광 도파관이 외부로 노출된 구조를 가지는 비분산적외선 이산화탄소 센서
Non-dispersive infrared carbon dioxide sensor with an externally exposed optical cavity
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
In this study, a Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO2) sensor with an externally exposed optical cavity is proposed for improving sensitivity. NDIR CO2 sensors with high performance must use a lamp-type infrared (IR) source with a strong IR intensity. However, a lamp-type IR source generates high thermal energy that induces thermal noise, interfering with the accuracy of the CO2 concentration measure. To solve this problem, the optical cavity of the NDIR CO2 sensor is exposed to quickly dissipate heat. As a result, the proposed NDIR CO2 sensor has a shorter warm-up time and a higher sensitivity compared to the conventional NDIR CO2 sensor.
Abstract
In this study, a Non-Dispersive Infrared (NDIR) Carbon Dioxide (CO2) sensor with an externally exposed optical cavity is proposed for improving sensitivity. NDIR CO2 sensors with high performance must use a lamp-type infrared (IR) source with a strong IR intensity. However, a lamp-type IR source generates high thermal energy that induces thermal noise, interfering with the accuracy of the CO2 concentration measure. To solve this problem, the optical cavity of the NDIR CO2 sensor is exposed to quickly dissipate heat. As a result, the proposed NDIR CO2 sensor has a shorter warm-up time and a higher sensitivity compared to the conventional NDIR CO2 sensor.
참고문헌 (9)
- J. Wang, "Mid-infrared absorption-spectroscopy-based carbon dioxide sensor network in greenhouse agriculture : Development and deployment", Appl. Opt., 55(25), pp.7029~7036 (2016)
- A. Ortiz Perez, "A wireless gas sensor network to monitor indoor environmental quality in schools", Sensors, 18(12), pp.4345(1)~4345(13) (2018)
- S.L. Wells, "CO2 technology platform : An important tool for environmental problem solving", Angew. Chem. Int. Ed, 40(3), pp.518~527 (2001)
- T. V. Dinh, "A review on non-dispersive infrared gas sensors : Improvement of sensor detection limit and interference correction", Sensors Actuators, B Chem., 231, pp.529~538 (2016)
- L. Fleming, "Reducing N2O induced cross-talk in a NDIR CO2 gas sensor for breath analysis using multilayer thin film optical interference coatings", Surf. Coatings Technol., 336, pp.9~16 (2018)
- R. Frodl, "A High-Precision NDIR CO2 gas sensor for automotive applications", IEEE Sens. J., 6(6), pp.1697~1705 (2006)
- J. Hodgkinson, "A low cost, optically efficient carbon dioxide sensor based on non-dispersive infra-red (NDIR) measurement at 4.2μm", Opt. Sens. Detect. II., 8439, pp.843919~ (2012)
- X. Jia, "A miniaturized, fully integrated NDIR CO2 sensor on-chip", Sensors, 21(16), pp.5347(1)~5347(14) (2012)
- L. Kocsis, "The modified Beer-Lambert law revisited", Phys. Med. Biol, 51(5), pp.N91(1)~N91(8) (2006)
