BIPV시스템의 건물적용 실증에 대한 구성요소별 발전성능 분석
A study on the performance of various BIPV modules applied in a real building demonstration
2
조회
0
다운로드
7
인용
0
참고문헌
키워드
초록
Building Integrated Photovoltaic (BIPV) is one of the best ways to generate electric power using the solar energy, which is clean and inexhaustible energy resources. The most of BIPV modules have the form of GtoG (Glass to Glass) photovoltaic in building applications. Degradation leading to failure in photovoltaic modules is very important factor in BIPV modules. This paper analyzed the performance of various BIPV modules through outdoor exposure tests. Performance of three BIPV modules(c-Si type, a-Si type and DSSC type) with three installation angles influenced by sun light, outdoor temperature, and wind velocity was monitored and analyzed. As a result, c-Si type BIPV module outperforms other BIPV modules(a-Si type). In terms of power efficiency of the module, the installed angle of 45° is better than others(90 degree, 0 degree). In addition, more realistic data of various BIPV system performance could be available through the field test and integrated building test. In this study, relationship of the BIPV system is identified module's installation angle, power generation, architectural performance, etc.
Abstract
Building Integrated Photovoltaic (BIPV) is one of the best ways to generate electric power using the solar energy, which is clean and inexhaustible energy resources. The most of BIPV modules have the form of GtoG (Glass to Glass) photovoltaic in building applications. Degradation leading to failure in photovoltaic modules is very important factor in BIPV modules. This paper analyzed the performance of various BIPV modules through outdoor exposure tests. Performance of three BIPV modules(c-Si type, a-Si type and DSSC type) with three installation angles influenced by sun light, outdoor temperature, and wind velocity was monitored and analyzed. As a result, c-Si type BIPV module outperforms other BIPV modules(a-Si type). In terms of power efficiency of the module, the installed angle of 45° is better than others(90 degree, 0 degree). In addition, more realistic data of various BIPV system performance could be available through the field test and integrated building test. In this study, relationship of the BIPV system is identified module's installation angle, power generation, architectural performance, etc.
참고문헌 (6)
- 윤정인, "다양한 작동유체를 이용한 20 kW급 해양온도차 발전 사이클 성능 분석", 한국마린엔지니어링학회지, 37(8), pp.836~842 (2013), 한국마린엔지니어링학회[DOI]
- Yoon. J. I, "Efficiency comparison of subcritical OTEC power cycle using various working fluids", Journal of Heat and Mass Transfer, 50(7), pp.985~996 (2014)
- 윤정인, "온배수를 이용한 혼합냉매용 해양온도차 발전 사이클의 성능 특성", 한국동력기계공학회지, 17(6), pp.103~108 (2013), 한국동력기계공학회
- T. C. Hunga, "A study of organic working fluids on system efficiency of an ORC using low-grade energy sources", Journal of the Korea Society for Power system Engineering, 35(3), pp.1403~1411 (2013)
- Athanasios I. Papadopoulos, "On the systematic design and selection of optimal working fluids for Organic Rankine Cycles", Applied Thermal Engineering, 30, pp.760~769 (2010)
- "Aspen HYSYS. Version 8.0" (2014), Aspen Technology Inc