초록

NDIR CO2 gas sensor was prototyped with ASIC implemented thermopile sensor which included temperature sensor and White-Cell structure in this paper. The temperature dependency of dual infrared sensors (CO2 and reference IR sensors) has been characterized and their output voltage ratios according to the temperature and gas concentration were presented in this paper for achieving temperature compensation algorithm. The initial output voltages of NDIR CO2 gas and reference IR sensors showed 3rd order polynomial and linear output voltages according to the variation of ambient temperatures from 253 K to 333 K, respectively. The output voltages of temperature sensor presented a linear dependency according to the ambient temperature and could be described with . The characteristics of output voltage ratios could be modeled with five parameters which are dependent upon the ambient temperatures and gas concentration. The estimated CO2 concentrations showed relatively high error below 300 ppm (maximum 572 % at 7 ppm CO2 concentration), however, as the concentration increased from 500 ppm to 2,000 ppm, the overall estimated errors of CO2 concentrations were less than ±10% in this research

Abstract

NDIR CO2 gas sensor was prototyped with ASIC implemented thermopile sensor which included temperature sensor and White-Cell structure in this paper. The temperature dependency of dual infrared sensors (CO2 and reference IR sensors) has been characterized and their output voltage ratios according to the temperature and gas concentration were presented in this paper for achieving temperature compensation algorithm. The initial output voltages of NDIR CO2 gas and reference IR sensors showed 3rd order polynomial and linear output voltages according to the variation of ambient temperatures from 253 K to 333 K, respectively. The output voltages of temperature sensor presented a linear dependency according to the ambient temperature and could be described with . The characteristics of output voltage ratios could be modeled with five parameters which are dependent upon the ambient temperatures and gas concentration. The estimated CO2 concentrations showed relatively high error below 300 ppm (maximum 572 % at 7 ppm CO2 concentration), however, as the concentration increased from 500 ppm to 2,000 ppm, the overall estimated errors of CO2 concentrations were less than ±10% in this research

참고문헌 (12)

  1. G. Visco, "Organic carbons and TOC in waters : an overview of the international norm for its measurements", Microchemical Journal, 79, pp.185~191 (2005)
  2. K. Kaneyasu, "A carbon dioxide gas sensor based on solid electrolyte for air quality control", Sensors and Actuators B, 66, pp.56~58 (2000)
  3. N. Kawasaki, "Fast and precise method for HPLC-size exclusion chromatography with UV and TOC(NDIR)detection : Importance of multiplr detectors to evaluate the characteristics of dissolved organic matter", Water research, 45, pp.6240~6248 (2011)
  4. K. Tian, "A permeable membrane capacitance sensor for inogenic gases : Application to the measurement of total organic carbon", Analytica Chimica Acta, 652, pp.245~250 (2009)
  5. L. Lindberg, "Breath alcohol concentration determined with a new analyzer using free exhalation predicts almost precisely the arterial blood alcohol concentration", Forensic Science International, 168, pp.200~207 (2007)
  6. S. Adam, "Detection limit improvement for NDIR ethylene gas detectors using passive approaches", Sensors and Actuators B, 175, pp.246~254 (2012)
  7. John U. White, "Long optical paths of large aperture", J. Optical Soc. Am, 32, pp.285~288 (1942)
  8. 장성호, "두 개의 동일한 타원형 구조를 지닌 광 도파관의 특성", 한국가스학회지, 18(2), pp.48~54 (2014), 한국가스학회[DOI]
  9. S. H. Yi, "Characteristics of NDIR alcohol sensor with elliptical optical structures", J. Auto-Vech. Safety Assoc, 7(2), pp.39~43 (2015)
  10. J. S. Park, "Nondispersive infrared ray CH4 gas sensor using focused infrared beam structures", Sensors and Materials, 23(3), pp.147~158 (2011)
  11. 이승환, "보상용 적외선 센서를 사용한 비분산 적외선 이산화탄소 센서의 온도특성", 센서학회지, 25(2), pp.124~130 (2016), 한국센서학회[DOI]

관련 논문AI추천

이 간행물의 다른 논문 (11건)