Changes in performance of small bowel capsule endoscopy based on nationwide data from a Korean Capsule Endoscopy Registry
1
조회
0
다운로드
4
인용
0
참고문헌
키워드
초록
Background/Aims: Capsule endoscopy (CE) is widely used for the diagnosis of small bowel diseases. The clinical performance and complications of small bowel CE, including completion rate, capsule retention rate, and indications, have been previously described in Korea. This study aimed at estimating the recent changes in clinical performance and complications of small bowel CE based on 17-year data from a Korean Capsule Endoscopy Registry. Methods: CE registry data from 35 hospitals were retrospectively analyzed. Clinical information, including completion rate, capsule retention rate, and indications, was collected and analyzed. In addition, the most recent 5-year data for CE examinations were compared with the previous 12-year data. Results: A total of 4,650 CE examinations were analyzed. The most common indication for CE was obscure gastrointestinal bleeding (OGIB). The overall incomplete examination rate was 16% and the capsule retention rate was 3%. Crohn’s disease was a risk factor for capsule retention. Inadequate bowel preparation was significantly associated with capsule retention and incomplete examination. An indication other than OGIB was a risk factor for incomplete examination. A recent increasing trend of CE diagnosis of Crohn’s disease was observed. The most recent 5-year incomplete examination rate for CE examinations decreased compared with that of the previous 12 years. Conclusions: The 17-year data suggested that CE is a useful and safe tool for diagnosing small bowel diseases. The incomplete examination rate of CE decreased with time, and OGIB was consistently the main indication for CE. Inadequate bowel preparation was significantly associated with capsule retention and incomplete examination.
Abstract
Background/Aims: Capsule endoscopy (CE) is widely used for the diagnosis of small bowel diseases. The clinical performance and complications of small bowel CE, including completion rate, capsule retention rate, and indications, have been previously described in Korea. This study aimed at estimating the recent changes in clinical performance and complications of small bowel CE based on 17-year data from a Korean Capsule Endoscopy Registry. Methods: CE registry data from 35 hospitals were retrospectively analyzed. Clinical information, including completion rate, capsule retention rate, and indications, was collected and analyzed. In addition, the most recent 5-year data for CE examinations were compared with the previous 12-year data. Results: A total of 4,650 CE examinations were analyzed. The most common indication for CE was obscure gastrointestinal bleeding (OGIB). The overall incomplete examination rate was 16% and the capsule retention rate was 3%. Crohn’s disease was a risk factor for capsule retention. Inadequate bowel preparation was significantly associated with capsule retention and incomplete examination. An indication other than OGIB was a risk factor for incomplete examination. A recent increasing trend of CE diagnosis of Crohn’s disease was observed. The most recent 5-year incomplete examination rate for CE examinations decreased compared with that of the previous 12 years. Conclusions: The 17-year data suggested that CE is a useful and safe tool for diagnosing small bowel diseases. The incomplete examination rate of CE decreased with time, and OGIB was consistently the main indication for CE. Inadequate bowel preparation was significantly associated with capsule retention and incomplete examination.
참고문헌 (22)
- Iddan G, "Wireless capsule endoscopy", Nature, 405, pp.417~ (2000)
- Liao Z, "Indications and detection, completion, and retention rates of small-bowel capsule endoscopy : a systematic review", Gastrointest Endosc, 71, pp.280~286 (2010)
- Rondonotti E, "Complications, limitations, and failures of capsule endoscopy : a review of 733 cases", Gastrointest Endosc, 62, pp.712~716 (2005)
- Hoog CM, "Capsule retentions and incomplete capsule endoscopy examinations : an analysis of 2300 examinations", Gastroenterol Res Pract, 2012, pp.518718~ (2012)
- Rondonotti E, "Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European Society of Gastrointestinal Endoscopy (ESGE) Technical Review", Endoscopy, 50, pp.423~446 (2018)
- Li F, "Retention of the capsule endoscope : a single-center experience of 1000capsule endoscopy procedures", Gastrointest Endosc, 68, pp.174~180 (2008)
- Mitsui K, "Retrieval of retained capsule endoscopy at small bowel stricture by double-balloon endoscopy significantly decreases surgical treatment", J Clin Gastroenterol, 50, pp.141~146 (2016)
- Makipour K, "Double balloon enteroscopy: effective and minimally invasive method for removal of retained video capsules", Dig Endosc, 26, pp.646~649 (2014)
- Van Weyenberg SJ, "Double-balloon endoscopy as the primary method for small-bowel video capsule endoscope retrieval", Gastrointest Endosc, 71, pp.535~541 (2010)
- 임윤정, "Indications for Detection, Completion, and Retention Rates of Small Bowel Capsule Endoscopy Based on the 10-Year Data from the Korean Capsule Endoscopy Registry", Clinical Endoscopy, 48(5), pp.399~404 (2015), 대한소화기내시경학회
- Enns RA, "Clinical practice guidelines for the use of video capsule endoscopy", Gastroenterology, 152, pp.497~514 (2017)
- Koulaouzidis A, "Diagnostic yield of small-bowel capsule endoscopy in patients with iron-deficiency anemia : a systematic review", Gastrointest Endosc, 76, pp.983~992 (2012)
- Raju GS, "American Gastroenterological Association(AGA)Institute technical review on obscure gastrointestinal bleeding", Gastroenterology, 133, pp.1697~1717 (2007)
- Lapalus MG, "Capsule endoscopy and bowel preparation with oral sodium phosphate : a prospective randomized controlled trial", Gastrointest Endosc, 67, pp.1091~1096 (2008)
- Rosa BJ, "Oral purgative and simethicone before small bowel capsule endoscopy", World J Gastrointest Endosc, 5, pp.67~73 (2013)
- Fisher LR, "New vision in video capsule endoscopy : current status and future directions", Nat Rev Gastroenterol Hepatol, 9, pp.392~405 (2012)
- Won Gun Kwack, "Current Status and Research into Overcoming Limitations of Capsule Endoscopy", Clinical Endoscopy, 49(1), pp.8~15 (2016), 대한소화기내시경학회
- Park SH, "A 30-year trend analysis in the epidemiology of inflammatory bowel disease in the Songpa-Kangdong District of Seoul, Korea in 1986-2015", J Crohns Colitis, 13, pp.1410~1417 (2019)
- 성재호, "Formulation and Management of Poor Bowel Preparation: A Survey Study", 대한소화기학회지, 68(2), pp.70~76 (2016), 대한소화기학회
- Seo EH, "Optimal preparation-to-colonoscopy interval in split-dose PEG bowel preparation determines satisfactory bowel preparation quality : an observational prospective study", Gastrointest Endosc, 75, pp.583~590 (2012)
- Siddiqui AA, "Duration of the interval between the completion of bowel preparation and the start of colonoscopy predicts bowel-preparation quality", Gastrointest Endosc, 69, pp.700~706 (2009)
- Adler SN, "A novel purgative protocol for capsule endoscopy of the small bowel produces better quality of visibility than 2 l of PEG : timing is of the essence", United European Gastroenterol J, 5, pp.485~490 (2017)
