본문 바로가기
KERD
논문KCI 등재

Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design

2

조회

0

다운로드

0

인용

0

참고문헌

키워드

주제분류치의학

초록

Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was 69.4 ± 10.2 at the time of implant placement (baseline) and 81.4 ±6.9 at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.

Abstract

Purpose: Implant surface modification and implant design are the principle targets for achieving successful primary stability. The aim of this study was to measure implant stability quotient (ISQ) values of sandblasted, large-grit, acid-etched (SLA) implants with tapered straight body design during the healing period, and to determine the various factors affecting implant stability. Materials and Methods: To measure implant stability, resonance frequency analysis (RFA) was performed in 26 patients (13 women and 13 men) with 44 SLA implants with tapered straight body design. Implant stability (ISQ values) was evaluated at baseline and healing abutment connection (12 weeks), and the correlations between RFA and insertion torque (IT), bone quality, and jawbone were determined. Results: The mean ISQ value of the implants was 69.4 ± 10.2 at the time of implant placement (baseline) and 81.4 ±6.9 at the time of healing abutment connection (P < 0.05). Significant differences were found between RFA and bone quality and between RFA and jawbone (P < 0.05). No significant differences were found between RFA and IT, insertion area, fixture diameter, and implant length (P > 0.05). Conclusion: ISQ values of SLA implants with tapered straight body design were high at baseline and healing abutment connection. It was concluded that SLA implants with tapered straight body design show improved primary and secondary stability, and that immediate or early loading may be applicable.

참고문헌 (29)

  1. Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
  2. Cochran DL, "Bone response to unloaded and loaded titanium implants with a sandblasted and acidetched surface: a histometric study in the canine mandible", J Biomed Mater Res, 40, pp.1~11 (1998)[DOI]
  3. Brunski JB, "Biomechanical factors affecting the bone-dental implant interface", Clin Mater, 10, pp.153~201 (1992)[DOI]
  4. Sennerby L, "Surgical determinants of clinical success of osseointegrated oral implants: a review of the literature", Int J Prosthodont, 11, pp.408~420 (1998)
  5. Klokkevold PR, "Osseointegration enhanced by chemical etching of the titanium surface. A torque removal study in the rabbit", Clin Oral Implants Res, 8, pp.442~447 (1997)[DOI]
  6. Piattelli A, "Histologic and histomorphometric analysis of the bone response to machined and sandblasted titanium implants: an experi- mental study in rabbits", Int J Oral Maxillofac Implants, 13, pp.805~810 (1998)
  7. Yeo IS, "Biomechanical and histomorphometric study of dental implants with different surface characteristics", J Biomed Mater Res B Appl Biomater, 87, pp.303~311 (2008)
  8. Glauser R, "Resonance frequency analysis of implants subjected to immediate or earlyfunctional occlusal loading. Successful vs. failing implants", Clin Oral Implant Res, 15, pp.428~434 (2004)[DOI]
  9. Meredith N, "Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis", Clin Oral Implants Res, 7, pp.261~267 (1996)[DOI]
  10. Sim CP, "Factors influencing resonance frequency analysis assessed by Osstell mentor during implant tissue integration: I. Instrument positioning, bone structure, implant length", Clin Oral Implants Res, 21, pp.598~604 (2010)[DOI]
  11. Ostman PO, "Resonance frequency analysis measurements of implants at placement surgery", Int J Prosthodont, 19, pp.77~83 (2006)
  12. Rowan M, "Mechanical versus biological stability of immediate and delayed implant placement using resonance frequency analysis", J Oral Maxillofac Surg, 73, pp.253~257 (2015)[DOI]
  13. Guler AU, "Resonance frequency analysis of 208 Straumann dental implants during the healing period", J Oral Implantol, 39, pp.161~167 (2013)[DOI]
  14. Boronat Lopez A, "Resonance frequency analysis of dental implant stability during the healing period", Med Oral Patol Oral Cir Bucal, 13, pp.E244~E247 (2008)
  15. Rabel A, "Clinical study on the primary stability of two dental implant systems with resonance frequency analysis", Clin Oral Investig, 11, pp.257~265 (2007)[DOI]
  16. Trisi P, "Implant micromotion is related to peak insertion torque and bone density", Clin Oral Implants Res, 20, pp.467~471 (2009)[DOI]
  17. Barone A, "The Effect of Insertion Torque on the Clinical Outcome of Single Im- plants: A Randomized Clinical Trial", Clin Implant Dent Relat Res, 18, pp.588~600 (2016)[DOI]
  18. Lai HC, "Stability of implants placed in different bone types", Zhonghua Kou Qiang Yi Xue Za Zhi, 42, pp.292~293 (2007)
  19. Turkyilmaz I, "Biomechanical aspects of primary implant stability: a human cadaver study", Clin Implant Dent Relat Res, 11, pp.113~119 (2009)[DOI]
  20. Huang HM, "Resonance frequency assessment of dental implant stability with various bone qualities: a numerical approach", Clin Oral Implants Res, 13, pp.65~74 (2002)[DOI]
  21. Friberg B, "A comparison between cutting torque and resonance frequency measurements of maxillary implants. A 20-month clinical study", Int J Oral Maxillofac Surg, 28, pp.297~303 (1999)[DOI]
  22. Bischof M, "Implant stability measurement of delayed and immediately loaded implants during heal- ing", Clin Oral Implants Res, 15, pp.529~539 (2004)[DOI]
  23. Horwitz J, "Resonance frequency analysis in immediate loading of dental implants", Refuat Hapeh Vehashinayim, 20, pp.80~88 (2003)
  24. Polizzi G, "Branemark System Wide Platform implants for single molar replacement: clinical evaluation of prospective and retrospective materials", Clin Implant Dent Relat Res, 2, pp.61~69 (2000)[DOI]
  25. Calandriello R, "Immediate occlusal loading of single lower molars using Branemark System Wide-Platform TiUnite implants: an interim report of a prospective open-ended clinical multicenter study", Clin Implant Dent Relat Res, 5, pp.74~80 (2003)[DOI]
  26. Barewal RM, "Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface", Int J Oral Maxillofac Implants, 18, pp.641~651 (2003)
  27. Balleri P, "Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study", Clin Implant Dent Relat Res, 4, pp.128~132 (2002)[DOI]
  28. Lazzara R, "Retrospectivemulticenter analysis of 3i endosseous dental implants placed over a five-year period", Clin Oral Implants Res, 7, pp.73~83 (1996)[DOI]
  29. Nedir R, "Predicting osseointegration by means of implant primary stability", Clin Oral Implants Res, 15, pp.520~528 (2004)[DOI]

관련 논문AI추천

A resonance frequency analysis of sandblasted and acid-etched implants with different diameters: a prospective clinical study during the initial healing period김연강, 김현주, 이주연, 주지영대한치주과학회 · Journal of Periodontal & Implant Science2017 · 제47권 제2호Evaluation of Dental Implant Stability with or without Photoactivated Surface Treatment강재석, 손미경, 허유리대한구강악안면임플란트학회 · 대한구강악안면임플란트학회지2021 · 제25권 제2호The effect of implant shape and bone preparation on primary stability문상현, 엄흥식, 이민구, 이재관, 장범석대한치주과학회 · Journal of Periodontal & Implant Science2010 · 제40권 제5호A comparison of the implant stability among various implant systems: clinical study김선종, 김재민, 류재준, 신상완, 한인호대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제1호Biomechanical evaluation of dental implants with different surfaces: Removal torque and resonance frequency analysis in rabbits고정우, 김성훈, 양재호, 이재봉, 한중석대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제2호Relationship between cortical bone thickness and implant stability at the time of surgery and secondary stability after osseointegration measured using resonance frequency analysisIrena Sailer, Kenko Tanaka, Kensuke Yamauchi, Nobuhiro Yoda, Ryosuke Iwama, Shinnosuke Nogami, Tetsu Takahashi대한치주과학회 · Journal of Periodontal & Implant Science2018 · 제48권 제6호

이 간행물의 다른 논문 (7건)