압전 필름과 전도성 섬유를 이용한 맥파 전달 속도 측정을 위한 센서의 제작 및 성능평가

Fabrication and Evaluation of Sensor for Measuring Pulse Wave Velocity using Piezo Film and Conductive Textile

2

조회

0

다운로드

4

인용

0

참고문헌

키워드

주제분류공학일반

초록

Arterial stiffness is causing the serious problems for human who is suffered from hypertension and metabolic syndrome. So it is important that measure the arterial stiffness for early prevention. Many researches point out that pulse wave velocity(PWV) is the reliable and simple method to predict arterial stiffness. In this paper, we developed the sensing parts that detect the pulse wave and ECG by using piezoelectric film and conductive textile with elastic band. Our system could detect 3ch pulse wave and ECG. Simultaneously, our algorithm extracts the features for calculating the delays among pulse waves. The delays are the significant parameter to estimate PWV, thus we design the experiment for evaluating the performance of our sensing parts. The reference is PP-1000(HanByul Meditech, Korea) that is good for performance evaluation. As a result, the start point of the pulse wave was the most reliable feature for comparing with PP-1000(r=0.691, P=0.00). The results between two operators showed that there is only a slight difference in the reproducibility of the devices. In conclusion, we assume that the suggested sensor could be more comfortable and faithful method for arterial stiffness.

Abstract

Arterial stiffness is causing the serious problems for human who is suffered from hypertension and metabolic syndrome. So it is important that measure the arterial stiffness for early prevention. Many researches point out that pulse wave velocity(PWV) is the reliable and simple method to predict arterial stiffness. In this paper, we developed the sensing parts that detect the pulse wave and ECG by using piezoelectric film and conductive textile with elastic band. Our system could detect 3ch pulse wave and ECG. Simultaneously, our algorithm extracts the features for calculating the delays among pulse waves. The delays are the significant parameter to estimate PWV, thus we design the experiment for evaluating the performance of our sensing parts. The reference is PP-1000(HanByul Meditech, Korea) that is good for performance evaluation. As a result, the start point of the pulse wave was the most reliable feature for comparing with PP-1000(r=0.691, P=0.00). The results between two operators showed that there is only a slight difference in the reproducibility of the devices. In conclusion, we assume that the suggested sensor could be more comfortable and faithful method for arterial stiffness.

참고문헌 (19)

  1. Safar ME, "Hypertension and the arterial system: Clinical and therapeutic aspects", J. Hypertension, 8(7), pp.113~119 (1990)
  2. Bader H, "Importance of the gerontology of elastic arteries in the development of essential hypertension", Clin Physiol Biochem, (1), pp.36~56 (1983)
  3. Frank O, "Die grundform des arteriellen pulses", Z Biol, 37, pp.483~526 (1899)
  4. Johnson CP, "Age related changes in the tunica media of the vertebral artery: implications for the assessment of vessels injured by trauma", J. Clin Pathol., 54, pp.139~145 (2001)
  5. Hanna-Maaria Lakka, "The metabolic syndrome and total and cardiovascular disease mortality in middle-aged men", The Journal of the American Medical Association, 288(22), pp.2709~2716 (2002)
  6. C. D. A. Stehouwer, "Arterial stiffness in diabetes and the metabolic syndrome: a pathway to cardiovascular disease", Diabetologia, 51(4), pp.527~539 (2008)
  7. Stephane Laurent, "Expert consensus document on arterial stiffness: methodological issues and clinical applications", European Heart Journal, 27(21), pp.2588~2605 (2006)
  8. Measurement Specialties, "Piezo Film Sensor Technical Manual", Measurement Specialties Inc., ~ (2006)
  9. Gruetzmann Anna, "Novel dry electrodes for ECG monitoring", Physiological Measurement, 28(11), pp.1375~1390 (2007)
  10. Bert-Uwe Köhler, "The principles of software QRS detection", IEEE Engineering in Medicine and Biology Magazine, 22(1), pp.42~57 (2002)
  11. Y. Christopher Chiu, "Determination of pulse wave velocities with computerized algorithms", American Heart Journal, 121(5), pp.1460~1470 (1991)
  12. Masanori Munakata, "Utility of automated brachial ankle pulse wave velocity measurements in hypertensive patients", American Journal of Hypertension, 16(8), pp.653~657 (2003)
  13. Roland Asmar, "Assessment of arterial distensibility by automatic pulse wave velocity measurement", Hypertensions, 26(3), pp.485~490 (1995)
  14. Park, Jong Suk, "Insulin resistance independently influences arterial stiffness in normoglycemic normotensive postmenopausal women", Menopause, 17(4), pp.779~784 (2010)
  15. J.S. Nam, "The association between pulse wave velocity and metabolic syndrome and adiponectin in patients with impaired fasting glucose: Cardiovascular risks and adiponectin in IFG", Diabetes Research and Clinical Practice, 84(2), pp.145~151, ELSEVIER
  16. C. Fabrizio, "A piezo-film-based measurement system for global haemodynamic assessment", Physiological Measurement, 31(5), pp.697~714 (2010)
  17. 최정현, "맥파 전달 속도(PWV) 측정을 위한 특징점 검출 알고리즘 개발", 센서학회지, 20(5), pp.343~350 (2011), 한국센서학회
  18. 정상중, "u-Health 서비스 지원을 위한 착용형 옥시미터를 이용한 맥파 분석 시스템", 센서학회지, 19(1), pp.17~24 (2010), 한국센서학회
  19. 이낙범, "Reproducibility of Regional Pulse Wave Velocity in Healthy Subjects", The Korean Journal of Internal Medicine, 24(1), pp.19~23 (2009), 대한내과학회

이 간행물의 다른 논문 (11건)