Full Mouth Rehabilitation with Modeless Implant Restoration using a Two-step Surgical Guide System: A Case Report
1
조회
0
다운로드
1
인용
0
참고문헌
키워드
초록
As digital dentistry has become widespread and increasingly popular in clinical practice, various attempts have been made to use digital technologies for dental treatment. Implant surgical guides that use these digital technologies have been widely used in recent implant surgeries. The seating and stability of implant surgical guides are essential to accurately transfer the planned surgery into the oral cavity. This case study aimed to explore the two-step surgical guide system to increase the stability of implant surgical guides for implant surgery in a patient with full extraction. In addition, this study attempted to report a clinical case in which fixed prosthetic restoration was completed by converting mucosal-supported surgical guides into tooth- and mucosal-supported surgical guides, and maintaining the vertical dimension through intraoral scanning.
Abstract
As digital dentistry has become widespread and increasingly popular in clinical practice, various attempts have been made to use digital technologies for dental treatment. Implant surgical guides that use these digital technologies have been widely used in recent implant surgeries. The seating and stability of implant surgical guides are essential to accurately transfer the planned surgery into the oral cavity. This case study aimed to explore the two-step surgical guide system to increase the stability of implant surgical guides for implant surgery in a patient with full extraction. In addition, this study attempted to report a clinical case in which fixed prosthetic restoration was completed by converting mucosal-supported surgical guides into tooth- and mucosal-supported surgical guides, and maintaining the vertical dimension through intraoral scanning.
참고문헌 (13)
- D’Haese J, "Current state of the art of computer-guided implant surgery", Periodontol 2000, 73, pp.121~133 (2017)
- Patel N, "Integrating three-dimensional digital technologies for comprehensive implant dentistry", J Am Dent Assoc, 141, pp.20S~24S (2010)
- Pyo SW, "Methods used to assess the 3D accuracy of dental implant positions in computer-guided implant placement : A Review", J Clin Med, 8, pp.54~ (2019)
- Chen P, "Guided implant surgery : A technique whose time has come", Dent Clin North Am, 65, pp.67~80 (2021)
- D'Souza KM, "Types of implant surgical guides in dentistry : A review", J Oral Implantol, 38, pp.643~652 (2012)
- Vermeulen J, "The accuracy of implant placement by experienced surgeons : guided vs freehand approach in a simulated plastic model", Int J Oral Maxillofac Implants, 32, pp.617~624 (2017)
- Roberto P, "The impact of surgical guide fixation and implant location on accuracy of static computer-assisted implant surgery", J Prosthodont, 31, pp.155~164 (2022)
- Raico Gallardo YN, "Accuracy comparison of guided surgery for dental implants according to the tissue of support : A systematic review and meta-analysis", Clin Oral Implants Res, 28, pp.602~612 (2017)
- Pozzi A, "Guided surgery with tooth-supported templates for single missing teeth : A critical review", Eur J Oral Implantol, 9, pp.S135~S153 (2016)
- Carosi P, "Accuracy of computer-assisted flapless implant placement by means of mucosa-supported templates in complete-arch restorations : A systematic review", Materials(Basel), 15, pp.1462~ (2022)
- Ravidà A, "Clinical outcomes and cost effectiveness of computer-guided versus conventional implant-retained hybrid prostheses : A long-term retrospective analysis of treatment protocols", J Periodontol, 89, pp.1015~1024 (2018)
- Vasak C, "Computed tomographybased evaluation of template(NobelGuide)–guided implant positions : A prospective radiological study", Clin Oral Implants Res, 22, pp.1157~1163 (2011)
- Venezia P, "Digital cross-mounting : A new opportunity in prosthetic dentistry", Quintessence Int, 48, pp.701~709 (2017)
