measuring system was fabricated and evaluated. Based on the resistance-variable characteristic of the very thin(10 ㎛) film conductive tape along the pressure of a tip of a examiner's hand, this system was designed. The change of the pressure was processed through voltage regulator and Matlab S/W, then showed on computer monitor. The signal output through voltage regulator, and Matlab S/W was evaluated on various conditions. The evaluation was executed on these cases; an examiner slowly increases and decreases the pressure, rapidly increases and decreases the pressure, sequentially increases and decreases the pressure, sustains the pressure, micro-changes the pressure. As a pulse examiner varies the pressure on the radial artery of the examinee, the system's real-time output consistently varies according to the pressure. From the results, it is concluded that this system consistently shows the pressure of the tip of a examiner's hand in real time without interrupting the evaluation of the radial artery pulse. Therefore this system is expected to standardize the value of the pressure/depth externally applied by an examiner.
Abstract
In order to standardize the pressure/depth against radial artery, the externally-applied-pressure measuring system was fabricated and evaluated. Based on the resistance-variable characteristic of the very thin(10 ㎛) film conductive tape along the pressure of a tip of a examiner's hand, this system was designed. The change of the pressure was processed through voltage regulator and Matlab S/W, then showed on computer monitor. The signal output through voltage regulator, and Matlab S/W was evaluated on various conditions. The evaluation was executed on these cases; an examiner slowly increases and decreases the pressure, rapidly increases and decreases the pressure, sequentially increases and decreases the pressure, sustains the pressure, micro-changes the pressure. As a pulse examiner varies the pressure on the radial artery of the examinee, the system's real-time output consistently varies according to the pressure. From the results, it is concluded that this system consistently shows the pressure of the tip of a examiner's hand in real time without interrupting the evaluation of the radial artery pulse. Therefore this system is expected to standardize the value of the pressure/depth externally applied by an examiner.
참고문헌 (7)
- 임양근, "맥진(진단학 아틀라스3)", pp.11~12 (2003), 도서출판 정담
- 홍성천, "한방의료정보화 현황 및 발전방안에 관한 연구", 대한한의정보학회지, 10(2), pp.114~188 (2004)
- Hyunho Kim, "Development of pulse diagnostic devices in Korea", Integrative Medicine Research, 2, pp.7~17 (2013)
- 金鍾悅, "맥진기의 문제점과 개선방안에 관한 연구", 대한한의진단학회지, 3(1), pp.28~36 (1999)
- 김경철, "脈診의 현대적인 객관화 연구를 위한 기반조사 - Ⅰ. 기계적 측정법에 대한 비교연구 -", 동의생리병리학회지, 17(5), pp.1147~1150 (2003), 대한동의병리학회
- Rayburn, Ray A., "Eargle's The Microphone Book", pp.112~114 (2011), Elsevier
- 이향숙, "팔체질의학 맥진의 신뢰성 연구", 대한경락경혈학회지, 22(4), pp.1~8 (2005)