국부상의치의 전해연마에 따른 SLS 3D 프린터의 적합성 평가
Assessment of the fit of partial frame fabricated by SLS 3D printer
0
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
Objectives: The present study aimed to compare the accuracy of removable partial denture (RPD) frameworks fabricated by selective laser sintering (SLS) before and after electropolishing. Methods: A partially edentulous mandibular model was used as the working model. Scanning of the model was performed using a dental scanner. The framework was designed using CAD software. The metal framework was formed using an SLS 3D printer. 3D scans of the two fabricated prototypes produced before and after electropolishing were overlapped with reference data. The fit was calculated based on Root Mean Square (RMS). Fabrication accuracy was verified using the paired t-test to compare the discrepancy before and after electropolishing. Results: The mean (SD) values of RMS before and after electropolishing were 126.6 (34.19) and 75.86 (21.36), respectively. There was a statistically significant difference before and after electropolishing (p<0.05). Conclusions: Metal frameworks made with SLS 3D printers showed clinically acceptable fit after electropolishing.
Abstract
Objectives: The present study aimed to compare the accuracy of removable partial denture (RPD) frameworks fabricated by selective laser sintering (SLS) before and after electropolishing. Methods: A partially edentulous mandibular model was used as the working model. Scanning of the model was performed using a dental scanner. The framework was designed using CAD software. The metal framework was formed using an SLS 3D printer. 3D scans of the two fabricated prototypes produced before and after electropolishing were overlapped with reference data. The fit was calculated based on Root Mean Square (RMS). Fabrication accuracy was verified using the paired t-test to compare the discrepancy before and after electropolishing. Results: The mean (SD) values of RMS before and after electropolishing were 126.6 (34.19) and 75.86 (21.36), respectively. There was a statistically significant difference before and after electropolishing (p<0.05). Conclusions: Metal frameworks made with SLS 3D printers showed clinically acceptable fit after electropolishing.
참고문헌 (24)
- Kang HW, "Removable partial denture prosthodontics", pp.4~ (2012), Jisung Publishing House
- Lee HS, "Complete denture technology", pp.1~ (2016), Komoonsa
- Hong MH, "The study on inner stability of the dental SLM alloy body by conditions of the electro-polishing", Master, pp.2013
- 장재영, "치과 주조용 Co.Cr-Mo alloy에서 전해용액 온도와 전해시간에 따른 전해연마의 특성", 대한치과기공학회지, 34(2), pp.145~153 (2012), 대한치과기공학회[DOI]
- Akinori Tasaka, "Accuracy of removable partial denture framework fabricated by casting with a 3D printed pattern and selective laser sintering", Journal of Prosthodontic Research (2019), Elsevier BV[DOI]
- 지해성, "레이저를 이용한 직접금속조형(DMD) 기술", 한국CDE학회 논문집, 8(3), pp.150~156 (2003), 한국CDE학회
- 김현아, "적층가공을 이용한 임시의치 제작 및 기존방식의 임시의치와의 비교 증례", 대한치과보철학회지, 57(4), pp.483~489 (2019), 대한치과보철학회[DOI]
- 송준기, "절삭 및 적층 가공 방법으로 제작된 작업 모형의 정확도 비교", 대한치과재료학회지, 45(1), pp.89~96 (2018), 대한치과재료학회[DOI]
- Kim JD, "Solid freeform fabrication of metal prototype using direct metal shaping process", Jonrnal of KSPE, 17(10), pp.56~62 (2000)
- Murakami I, "Aspects of metal-ceramic bonding", Dent Clin North Am, 31, pp.333~346 (1987)
- Lee ES, "Removal of micro burr by using Electrolytic-deburring", Jonrnal of KSPE, 22(9), pp.20~26 (2005)
- 박선아, "Computer-aided design (CAD) 및 쾌속조형술을 이용한 가철성 국소의치 수복 증례", 대한치과보철학회지, 55(1), pp.94~99 (2017), 대한치과보철학회[DOI]
- 이지수, "디지털 방식을 이용하여 제작한 양악 가철성 의치 수복 증례", 대한치과보철학회지, 56(3), pp.250~257 (2018), 대한치과보철학회[DOI]
- Omar Alageel, "Removable partial denture alloys processed by laser‐sintering technique", Journal of Biomedical Materials Research Part B: Applied Biomaterials, 106(3), pp.1174~1185 (2018), Wiley[DOI]
- Khalid Arafa, "Assessment of the fit of removable partial denture fabricated by computer-aided designing", computer aided manufacturing technology, 2018, pp.39(1), 17~22[DOI]
- Julia Magalhaes Costa Lima, "Removable Partial Dentures: Use of Rapid Prototyping", Journal of Prosthodontics, 23(7), pp.588~591 (2014), Wiley[DOI]
- Omar Alageel, "Removable partial denture alloys processed by laser‐sintering technique", Journal of Biomedical Materials Research Part B: Applied Biomaterials, 106(3), pp.1174~1185 (2018), Wiley[DOI]
- Balqees Almufleh, "Patient satisfaction with laser-sintered removable partial dentures: A crossover pilot clinical trial", The Journal of Prosthetic Dentistry, 119(4), pp.560~567.e1 (2018), Elsevier BV[DOI]
- Andreas Ender, "In vivo precision of conventional and digital methods of obtaining complete-arch dental impressions", The Journal of Prosthetic Dentistry, 115(3), pp.313~320 (2016), Elsevier BV[DOI]
- Panos Papaspyridakos, "Digital versus conventional implant impressions for edentulous patients: accuracy outcomes", Clinical Oral Implants Research, 27(4), pp.465~472 (2016), Wiley[DOI]
- Liu YF, "A preliminary study on the forming quality of titanium alloy removable partial denture frameworks fabricated by selective laser melting", Zhonghua Kou Qiang Yi Xue Za Zhi, 52(6), pp.351~354 (2017)
- D.A. Felton, "Effect of in vivo crown margin discrepancies on periodontal health", The Journal of Prosthetic Dentistry, 65(3), pp.357~364 (1991), Elsevier BV[DOI]
- Abdollah Malekjafarian, "Investigation of Buckling Capacity of Metal Materials Manufactured by Laser 3D Printing", Procedia Manufacturing, 7, pp.696~700 (2017), Elsevier BV[DOI]
- C. Li, "Fast Prediction and Validation of Part Distortion in Selective Laser Melting", Procedia Manufacturing, 1, pp.355~365 (2015), Elsevier BV[DOI]