The government is encouraging new & renewable energy systems such as installation support in house and building, PV rental, and so on. Especially, PV(Photovoltaic) system has the highest percentage of the renewable energy system in Korea and the share of PV is increasing every year. There is a problem with a shortage of PV sites, but the building PV system has attracted attention as an alternative. The PV system consists of a module(array), a connection-box, an inverter, a weather observation box, and a monitoring system. The monitoring software support managing and operating of PV system. In order to operate efficiently a PV system, it is necessary to analyze power performance as well as data monitoring. In this paper, the performance of building PV system(20kW and 30kW) is analyzed by reviewing the relations between PV Power, yield and module temperature. As a result of this study, PV system performance was related to power loss in array and inverter. The efficiency of the array was decreased due to the fluctuation of solar radiation and the high module temperature. Especially, module temperature was influenced by outside temperature, solar radiation, wind speed. The power loss in the inverter was caused by inverter efficiency.
Abstract
The government is encouraging new & renewable energy systems such as installation support in house and building, PV rental, and so on. Especially, PV(Photovoltaic) system has the highest percentage of the renewable energy system in Korea and the share of PV is increasing every year. There is a problem with a shortage of PV sites, but the building PV system has attracted attention as an alternative. The PV system consists of a module(array), a connection-box, an inverter, a weather observation box, and a monitoring system. The monitoring software support managing and operating of PV system. In order to operate efficiently a PV system, it is necessary to analyze power performance as well as data monitoring. In this paper, the performance of building PV system(20kW and 30kW) is analyzed by reviewing the relations between PV Power, yield and module temperature. As a result of this study, PV system performance was related to power loss in array and inverter. The efficiency of the array was decreased due to the fluctuation of solar radiation and the high module temperature. Especially, module temperature was influenced by outside temperature, solar radiation, wind speed. The power loss in the inverter was caused by inverter efficiency.
참고문헌 (9)
- Yuzuru Ued, "Performance analysis of various system configurations on grid-connected residential PV systems", Solar Energy Materials & Solar Cells, 93, pp.945~949 (2009)
- 박재완, "건물일체형 태양광발전 시스템의 발전성능 분석", 한국태양에너지학회 논문집, 33(3), pp.75~81 (2013), 한국태양에너지학회
- 소정훈, "계통연계형 태양광발전 시스템의 고장유형별 손실 비교분석", 한국태양에너지학회 논문집, 37(3), pp.23~32 (2017), 한국태양에너지학회[DOI]
- 차왕철, "온도와 풍속에 따른 태양광발전 효율 실증분석 연구", 전기학회 논문지 P권, 64(1), pp.1~6 (2015), 대한전기학회
- 한국에너지공단 신·재생에너지센터, "공공기관 신·증·개축 건축물 신·재생에너지 설치의무화제도 안내", ~ (2018)
- 엄지영, "20kW급 건물 태양광발전시스템의 기상요소에 따른 성능분석 및 BEMS 연계 방안", 대한설비공학회 하계학술발표대회 논문집, pp.845~848 (2017)
- Jiyoung Eum, "Performance analysis of photovoltaic systems by meteorological factors in Korea", International Conference on Renewable Energy and Environment(ICREE), pp.30~ (2017)
- 엄지영, "건물용 태양광발전 모니터링 시스템의주요 기능 분석 및 BEMS와의 통합방안", 대한설비공학회 설비저널, 47(11), pp.42~50 (2018)
- G. Notton, "Optimal sizing of a grid-connected PV system for various PV module technologies and inclinations, inverter efficiency characteristics and locations", Renewable Energy, 35, pp.541~554 (2010)