Quality Indicators for Small Bowel Capsule Endoscopy
1
조회
0
다운로드
8
인용
0
참고문헌
키워드
초록
Capsule endoscopy (CE) enables evaluation of the entire mucosal surface of the small bowel (SB), which is one of the most important steps for evaluating obscure gastrointestinal bleeding. Although the diagnostic yield of SB CE depends on many clinical factors, there are no reports on quality indicators. Thus, the Korean Gut Image Study Group (KGISG) publishes an article titled, “Quality Indicators for Small Bowel Capsule Endoscopy” under approval from the Korean Society of Gastrointestinal Endoscopy (KSGE). Herein, we initially identified process quality indicators, while the structural and outcome indicators are reserved until sufficient clinical data are accumulated. We believe that outcomes of SB CE can be improved by trying to meet our proposed quality indicators.
Abstract
Capsule endoscopy (CE) enables evaluation of the entire mucosal surface of the small bowel (SB), which is one of the most important steps for evaluating obscure gastrointestinal bleeding. Although the diagnostic yield of SB CE depends on many clinical factors, there are no reports on quality indicators. Thus, the Korean Gut Image Study Group (KGISG) publishes an article titled, “Quality Indicators for Small Bowel Capsule Endoscopy” under approval from the Korean Society of Gastrointestinal Endoscopy (KSGE). Herein, we initially identified process quality indicators, while the structural and outcome indicators are reserved until sufficient clinical data are accumulated. We believe that outcomes of SB CE can be improved by trying to meet our proposed quality indicators.
참고문헌 (85)
- Iddan G, "Wireless capsule endoscopy", Nature, 405, pp.417~ (2000)
- Hyun Joo Song, "Current status and future perspectives of capsule endoscopy", Intestinal research, 14(1), pp.21~29 (2016), 대한장연구학회
- Petersen BT, "Quality assurance for endoscopists", Best Pract Res Clin Gastroenterol, 25, pp.349~360 (2011)
- MacLean CH, "Measuring quality in arthritis care: methods for developing the arthritis foundation’s quality indicator set", Arthritis Rheum, 51, pp.193~202 (2004)
- Guyatt G, "Users’ guides to the medical literature: a manual for evidence-based clinical practice", pp.599~608 (2002), American Medical Association Press
- Rex DK, "Quality indicators for colonoscopy", Am J Gastroenterol, 101, pp.873~885 (2006)
- Pennazio M, "Small-bowel capsule endoscopy and device-assisted enteroscopy for diagnosis and treatment of small-bowel disorders: European society of gastrointestinal endoscopy (ESGE) clinical guideline", Endoscopy, 47, pp.352~376 (2015)
- Saperas E, "Capsule endoscopy versus computed tomographic or standard angiography for the diagnosis of obscure gastrointestinal bleeding", Am J Gastroenterol, 102, pp.731~737 (2007)
- 심기남, "Guideline for Capsule Endoscopy: Obscure Gastrointestinal Bleeding", Clinical Endoscopy, 46(1), pp.45~53 (2013), 대한소화기내시경학회
- Redondo-Cerezo E, "Wireless capsule endoscopy: perspectives beyond gastrointestinal bleeding", World J Gastroenterol, 20, pp.15664~15673 (2014)
- 임윤정, "Non-Steroidal Anti-Inflammatory Drug-Induced Enteropathy", Clinical Endoscopy, 45(2), pp.138~144 (2012), 대한소화기내시경학회
- Triester SL, "A meta-analysis of the yield of capsule endoscopy compared to other diagnostic modalities in patients with non-stricturing small bowel Crohn’s disease", Am J Gastroenterol, 101, pp.954~964 (2006)
- 박수경, "Guidelines for Video Capsule Endoscopy: Emphasis on Crohn’s Disease", Clinical Endoscopy, 48(2), pp.128~135 (2015), 대한소화기내시경학회
- Mikang Kim, "The role of small bowel endoscopy in small bowel Crohn’s disease: when and how?", Intestinal research, 14(3), pp.211~217 (2016), 대한장연구학회
- Syngal S, "ACG clinical guideline: genetic testing and management of hereditary gastrointestinal cancer syndromes", Am J Gastroenterol, 110, pp.223~262 (2015)
- Katsinelos P, "Diagnostic yield and clinical impact of wireless capsule endoscopy in patients with chronic abdominal pain with or without diarrhea: a Greek multicenter study", Eur J Intern Med, 22, pp.e63~e66 (2011)
- Römmele C, "Clinical experience with the PillCam patency capsule prior to video capsule endoscopy: a real-world experience", Gastroenterol Res Pract, 2016, pp.9657053~ (2016)
- Mata A, "Wireless capsule endoscopy", World J Gastroenterol, 14, pp.1969~1971 (2008)
- Chen-Wang Chang, "Intestinal Stricture in Crohn’s Disease", Intestinal research, 13(1), pp.19~26 (2015), 대한장연구학회[DOI]
- Ye BD, "Clinical features and long-term prognosis of Crohn’s disease in Korea", Scand J Gastroenterol, 45, pp.1178~1185 (2010)
- Kazuo Ohtsuka, "Magnetic resonance enterography for the evaluation of the deep small intestine in Crohn’s disease", Intestinal research, 14(2), pp.120~126 (2016), 대한장연구학회
- Panes J, "Imaging techniques for assessment of inflammatory bowel disease: joint ECCO and ESGAR evidence-based consensus guidelines", J Crohns Colitis, 7, pp.556~585 (2013)
- Rozendorn N, "Prediction of patency capsule retention in known Crohn’s disease patients by using magnetic resonance imaging", Gastrointest Endosc, 83, pp.182~187 (2016)
- Rondonotti E, "Short article: negative small-bowel cross-sectional imaging does not exclude capsule retention in high-risk patients", Eur J Gastroenterol Hepatol, 28, pp.871~875 (2016)
- Nemeth A, "Use of patency capsule in patients with established Crohn’s disease", Endoscopy, 48, pp.373~379 (2016)
- Nakamura M, "Clinical usefulness of novel tag-less agile patency capsule prior to capsule endoscopy for patients with suspected small bowel stenosis", Dig Endosc, 27, pp.61~66 (2015)
- "Patient instructions for PillCam® small bowel capsule endoscopy with the sensor belt" (2013)[URL]
- "Procedures (MiroCam®)" (2007)[URL]
- Costamagna G, "A prospective trial comparing small bowel radiographs and video capsule endoscopy for suspected small bowel disease", Gastroenterology, 123, pp.999~1005 (2002)
- Lewis BS, "Capsule endoscopy in the evaluation of patients with suspected small intestinal bleeding: results of a pilot study", Gastrointest Endosc, 56, pp.349~353 (2002)
- Ladas SD, "European society of gastrointestinal endoscopy (ESGE): recommendations (2009) on clinical use of video capsule endoscopy to investigate small-bowel, esophageal and colonic diseases", Endoscopy, 42, pp.220~227 (2010)
- Rosa BJ, "Oral purgative and simethicone before small bowel capsule endoscopy", World J Gastrointest Endosc, 5, pp.67~73 (2013)
- Song HJ, "Optimal bowel preparation for video capsule endoscopy", Gastroenterol Res Pract, 2016, pp.6802810~ (2016)
- 송현주, "Guidelines for Bowel Preparation before Video Capsule Endoscopy", Clinical Endoscopy, 46(2), pp.147~154 (2013), 대한소화기내시경학회
- Kantianis A, "Comparison of two schemes of small bowel preparation for capsule endoscopy with polyethylene glycol: a prospective, randomized single-blind study", Eur J Gastroenterol Hepatol, 21, pp.1140~1144 (2009)
- Park SC, "Effect of bowel preparation with polyethylene glycol on quality of capsule endoscopy", Dig Dis Sci, 56, pp.1769~1775 (2011)
- Ge ZZ, "The role of simeticone in small-bowel preparation for capsule endoscopy", Endoscopy, 38, pp.836~840 (2006)
- Albert J, "Simethicone for small bowel preparation for capsule endoscopy: a systematic, single-blinded, controlled study", Gastrointest Endosc, 59, pp.487~491 (2004)
- Spada C, "Polyethylene glycol plus simethicone in small-bowel preparation for capsule endoscopy", Dig Liver Dis, 42, pp.365~370 (2010)
- Wei W, "Purgative bowel cleansing combined with simethicone improves capsule endoscopy imaging", Am J Gastroenterol, 103, pp.77~82 (2008)
- Katherine R. Black, "A Single-Center Randomized Controlled Trial Evaluating Timing of Preparation for Capsule Enteroscopy", Clinical Endoscopy, 48(3), pp.234~238 (2015), 대한소화기내시경학회
- Liao Z, "Indications and detection, completion, and retention rates of small-bowel capsule endoscopy: a systematic review", Gastrointest Endosc, 71, pp.280~286 (2010)
- 임윤정, "Indications for Detection, Completion, and Retention Rates of Small Bowel Capsule Endoscopy Based on the 10-Year Data from the Korean Capsule Endoscopy Registry", Clinical Endoscopy, 48(5), pp.399~404 (2015), 대한소화기내시경학회
- Westerhof J, "Risk factors for incomplete small-bowel capsule endoscopy", Gastrointest Endosc, 69, pp.74~80 (2009)
- Rondonotti E, "Complications, limitations, and failures of capsule endoscopy: a review of 733 cases", Gastrointest Endosc, 62, pp.712~716 (2005)
- Postgate A, "Are bowel purgatives and prokinetics useful for small-bowel capsule endoscopy? A prospective randomized controlled study", Gastrointest Endosc, 69, pp.1120~1128 (2009)
- Almeida N, "The effect of metoclopramide in capsule enteroscopy", Dig Dis Sci, 55, pp.153~157 (2010)
- Leung WK, "Effect of oral erythromycin on gastric and small bowel transit time of capsule endoscopy", World J Gastroenterol, 11, pp.4865~4868 (2005)
- Caddy GR, "The effect of erythromycin on video capsule endoscopy intestinal-transit time", Gastrointest Endosc, 63, pp.262~266 (2006)
- Niv E, "Effect of erythromycin on image quality and transit time of capsule endoscopy: a two-center study", World J Gastroenterol, 14, pp.2561~2565 (2008)
- Liao Z, "Reduction of capture rate in the stomach increases the complete examination rate of capsule endoscopy: a prospective randomized controlled trial", Gastrointest Endosc, 69(3 Pt 1), pp.418~425 (2009)
- Shiotani A, "Use of an external real-time image viewer coupled with prespecified actions enhanced the complete examinations for capsule endoscopy", J Gastroenterol Hepatol, 26, pp.1270~1274 (2011)
- Gao YJ, "Endoscopic capsule placement improves the completion rate of small-bowel capsule endoscopy and increases diagnostic yield", Gastrointest Endosc, 72, pp.103~108 (2010)
- Holden JP, "Endoscopic placement of the small-bowel video capsule by using a capsule endoscope delivery device", Gastrointest Endosc, 65, pp.842~847 (2007)
- Gibbs WB, "Endoscopic deployment of video capsule endoscopy:does it guarantee a complete examination of the small bowel?", Gastrointest Endosc, 76, pp.905~909 (2012)
- Moradi M, "Improving visual quality in wireless capsule endoscopy images with contrast-limited adaptive histogram equalization", 2015 2nd International Conference on Pattern Recognition and Image Analysis (2015), IEEE Xplore
- Lee Y-G, "Improvement of blood detection accuracy using image processing techniques suitable for capsule endoscopy", International Journal of Medical, Health, Biomedical, Bioengineering and Pharmaceutical Engineering, 6, pp.168~171 (2012)
- Miaou S-G, "Transmitting capsule endoscope images with wireless lan and smart antenna systems", Biomed Eng, 18, pp.246~254 (2006)
- Dubner S, "Electromagnetic interference with implantable cardiac pacemakers by video capsule", Gastrointest Endosc, 61, pp.250~254 (2005)
- Dubner S, "Electromagnetic interference from wireless video-capsule endoscopy on implantable cardioverter-defibrillators", Pacing Clin Electrophysiol, 30, pp.472~475 (2007)
- Guyomar Y, "Interference between pacemaker and video capsule endoscopy", Pacing Clin Electrophysiol, 27, pp.1329~1330 (2004)
- Van de Bruaene C, "Small bowel capsule endoscopy:where are we after almost 15 years of use?", World J Gastrointest Endosc, 7, pp.13~36 (2015)
- Nakamura M, "A critical analysis of the effect of view mode and frame rate on reading time and lesion detection during capsule endoscopy", Dig Dis Sci, 60, pp.1743~1747 (2015)
- Kyriakos N, "Evaluation of four time-saving methods of reading capsule endoscopy videos", Eur J Gastroenterol Hepatol, 24, pp.1276~1280 (2012)
- Wolff JH, "Wireless capsule endoscopy practice makes perfect? A survey of capsule endoscopy viewing practices in the United States", Gastrointest Endosc, 69, pp.AB201~ (2009)
- Zheng Y, "Detection of lesions during capsule endoscopy: physician performance is disappointing", Am J Gastroenterol, 107, pp.554~560 (2012)
- Lewis BS, "How to read wireless capsule endoscopic images: tips of the trade", Gastrointest Endosc Clin N Am, 14, pp.11~16 (2004)
- Gunther U, "Capsule endoscopy: comparison of two different reading modes", Int J Colorectal Dis, 27, pp.521~525 (2012)
- Lewis BS, "A pooled analysis to evaluate results of capsule endoscopy trials", Endoscopy, 37, pp.960~965 (2005)
- Faigel DO, "ASGE guideline: guidelines for credentialing and granting privileges for capsule endoscopy", Gastrointest Endosc, 61, pp.503~505 (2005)
- American Association for the Study of Liver Diseases, "The gastroenterology core curriculum, third edition", Gastroenterology, 132, pp.2012~2018 (2007)
- 임윤정, "대한소화기내시경학회: 캡슐내시경의 가이드라인", Clinical Endoscopy, 37(6), pp.393~402 (2008), 대한소화기내시경학회
- Rajan E, "Training in small-bowel capsule endoscopy: assessing and defining competency", Gastrointest Endosc, 78, pp.617~622 (2013)
- Korean Gut Image Study Group, "Learning Curve of Capsule Endoscopy", Clinical Endoscopy, 46(6), pp.633~636 (2013), 대한소화기내시경학회
- Sigmundsson HK, "Capsule endoscopy (CE):interobserver comparison of interpretation", Gastrointest Endosc, 57, pp.AB165~ (2003)
- Mergener K, "Interobserver variability for reading capsule endoscopy examinations", Gastrointest Endosc, 57, pp.AB85~ (2003)
- Jang BI, "Inter-observer agreement on the interpretation of capsule endoscopy findings based on capsule endoscopy structured terminology: a multicenter study by the Korean gut image study group", Scand J Gastroenterol, 45, pp.370~374 (2010)
- Gonzalez Carro P, "Intestinal perforation due to retained wireless capsule endoscope", Endoscopy, 37, pp.684~ (2005)
- Repici A, "Acute small-bowel perforation secondary to capsule endoscopy", Gastrointest Endosc, 67, pp.180~183 (2008)
- Höög CM, "Capsule retentions and incomplete capsule endoscopy examinations:an analysis of 2300 examinations", Gastroenterol Res Pract, 2012, pp.518718~ (2012)
- Cheon JH, "Can we predict spontaneous capsule passage after retention? A nationwide study to evaluate the incidence and clinical outcomes of capsule retention", Endoscopy, 39, pp.1046~1052 (2007)
- Harrington C, "The longest duration of retention of a video capsule", BMJ Case Rep, 2014 (2014)
- Wang Y, "Treatment strategy for video capsule retention by double-balloon enteroscopy", Gut, 66, pp.754~755 (2017)
- Korman LY, "Capsule endoscopy structured terminology (CEST): proposal of a standardized and structured terminology for reporting capsule endoscopy procedures", Endoscopy, 37, pp.951~959 (2005)
- Gut Image Study Group, "KSCR, Korean standard of capsule endoscopy report", 3rd Symposium of The Korean Gut Image Study Group (2007)