실측을 통한 북향 설치 PV 시스템의 발전성능 평가
The Assessments of Operational Performance for North-facing PV System based on Measured Data
1
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Photovoltaic (PV) systems are commonly used as on-site electric power generators for ZEBs in the Republic of Korea. To enhance the performance of PV systems, considering efficient installation conditions, such as the optimal azimuth and tilt angles, is critical. Under domestic PV application guidelines, the azimuth of installation for building-applied PV systems is stipulated within a maximum of ±90° based on the south-facing direction. In general, the north- facing direction is known as a weak position for PV systems. However, several studies have shown that the north-facing direction can be a good option for building PV installations, typically when the installation areas are limited within a building site. Even if the PV panel faces north, the system can operate effectively with proper performance when installed at a suitable inclination angle. In existing studies, system behavior has been verified based on simulation- based analysis, but actual operational data analysis remains insufficient. This study aims to evaluate the feasibility of north-facing PV systems based on a performance evaluation of the measured data of a roof PV system. The roof PV system analyzed in this study was composed of modules, module-level power electronics (MLPE), and one inverter. The PV modules and MLPEs were installed on both the southern (SIR) and northern (NIR) inclined roofs. Based on the annual cumulative DC power, the energy yields of the MLPE connected to modules of the SIR and NIR are 1,445.0 and 1,068.7 kWh/kWp, respectively. Our study found that the ratio of the performance of MLPE on the NIR to MLPE on the SIR was 74.0%. This ratio was similar to the energy yield of the PV system on the south vertical plane as compared to that on the south slope plane. The analyzed results revealed that an acceptable performance of the PV system installed on a northern slope at a suitable inclination angle could be expected as compared with other PV installations such as the southern vertical.
Abstract
Photovoltaic (PV) systems are commonly used as on-site electric power generators for ZEBs in the Republic of Korea. To enhance the performance of PV systems, considering efficient installation conditions, such as the optimal azimuth and tilt angles, is critical. Under domestic PV application guidelines, the azimuth of installation for building-applied PV systems is stipulated within a maximum of ±90° based on the south-facing direction. In general, the north- facing direction is known as a weak position for PV systems. However, several studies have shown that the north-facing direction can be a good option for building PV installations, typically when the installation areas are limited within a building site. Even if the PV panel faces north, the system can operate effectively with proper performance when installed at a suitable inclination angle. In existing studies, system behavior has been verified based on simulation- based analysis, but actual operational data analysis remains insufficient. This study aims to evaluate the feasibility of north-facing PV systems based on a performance evaluation of the measured data of a roof PV system. The roof PV system analyzed in this study was composed of modules, module-level power electronics (MLPE), and one inverter. The PV modules and MLPEs were installed on both the southern (SIR) and northern (NIR) inclined roofs. Based on the annual cumulative DC power, the energy yields of the MLPE connected to modules of the SIR and NIR are 1,445.0 and 1,068.7 kWh/kWp, respectively. Our study found that the ratio of the performance of MLPE on the NIR to MLPE on the SIR was 74.0%. This ratio was similar to the energy yield of the PV system on the south vertical plane as compared to that on the south slope plane. The analyzed results revealed that an acceptable performance of the PV system installed on a northern slope at a suitable inclination angle could be expected as compared with other PV installations such as the southern vertical.
참고문헌 (14)
- "Zero Energy Building Policy Trends" (2022)[URL]
- "Best Practices for Consulting Support Projects for Zero Energy Buildings" (2022)[URL]
- "Guidelines for Support of New and Renewable Energy Facilities" (2022)[URL]
- 박재완, "건물일체형 태양광발전 시스템의 발전성능 분석", 한국태양에너지학회 논문집, 33(3), pp.75~81 (2013), 한국태양에너지학회
- 조가영, "건물일체형 태양광발전(BIPV) 시스템 실증분석 및 열성능 평가", 한국태양에너지학회 논문집, 41(1), pp.69~77 (2021), 한국태양에너지학회[DOI]
- 이상문, "BIPV시스템의 건물적용 실증에 대한 구성요소별 발전성능 분석", 한국태양에너지학회 논문집, 36(2), pp.53~63 (2016), 한국태양에너지학회
- 박경은, "12kW급 건물일체형 태양광발전시스템 사례분석", 한국태양에너지학회 논문집, 29(1), pp.18~23 (2009), 한국태양에너지학회
- Hyo Mun Lee, "Operational power performance of south-facing vertical BIPV window system applied in office building", Solar Energy, 145, pp.66~77 (2017), Elsevier BV[DOI]
- Chul-sung Lee, "Performance Evaluation and Prediction of BIPV Systems under Partial Shading Conditions Using Normalized Efficiency", Energies, 12(19), pp.3777~ (2019), MDPI AG[DOI]
- 김덕성, "주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가", 한국태양에너지학회 논문집, 37(2), pp.35~45 (2017), 한국태양에너지학회[DOI]
- 오명석, "아파트에 적용된 태양광발전 시스템의 성능평가 및 개선방안에 관한 연구", 대한건축학회논문집, 24(10), pp.243~250 (2008), 대한건축학회
- Hyomun Lee, "Energy performance evaluation of a plus energy house based on operational data for two years: A case study of an all-electric plus energy house in Korea", Energy and Buildings, 252, pp.111394~ (2021), Elsevier BV[DOI]
- 김동수, "건물적용 태양광발전시스템의 국내 지역에 따른 설치각도별 연간 전력생산량 예측에 관한 연구", KIEAE Journal, 14(1), pp.67~74 (2014), 한국생태환경건축학회[DOI]
- Choi, M. J., "The Review of Evaluation Tool (ECO2) for Certification of Building Energy Performance in Republic of Korea", 2022 Summer Annual Conference of The Society of Air-conditioning and Refrigerating Engineering of Korea, pp.882~885 (2022)
