손목 피부 온도에 의한 맥센서 어레이(array)의 신호 변동 및 보정

Signal Change and Compensation of Pulse Pressure Sensor Array Due to Wrist Surface Temperature

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류공학일반

초록

A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperaturesensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuringpulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at 35°C (the maximum wrist temperature), thedevice was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sen-sor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during tem- perature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect tothickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the com-pensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.

Abstract

A pressure sensor in pulse measurement system is a core component for precisely measuring the pulse waveform of radial artery. A pulse sensor signal that measures the pulse wave in contact with the skin is affected by the temperature difference between the ambient temperature and skin surface. In this study, we found experimentally that the signal changes of the pressure sensors and a temperaturesensor were caused by the temperature of the wrist surface while the pressure sensor was contacted on the skin surface for measuringpulse wave. To observe the signal change of the pulse sensor caused by temperature increase on sensor surface, Peltier device that can be kept at a set temperature was used. As the temperature of Peltier device was kept at 35°C (the maximum wrist temperature), thedevice was put on the pulse sensor surface. The temperature and pressure signals were obtained simultaneously from a temperature sen-sor and six pressure sensors embedded in the pulse sensor. As a result of signal analysis, the sensor pressure was decreased during tem- perature increase of pulse sensor surface. In addition, the signal difference ratio of pressure and temperature sensors with respect tothickness of cover layer in pulse sensor was increased exponentially. Therefore, the signal of pressure sensor was modified by the com-pensation equation derived by the temperature sensor signal. We suggested that the thickness of cover layer in pulse sensor should be designed considering the skin surface temperature.

참고문헌 (13)

  1. Jun, M. H., "Development of a Tonometric Sensor with a Decoupled Circular Array for Precisely Measuring Radial Artery Pulse", Sensors, 16(6) (2016)
  2. Wang, D. M., "A Novel Multichannel Wrist Pulse System With Different Sensor Arrays", IEEE Trans. Instrum. Meas, 64(7), pp.2020~2034 (2015)
  3. Joshi, A. B., "Simulations of piezoelectric pressure sensor for radial artery pulse measurement", Mater. Sci. Eng. B Solid State Mater. Adv. Technol, 168(1-3), pp.250~253 (2010)
  4. C. S. Hu, "Temporal and spatial properties of arterial pulsation measurement using pressure sensor array", Evid. Based Complement Alternat. Med, 2012, pp.9~ (2012)
  5. 이상석, "A New Measurement Method of a Radial Pulse Wave Using Multiple Hall Array Devices", Journal of Magnetics, 14(3), pp.132~136 (2009), 한국자기학회
  6. McLaughlin, J., "Piezoelectric sensor determination of arterial pulse wave velocity", Physiol. Meas, 24(3), pp.693~702 (2003)
  7. Pressman, G. L, "A transducer for the continuous external measurement of arterial blood pressure", IEEE Trans. Biomed. Eng, 10(2), pp.73~81 (1963)
  8. Yu-Wen Chu, "Using an array sensor to determine differences in pulse diagnosis—Three positions and nine indicators", Eur. J. Integr. Med, 6(5), pp.516~523 (2014)
  9. 김영민, "맥 센서 어레이(array)의 실리콘(silicone) 코팅 두께에 따른 센서 간 간섭효과", 센서학회지, 25(1), pp.35~40 (2016), 한국센서학회
  10. Yoo, S. K., "Development of a radial pulse tonometric (RPT) sensor with a temperature compensation mechanism", Sensors, 13(1), pp.611~625 (2013)
  11. J. A. Sarabia, "Circadian rhythm of wrist temperature in normal-living subjects : A candidate of new index of the circadian system", Physiol. Behav, 95(4), pp.570~580 (2008)
  12. Martinez-Nicolas A, "Uncovering different masking factors on wrist skin temperature rhythm in free-living subjects", PloS One, 8(4), pp.e61142~ (2013)

관련 논문AI추천

이 간행물의 다른 논문 (11건)