A study of multi-parameter impact on beam position accuracy for scanning proton therapy

5

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

Pencil beam scanning (PBS) has become the dominant beam delivery method in proton therapy facilities, owing to its high dose conformality and high beam utilization. While prescribed dose distribution necessitates accurate control of both irradiation position and dose, critical factors including magnetic field fluctuation, mechanical deformation, and beam orbit distortion may impact irradiation position accuracy. This study quantitatively evaluates the impacts of these three factors on irradiation position accuracy for the SC200 proton therapy system. Firstly, three-dimensional magnetic field data of nozzle were acquired through COMSOL simulation and subsequently validated against experimental measurements. Secondly, the simulated field data were utilized to Monte Carlo assessment of individual parameter effects: (1) power supply ripple and (2) beam orbit distortion on irradiation position accuracy, along with (3) analysis of gantry deformation-induced isocenter shifts. Thirdly, the combined effects of these three critical parameters on irradiation accuracy were systematically analyzed. Results reveal that irradiation position deviation patterns under multi-parameter interactions exhibit complex behavior, with beam orbit fluctuations showing the most significant impact in three-dimensional magnetic field, particularly through quadrant-dependent deviation inconsistencies. The study further proposes orienting beam orbit distortion toward the fourth quadrant, demonstrating that this approach can largely maintain irradiation position deviations within ±0.5 mm in both X and Y directions under combined parameter effects. These findings establish a foundation for future high-precision dose delivery system design.

Abstract

Pencil beam scanning (PBS) has become the dominant beam delivery method in proton therapy facilities, owing to its high dose conformality and high beam utilization. While prescribed dose distribution necessitates accurate control of both irradiation position and dose, critical factors including magnetic field fluctuation, mechanical deformation, and beam orbit distortion may impact irradiation position accuracy. This study quantitatively evaluates the impacts of these three factors on irradiation position accuracy for the SC200 proton therapy system. Firstly, three-dimensional magnetic field data of nozzle were acquired through COMSOL simulation and subsequently validated against experimental measurements. Secondly, the simulated field data were utilized to Monte Carlo assessment of individual parameter effects: (1) power supply ripple and (2) beam orbit distortion on irradiation position accuracy, along with (3) analysis of gantry deformation-induced isocenter shifts. Thirdly, the combined effects of these three critical parameters on irradiation accuracy were systematically analyzed. Results reveal that irradiation position deviation patterns under multi-parameter interactions exhibit complex behavior, with beam orbit fluctuations showing the most significant impact in three-dimensional magnetic field, particularly through quadrant-dependent deviation inconsistencies. The study further proposes orienting beam orbit distortion toward the fourth quadrant, demonstrating that this approach can largely maintain irradiation position deviations within ±0.5 mm in both X and Y directions under combined parameter effects. These findings establish a foundation for future high-precision dose delivery system design.

관련 논문AI추천

Start-to-end modeling and transmission efficiency optimization for a cyclotron-based proton therapy beamlineChen Yu, Liao Yicheng, Liu Xu, Qin Bin, Wang Wei한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제10호Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy구영모, 김성훈, 김찬형, 정재린, 정종휘한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제6호Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system구영모, 김성훈, 김찬형, 장세현, 정종휘, 조성구, 조재호, 최세훈한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제9호Investigating the effects of a range shifter on skin dose in proton therapyDai Wei, Dong Lang, Li Guodong, Wang Ming, Zhang Lei, Zheng Jinxing한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제1호Upgrade of gamma electron vertex imaging system for high-performance range verifi cation in pencil beam scanning proton therapy구영모, 김성훈, 김찬형, 정재린, 정종휘, 조광현, 조성구한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제3호Beamline analysis for a laser-driven proton therapy accelerator using superconducting bendsCai Shixian, Easton Matthew, Huang Wei, Jiang Xiaopeng, Liang Yu, Li Jie, Lin Chen, Wang Kai, Wang Kedong, Wu Wei, Yan Xueqing, Zhang Caijie, Zhu Kun, Zhu Tingru한국원자력학회 · Nuclear Engineering and Technology2025 · 제57권 제3호