Fixed Prosthetic Restoration in an Edentulous Patient with NobelGuide™ System
1
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
This report described a technique utilizing a computer-aided design (CAD) /computer-aided machining (CAM) - guided surgical implant placement and prefabricated fixed complete denture for an immediately loaded restoration. A patient with an edentulous maxilla and mandible received 6 implants in maxilla and 6 implants in the mandible using CAD/CAM surgical templates. Prefabricated provisional maxillary and mandibular implant supported fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics, function during 6 months. Definitive prostheses were fabricated.
Abstract
This report described a technique utilizing a computer-aided design (CAD) /computer-aided machining (CAM) - guided surgical implant placement and prefabricated fixed complete denture for an immediately loaded restoration. A patient with an edentulous maxilla and mandible received 6 implants in maxilla and 6 implants in the mandible using CAD/CAM surgical templates. Prefabricated provisional maxillary and mandibular implant supported fixed prostheses were connected immediately after implant installation. Provisional prostheses were evaluated for aesthetics, function during 6 months. Definitive prostheses were fabricated.
참고문헌 (27)
- Brånemark PI, "Osseointegration and its experimental background", J Prosthet Dent, 50, pp.399~410 (1983)
- Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
- Gapski R, "Critical review of immediate implant loading", Clin Oral Implants Res, 14, pp.515~527 (2003)
- Östman PO, "Immediate", early loading of dental implants. Clinical documentation and presentation of a treatment concept, 2008, pp.14, 90~112
- Degidi M, "Immediate functional loading of edentulous maxilla; a 5-year restrospective study of 388 titanium implants", J Periodontol, 76, pp.1016~1024 (2005)
- Horiuchi K, "Immediate loading of Brånemark system implants following placement in edentulous patients: a clinical report", Int J Oral Maxillofac Implants, 15, pp.824~830 (2000)
- Bergkvist G, "Immediately loaded implants supporting fixed prostheses in the edentulous maxilla: a preliminary clinical and radiologic report", Int J Oral Maxillofac Implants, 20, pp.399~405 (2005)
- Aalam AA, "Functional restoration of implants on the day of surgical placement in the fully edentulous mandible: a case series", Clin Implant Dent Relat Res, 7, pp.10~16 (2005)
- Wolfinger GJ, "Immediate functional loading of Brånemark system implants in edentulous mandibles: clinical report of the results of developmental and simplified protocols", Int J Oral Maxillofac Implants, 18, pp.250~257 (2003)
- Ioannidou E, "Does loading time affect implant survival? A meta-analysis of 1,266 implants", J Periodontol, 76, pp.1252~1258 (2005)
- Fuster-Torres MA, "CAD", CAM dental systems in implant dentistry: update, 2009, pp.14, 141~145
- Strub JR, "Computer-aided design and fabrication of dental restorations: current systems and future possibilities", J Am Dent Assoc, 137, pp.1289~1296 (2006)
- Verstreken K, "Computer- assisted planning of oral implant surgery: a three- dimensional approach", Int J Oral Maxillofac Implants, 11, pp.806~810 (1996)
- Tee-Khin N, "The management of a completely edentulous patient using simultaneous maxillary and mandibular CAD", CAM-guided immediately loaded definitive implant-supported prostheses: a clinical report, 2008, pp.99, 416~420
- Balshi SF, "Surgical planning and prosthesis construction using computed tomography, CAD", CAM technology, and the Internet for immediate loading of dental implants, 2006, pp.18, 312~323
- Kupeyan HK, "Definitive CAD", CAM-guided prosthesis for immediate loading of bone-grafted maxilla: a case report, 2006, pp.8, 161~167
- van Steenberghe D, "A computed tomographic scan-derived customized surgical template and fixed prosthesis for flapless surgery and immediate loading of implants in fully edentulous maxillae: a prospective multicenter study", Clin Implant Dent Relat Res, 7, pp.111~120 (2005)
- Marchack CB, "An immediately loaded CAD", CAM-guided definitive prosthesis: a clinical report, 2005, pp.93, 8~12
- van Steenberghe D, "A custom template and definitive prosthesis allowing immediate implant loading in the maxilla: a clinical report", Int J Oral Maxillofac Implants, 17, pp.663~670 (2002)
- Takahashi T, "Fit of implant frameworks: an in vitro comparison between two fabrication techniques", J Prosthet Dent, 89, pp.256~260 (2003)
- Torsello F, "Evaluation of the marginal precision of one-piece complete arch titanium frameworks fabricated using five different methods for implant-supported restorations", Clin Oral Implants Res, 19, pp.772~779 (2008)
- Kim Y, "Occlusal considerations in implant therapy: clinical guidelines with biomechanical rationale", Clin Oral Implants Res, 16, pp.26~35 (2005)
- Yong LT, "Complications of computer- aided-design", computer-aided-machining-guided (NobelGuide) surgical implant placement: an evaluation of early clinical results, 2008, pp.10, 123~127
- Komiyama A, "Treatment outcome of immediately loaded implants installed in edentulous jaws following computer-assisted virtual treatment planning and flapless surgery", Clin Oral Implants Res, 19, pp.677~685 (2008)
- Rocci A, "Immediate loading of Brånemark System TiUnite and machined-surface implants in the posterior mandible: a randomized open-ended clinical trial", Clin Implant Dent Relat Res, 5(1), pp.57~63 (2003)
- Grunder U, "Immediate functional loading of immediate implants in edentulous arches: two-year results", Int J Periodontics Restorative Dent, 21, pp.545~551 (2001)
- Schnitman PA, "Ten-year results for Brånemark implants immediately loaded with fixed prostheses at implant placement", Int J Oral Maxillofac Implants, 12, pp.495~503 (1997)