Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in Ø 5.0 mm implants than in Ø 4.0 mm implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.
Abstract
Purpose: The possibility of immediate or early loading has become popular in implant dentistry. A prerequisite for the immediate or early loading of an implant prosthesis is the achievement of initial stability in the implant. Moreover, in response to clinicians' interest in verifying clinical stability to determine the optimal time point for functional loading, a non-invasive method to assess implant stability has been developed on the basis of resonance frequency analysis (RFA). The primary objective of this study was to monitor the stability of sandblasted, large-grit, and acid-etched (SLA) implants with different diameters during the early phases of healing by RFA. The secondary objective was to evaluate how the initial stability of implants varied depending on different surface modifications and other contributing factors. Methods: Thirty-five implants (25 SLA implants and 10 resorbable blasting media [RBM] implants) placed in 20 subjects were included. To measure implant stability, RFA was performed at baseline and at 1, 2, 3, 4, 6, and 10 weeks after surgery. Results: The longitudinal changes in the implant stability quotient (ISQ) values were similar for the SLA implants with different diameters and for the RBM implants. During the initial healing period, the ISQ decreased after installation and reached its lowest values at 1 week and 2 weeks, respectively. The mean ISQ values in the SLA implants were significantly higher in Ø 5.0 mm implants than in Ø 4.0 mm implants. Men showed a higher ISQ than women. Mandibular sites showed a higher ISQ than maxillary sites. Conclusions: All implants used in this study are suitable for immediate or early loading under appropriate indications. A wider diameter and SLA surface treatment of implants could improve the stability, if the implant is fixed with at least 30 Ncm of insertion torque.
참고문헌 (38)
- Wennström JL, "Implant-supported single-tooth restorations : a 5-year prospective study", J Clin Periodontol, 32, pp.567~574 (2005)
- Krennmair G, "Single-tooth replacement with the Frialit-2 system : a retrospective clinical analysis of 146 implants", Int J Oral Maxillofac Implants, 17, pp.78~85 (2002)
- Romeo E, "Long-term survival and success of oral implants in the treatment of full and partial arches : a 7-year prospective study with the ITI dental implant system", Int J Oral Maxillofac Implants, 19, pp.247~259 (2004)
- Aparicio C, "Immediate", early loading of dental implants: a report from the Sociedad Española de Implantes World Congress consensus meeting in Barcelona, Spain, 2002, 2003, pp.5, 57~60
- Schnitman PA, "Immediate fixed interim prostheses supported by two-stage threaded implants : methodology and results", J Oral Implantol, 16, pp.96~105 (1990)
- Friberg B, "Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study", Int J Oral Maxillofac Surg, 28, pp.266~272 (1999)
- Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
- Rabel A, "Clinical study on the primary stability of two dental implant systems with resonance frequency analysis", Clin Oral Investig, 11, pp.257~265 (2007)
- Szmukler-Moncler S, "Considerations preliminary to the application of early and immediate loading protocols in dental implantology", Clin Oral Implants Res, 11, pp.12~25 (2000)
- Raghavendra S, "Early wound healing around endosseous implants : a review of the literature", Int J Oral Maxillofac Implants, 20, pp.425~431 (2005)
- Suzuki S, "Implant stability change and osseointegration speed of immediately loaded photofunctionalized implants", Implant Dent, 22, pp.481~490 (2013)
- Chong L, "Effect of implant design on initial stability of tapered implants", J Oral Implantol, 35, pp.130~135 (2009)
- Abuhussein H, "The effect of thread pattern upon implant osseointegration", Clin Oral Implants Res, 21, pp.129~136 (2010)
- Hudieb MI, "Magnitude and direction of mechanical stress at the osseointegrated interface of the microthread implant", J Periodontol, 82, pp.1061~1070 (2011)
- Vercaigne S, "A histological evaluation of TiO2-gritblasted and Ca-P magnetron sputter coated implants placed into the trabecular bone of the goat : part 2", Clin Oral Implants Res, 11, pp.314~324 (2000)
- Mardas N, "The effect of SLActive surface in guided bone formation in osteoporotic-like conditions", Clin Oral Implants Res, 22, pp.406~415 (2011)
- Sul YT, "Oxidized implants and their influence on the bone response", J Mater Sci Mater Med, 12, pp.1025~1031 (2001)
- Friberg B, "Evaluation of bone density using cutting resistance measurements and microradiography : an in vitro study in pig ribs", Clin Oral Implants Res, 6, pp.164~171 (1995)
- Meredith N, "Quantitative determination of the stability of the implant-tissue interface using resonance frequency analysis", Clin Oral Implants Res, 7, pp.261~267 (1996)
- Barewal RM, "Resonance frequency measurement of implant stability in vivo on implants with a sandblasted and acid-etched surface", Int J Oral Maxillofac Implants, 18, pp.641~651 (2003)
- Balleri P, "Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading : a pilot study", Clin Implant Dent Relat Res, 4, pp.128~132 (2002)
- Testori T, "Immediate nonocclusal versus early loading of dental implants in partially edentulous patients: 1-year results from a multicenter, randomized controlled clinical trial", Int J Oral Maxillofac Implants, 22, pp.815~822 (2007)
- Lindeboom JA, "Immediate loading versus immediate provisionalization of maxillary single-tooth replacements : a prospective randomized study with BioComp implants", J Oral Maxillofac Surg, 64, pp.936~942 (2006)
- Ersanli S, "Resonance frequency analysis of one-stage dental implant stability during the osseointegration period", J Periodontol, 76, pp.1066~1071 (2005)
- 오준호, "Resonance Frequency Analysis(RFA)를 이용한 임플란트 종류간의 초기 안정성 비교", Journal of Periodontal & Implant Science, 38(3), pp.529~534 (2008), 대한치주과학회
- O'Leary TJ, "The plaque control record", J Periodontol, 43, pp.38~ (1972)
- Zix J, "Stability measurements of 1-stage implants in the maxilla by means of resonance frequency analysis : a pilot study", Int J Oral Maxillofac Implants, 20, pp.747~752 (2005)
- Huwiler MA, "Resonance frequency analysis in relation to jawbone characteristics and during early healing of implant installation", Clin Oral Implants Res, 18, pp.275~280 (2007)
- Esposito M, "Interventions for replacing missing teeth: different times for loading dental implants", Cochrane Database Syst Rev, pp.CD003878~ (2013)
- Quesada-García MP, "Dental implant stability is influenced by implant diameter and localization and by the use of plasma rich in growth factors", J Oral Maxillofac Surg, 70, pp.2761~2767 (2012)
- Boronat López A, "Resonance frequency analysis of dental implant stability during the healing period", Med Oral Patol Oral Cir Bucal, 13, pp.244~247 (2008)
- Ohta K, "Influence of factors related to implant stability detected by wireless resonance frequency analysis device", J Oral Rehabil, 37, pp.131~137 (2010)
- Bischof M, "Implant stability measurement of delayed and immediately loaded implants during healing", Clin Oral Implants Res, 15, pp.529~539 (2004)
- Glauser R, "Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading. Successful vs. failing implants", Clin Oral Implants Res, 15, pp.428~434 (2004)
- Nedir R, "Predicting osseointegration by means of implant primary stability", Clin Oral Implants Res, 15, pp.520~528 (2004)
- Buser D, "Long-term evaluation of non-submerged ITI implants. Part 1: 8-year life table analysis of a prospective multi-center study with 2359 implants", Clin Oral Implants Res, 8, pp.161~172 (1997)
- Bryant SR., "The effects of age, jaw site, and bone condition on oral implant outcomes", Int J Prosthodont, 11, pp.470~490 (1998)
- Brochu JF, "The influence of early loading on bony crest height and stability : a pilot study", Int J Prosthodont, 18, pp.506~512 (2005)