본문 바로가기
KERD
논문KCI 등재

Investigating the effects of a range shifter on skin dose in proton therapy

0

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류원자력공학

초록

Proton treatment may deliver a larger dose to a patient’s skin than traditional photon therapy, especially when a range shifter (RS) is inserted in the beam path. This study investigated the effects of an RS on skin dose while considering RS with different thicknesses, airgaps and materials. First, the physical model of the scanning nozzle with RS was established in the TOol for PArticle Simulation (TOPAS) code, and the effects of the RS on the skin dose were studied. Second, the variations in the skin dose and isocenter beam size were examined by reducing the air gap. Finally, the effects of different RS materials, such as polymethylmethacrylate (PMMA), Lexan, polyethylene and polystyrene, on the skin dose were analysed. The results demonstrated that the current RS design had a negligible effect on the skin dose, whereas the RS significantly impacted the isocenter beam size. The skin dose was increased considerably when the RS was placed close to the phantom. Moreover, the magnitude of the increase was related to the thickness of the inserted RS. Meanwhile, the results also revealed that the secondary proton primarily contributed to the increased skin dose.

Abstract

Proton treatment may deliver a larger dose to a patient’s skin than traditional photon therapy, especially when a range shifter (RS) is inserted in the beam path. This study investigated the effects of an RS on skin dose while considering RS with different thicknesses, airgaps and materials. First, the physical model of the scanning nozzle with RS was established in the TOol for PArticle Simulation (TOPAS) code, and the effects of the RS on the skin dose were studied. Second, the variations in the skin dose and isocenter beam size were examined by reducing the air gap. Finally, the effects of different RS materials, such as polymethylmethacrylate (PMMA), Lexan, polyethylene and polystyrene, on the skin dose were analysed. The results demonstrated that the current RS design had a negligible effect on the skin dose, whereas the RS significantly impacted the isocenter beam size. The skin dose was increased considerably when the RS was placed close to the phantom. Moreover, the magnitude of the increase was related to the thickness of the inserted RS. Meanwhile, the results also revealed that the secondary proton primarily contributed to the increased skin dose.

참고문헌 (21)

  1. H. Paganetti, "New technologies in radiation oncology", pp.345~363 (2006), Springer
  2. Y. Lee, "Skin thickness of Korean adults", Surgical and radiologic anatomy, 24(3), pp.183~189 (2002)
  3. Determination of dose equivalents resulting from external radiation sources, "International Commission on Radiation Units and Measurements", ICRU, ~, pp.Report No. 39 (1985)
  4. J. J. Cuaron, "Dosimetric comparison of skin surface dose in patients undergoing proton and photon radiation therapy for breast cancer", International Journal of Radiation Oncology, Biology, Physics, 90(1), pp.S914~ (2014)
  5. C. A. Carlsson, "Proton dosimetry with 185 MeV protons", Health physics, 33(5), pp.481~484 (1977)
  6. A. Kern, "Determination of surface dose in pencil beam scanning proton therapy", Medical Physics, 47(5), pp.2277~2288 (2020)
  7. T. Pfuhl, "Dose build-up effects induced by delta electrons and target fragments in proton Bragg curvesdmeasurements and simulations", Physics in Medicine & Biology, 63(17), pp.175002~ (2018)
  8. "Medical physics", 2015, 1335~1340
  9. R. PIDIKITI, "Commissioning of the world's First compact pencil-beam scanning proton therapy system", Journal of applied clinical medical physics, 19(1), pp.94~105 (2018)
  10. Y.G.H. YU, "Study on the influence of the range shifter material in a scanning nozzle for proton therapy based on Monte Carlo method", 10th Int. Partile Accelerator Conf.(IPAC'19), pp.4100~4102 (2019)
  11. L. Kelleter, "Simulation of dose buildup in proton pencil beams", Medical Physics, 46(8), pp.3734~3738 (2019)
  12. A. Kern, "Impact of air gap, range shifter, and delivery technique on skin dose in proton therapy", Medical Physics, 48(2), pp.831~840 (2021)
  13. J. Perl, "TOPAS: an innovative proton Monte Carlo platform for research and clinical applications", Medical physics, 39(11), pp.6818~6837 (2012)
  14. M. Wang, "Monte Carlo simulation using TOPAS for gas chamber design of PBS nozzle in superconducting proton therapy facility", Nuclear Technology, 206(5), pp.779~790 (2020)
  15. A. D. Wrixon, "New recommendations from the international commission on radiological protectionda review", Physics in Medicine & Biology, 53(8), pp.R41~ (2008)
  16. M. J. Butson, "Skin dose from radiotherapy X-ray beams : the influence of energy", Australasian radiology, 41(2), pp.148~150 (1997)
  17. B. Nilsson, "Surface dose measurements in clinical photon beams", Acta Oncologica, 28(4), pp.537~542 (1989)
  18. P. Rapley, "Surface dose measurement using TLD powder extrapolation", Medical Dosimetry, 31(3), pp.209~215 (2006)
  19. N. Dogan, "Surface and build-up region dosimetry for obliquely incident intensity modulated radiotherapy 6 MV x rays", Medical Physics, 30(12), pp.3091~3096 (2003)
  20. S. F. Kry, "Skin dose during radiotherapy : a summary and general estimation technique", Journal of applied clinical medical physics, 13(3), pp.20~34 (2012)
  21. C. Z. Jarlskog, "Physics settings for using the Geant4 toolkit in proton therapy", IEEE Transactions on nuclear science, 55(3), pp.1018~1025 (2008)

관련 논문AI추천

Performance prediction of gamma electron vertex imaging (GEVI) system for interfractional range shift detection in spot scanning proton therapy구영모, 김성훈, 김찬형, 정재린, 정종휘한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제6호Tackling range uncertainty in proton therapy: Development and evaluation of a new multi-slit prompt-gamma camera (MSPGC) system구영모, 김성훈, 김찬형, 장세현, 정종휘, 조성구, 조재호, 최세훈한국원자력학회 · Nuclear Engineering and Technology2023 · 제55권 제9호A study of multi-parameter impact on beam position accuracy for scanning proton therapyLiao Sheng, Shen Junsong, Wang Ming, Xie Guoyu, Zeng Xianhu한국원자력학회 · Nuclear Engineering and Technology2026 · 제58권 제2호Upgrade of gamma electron vertex imaging system for high-performance range verifi cation in pencil beam scanning proton therapy구영모, 김성훈, 김찬형, 정재린, 정종휘, 조광현, 조성구한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제3호New algorithm to estimate proton beam range for multi-slit prompt-gamma camera구영모, 김찬형, 정재린한국원자력학회 · Nuclear Engineering and Technology2022 · 제54권 제9호Secondary fragments of proton and helium ion beams in High-Density Polyethylene phantom: A Monte Carlo simulation studyEfendi M. Arif, Ying Chee Keat한국원자력학회 · Nuclear Engineering and Technology2024 · 제56권 제5호

이 간행물의 다른 논문 (39건)