본문 바로가기
KERD
논문KCI 등재

수평설치조건의 건물부착형 태양광발전시스템에 대한 장기 운영 성능평가

Assessment of Long-Term Operational Performance of Building Attached PV System Installed on Horizontal Plane

2

조회

0

다운로드

1

인용

0

참고문헌

키워드

주제분류기타공학

초록

Regulations and certification systems have been installed in many building-applied renewable energy systems (BARESs). Efforts to investigate and maintain the performance of renewable energy systems (RESs) have been lacking from the perspective of users or facility managers. This maintenance issue has obstructed the RES from operating in terms of its original purpose. Therefore, in this study, the operation status is evaluated through a power generation performance analysis on building attached photovoltaic (BAPV) systems, which are representative BARESs. The average performance ratio (PR) was 68.97%, with 78.42% in 2012 when monitoring started and 62.34% after 6 years. The PR continued to decline over time, with a difference of 16.07% between 2012 and 2018. In addition, the losses were 2.22%, 3.14%, 3.51%, and 22.16% over the entire period for the balance of the system (BOS), module temperature, incident angle modifier, and miscellaneous losses, respectively. Although other losses did not change over time, the miscellaneous loss was 10.43% in 2012, which increased to 29.49% in 2018. The BAPV system has experienced a continuous performance degradation since 2012. This indicates that managers have conducted no maintenance or performance surveys. Furthermore, more power can be generated by the BAPV system if maintenance is regularly conducted. The literature review has shown that a system installed for regulation or certification is not maintained, and that the facility managers are being challenged. Therefore, it is necessary to consider means to guide the maintenance points or methods applied.

Abstract

Regulations and certification systems have been installed in many building-applied renewable energy systems (BARESs). Efforts to investigate and maintain the performance of renewable energy systems (RESs) have been lacking from the perspective of users or facility managers. This maintenance issue has obstructed the RES from operating in terms of its original purpose. Therefore, in this study, the operation status is evaluated through a power generation performance analysis on building attached photovoltaic (BAPV) systems, which are representative BARESs. The average performance ratio (PR) was 68.97%, with 78.42% in 2012 when monitoring started and 62.34% after 6 years. The PR continued to decline over time, with a difference of 16.07% between 2012 and 2018. In addition, the losses were 2.22%, 3.14%, 3.51%, and 22.16% over the entire period for the balance of the system (BOS), module temperature, incident angle modifier, and miscellaneous losses, respectively. Although other losses did not change over time, the miscellaneous loss was 10.43% in 2012, which increased to 29.49% in 2018. The BAPV system has experienced a continuous performance degradation since 2012. This indicates that managers have conducted no maintenance or performance surveys. Furthermore, more power can be generated by the BAPV system if maintenance is regularly conducted. The literature review has shown that a system installed for regulation or certification is not maintained, and that the facility managers are being challenged. Therefore, it is necessary to consider means to guide the maintenance points or methods applied.

참고문헌 (19)

  1. "The Portal of Climate Change Promotions"[URL]
  2. Kim, Y. W., "Study on the Certification Policy of Zero-Energy Buildings in Korea", Sustainability, 12, pp.5172~ (2020)
  3. "Zero Energy Building Policy Trends"[URL]
  4. "Korea Energy Agency"[URL]
  5. Zero Energy Building_Technology & Component Ver. 2, "Korea Energy Agency", Korea Energy Agency, ~ (2021)
  6. 양승만, "공공건물 신재생에너지 설치의무화 제도의 시행상 문제점 분석 및 개선안 : 대학시설을 중심으로", 석사, 건설경영학과, pp.2014
  7. Choi, J. H., "The Technologies Selection of Applicable Renewable Energies for Construction field", Proceeding of KICEM Annual Conference, pp.529~530 (2012), Korea Institute of Construction Engineering and Management
  8. 김미란, "국내와 독일의 신재생에너지 적용 건축물 사례 연구 - 태양광 및 지열에너지 적용 사례를 중심으로 -", 대한건축학회논문집, 28(03), pp.29~37 (2012), 대한건축학회
  9. Kim, H. S., "Energy Saving Technology for High Rise Buildings Using Renewable Energy - Focused on BIPV Application Technology", The magazine of Korean Solar Energy Society, 10(1), pp.11~21 (2011)
  10. 장향인, "건축물 신재생에너지원의 이용 현황 및 문제점 분석", 한국태양에너지학회 논문집, 32(5), pp.75~82 (2012), 한국태양에너지학회
  11. IEC 61724-1:2017 Photovoltaic System Performance – Part 1 :Monitoring, "International Electrotechnical Commission", International Electrotechnical Commission, ~ (2017)
  12. Lee, H. M., "Operational Power Performance of South-facing Vertical BIPV Window System Applied in Office Building", Solar Energy, 145, pp.66~77 (2017)
  13. Souka, A. F., "Determination of the Optimum Orientations for the Double-exposure, Flat-plate Collector and Its Reflectors", Solar Energy, 10(4), pp.170~174 (1966)
  14. IEA-PVPS Task 13 Report – Review of Failures of Photovoltaic Modules, "International Energy Agency", International Energy Agency, ~ (2014)
  15. Lee, K. Y., "The Impact of Cracks in BIPV Modules on Power Outputs: A Case Study Based on Measured and Simulated Data", Energies, 14, pp.836~ (2021)
  16. Tsanakas, J. A., "Claudia Buerhop, Faults and Infrared Thermo-graphic Diagnosis in Operating c-Si Photovoltaic Modules: A Review of Research and Future Challenges", Renewable and Sustainable Energy Reviews, 62, pp.695~709 (2016)
  17. Jeong, J. S., "Field Discoloration Analysis and UV", temperature Accelerated Degradation Test of EVA for PV, 2014 (2013), ~
  18. Mohammad, R. M, "Power loss due to Soiling on Solar Panel: A Review", Renewable and Sustainable Energy Reviews, 59, pp.1307~1316 (2016)
  19. Lorenzo, E., "Dust Effects on PV Array Performance: In‐field Observations with Non-uniform Patterns", Progress in Photovoltaics, 22, pp.666~670 (2014)