주거용 건물 태양광발전시스템의 설치유형에 따른 발전성능 평가
Evaluation of Electricity Generation According to Installation Type of Photovoltaic System in Residential Buildings
2
조회
0
다운로드
6
인용
0
참고문헌
키워드
초록
The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was –6.5 to 61.0°C for mounted modules, –6.0~73.9°C for semi-integrated modules and –5.5 to 88.9°C for integrated modules. The temperature loss of each installation type was –14.0 to 16.1%, –13.8 to 21.9%, and –13.6 to 28.5%, respectively.
Abstract
The types of installation of the photovoltaic system applied to domestic residential buildings are classified as follows: Mounted modules with air circulation, semi-integrated modules with air duct behind, integrated modules with fully insulated back. In order to study generation characteristics of PV system, we verified the validity of interpretation program based on long-term measurement data of demonstration house installed in BAPV form and also analyzed the generation characteristics and performance of each installation type. The results are as follows. First, the RMSE of amount of generation and simulation according to annual daily insolation of demonstration system located in Daejeon was 0.98kWh and the range of relative error of monthly power generation was -5.8 to 3.1. Second, the average annual PR of mounted modules was 82%, semi-integrated modules 76.1% and integrated modules 71.9%. This differences were attributed to temperature loss. Third, the range of operating temperature of annual hourly photovoltaic modules was –6.5 to 61.0°C for mounted modules, –6.0~73.9°C for semi-integrated modules and –5.5 to 88.9°C for integrated modules. The temperature loss of each installation type was –14.0 to 16.1%, –13.8 to 21.9%, and –13.6 to 28.5%, respectively.
참고문헌 (8)
- Verbernel, G., "BIPV PRODUCTS FOR FACADES AND ROOFS: A MARKET ANALYSIS", 29th EU-PVSEC in Amsterdam (2014)
- 윤종호, "건물일체형 태양광 발전 (BIPV) 기술 동향", 전기전자재료학회논문지, 27(1), pp.1~7 (2014), 한국전기전자재료학회[DOI]
- 윤종호, "후면 환기조건에 따른 건물외피용 태양광발전(BIPV) 모듈의 열적 영향에 관한 실험연구", 한국태양에너지학회 논문집, 26(1), pp.81~90 (2006), 한국태양에너지학회
- 김경수, "지붕 설치형 결정질 실리콘 태양전지모듈의 온도 특성", 한국태양에너지학회 논문집, 32(3), pp.11~18 (2012), 한국태양에너지학회
- 오병칠, "The Economic Feasibility of Building-Integrated Photovoltaics System Installed on the Roof of Residential Building - Focused on Comparison with Construction Cost of BAPV System Depend on Roof Finishing Materials", KIEAE Journal, 71(1), pp.15~21 (2017), 한국생태환경건축학회
- PVsyst, "User’s Guide, PVsyst Contextual Help", PVsyst SA 1994-2012, ~