비분산 적외선 이산화탄소 가스센서 특성의 온·습도 영향
Effects of Temperature and Humidity on NDIR CO2 Gas Sensor
2
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
This article describes the characteristics of nondispersive infrared carbon dioxide gas sensor according to the temperatures and humid- ifies. In this researches, a thermopile sensor that included application-specific integrated circuit (ASIC) was used and the White-cell structure was implemented as an optical waveguide. The developed sensor modules were installed in gas chamber and then the temperature of gas chamber has been increased from 283 K to 313 K with 10K temperature step. In order to analyze the effects of humidity levels, the relative humidity levels were changed from 30 to 80%R.H. with small humidifier. Then, the characteristics of sensor modules were acquired with the increment of carbon dioxide concentrations from 0 to 2,000 ppm. When the initial voltages of sensors were compared before and after humidifying the chamber at constant temperature, the decrements of the output voltages of sensors are like these: 9mV (reference infrared sensor), 41 mV (carbon dioxide sensor), 2 mV (temperature sensor). With the increment of ambient tem- perature, the averaged output voltage of carbon dioxide sensor was increased 19 mV, however, when the humidity level was increased, it was decreased 14mV. Based upon the experimental results, the humidity effect could be alleviated by the increment of temperature, so the effects of humidity and temperature could be only compensated by the ambient temperature itself. The estimated carbon dioxide concentrations showed 10% large errors below 200 ppm, however, the errors of the estimations of carbon dioxide concentrations were less than ±5% from 400 to 2,000 ppm.
Abstract
This article describes the characteristics of nondispersive infrared carbon dioxide gas sensor according to the temperatures and humid- ifies. In this researches, a thermopile sensor that included application-specific integrated circuit (ASIC) was used and the White-cell structure was implemented as an optical waveguide. The developed sensor modules were installed in gas chamber and then the temperature of gas chamber has been increased from 283 K to 313 K with 10K temperature step. In order to analyze the effects of humidity levels, the relative humidity levels were changed from 30 to 80%R.H. with small humidifier. Then, the characteristics of sensor modules were acquired with the increment of carbon dioxide concentrations from 0 to 2,000 ppm. When the initial voltages of sensors were compared before and after humidifying the chamber at constant temperature, the decrements of the output voltages of sensors are like these: 9mV (reference infrared sensor), 41 mV (carbon dioxide sensor), 2 mV (temperature sensor). With the increment of ambient tem- perature, the averaged output voltage of carbon dioxide sensor was increased 19 mV, however, when the humidity level was increased, it was decreased 14mV. Based upon the experimental results, the humidity effect could be alleviated by the increment of temperature, so the effects of humidity and temperature could be only compensated by the ambient temperature itself. The estimated carbon dioxide concentrations showed 10% large errors below 200 ppm, however, the errors of the estimations of carbon dioxide concentrations were less than ±5% from 400 to 2,000 ppm.
참고문헌 (13)
- 한대호, "지표수 수질관리를 위한 적정 유기물질지표 선정", 환경정책연구, 10(4), pp.61~80 (2011), 한국환경정책·평가연구원
- C. S. Kim, "Study on the total organic carbon(TOC) analytical method in freshwater", Water Qual. Division Environ. Diagn. Res. department (2005)
- N. Kawasaki, "Fast and precise method for HPLC-size exclusion chromatography with UV and TOC(NDIR) detection:Importance of multiple detectors to evaluate the characteristics of dissolved organic matter", Water Res, 45, pp.6240~6248 (2011)
- 최병철, "전기전도도법을 이용한 우레아 농도 센서 개발", 한국동력기계공학회지, 15(2), pp.55~60 (2011), 한국동력기계공학회
- John U. White, "Long optical paths of large aperture", J. Opt. Society of America, 32(5), pp.285~288 (1942)
- 이승환, "White-Cell구조를 응용한 비분산 적외선 이산화탄소 센서의 온도특성", 센서학회지, 25(5), pp.377~381 (2016), 한국센서학회
- E. Wagner, "Sens.: vol. 6: Opt. sens", pp.204~ (1991), VCH press
- R. Eisberg, "Quantumn physics of atoms, molecules, solids, nuclei, and particles", pp.1~25 (1985), John Wiley & Sons
- R. V. Maikala, "Modified Beer’s law-historical perspec-tives and relevance in near-infrared monitoring of optical properties of human tissue", Inter. J. Ind. Ergonomics, 40, pp.125~134 (2010)
- J. M. Park, "Novel NDIR CO2 sensor with two concave mirrors", Proc. Of APCOT2006, D-15 (2006)
- 전계록, "Bioelectrical Impedance Analysis at Popliteal Regions of Human Body using BIMS", 센서학회지, 25(1), pp.1~7 (2016), 한국센서학회
- 金福洙, "입자의 크기와 농도에 따른 광 산란 측정", 석사, 광학, pp.1999
- 박종선, "비분산 적외선 가스센서의 온도보상 알고리즘", 한국가스학회지, 15(4), pp.51~55 (2011), 한국가스학회