The effect of implant shape and bone preparation on primary stability
2
조회
0
다운로드
2
인용
0
참고문헌
키워드
초록
Purpose: The purpose of this study was to evaluate the effects of implant shape and bone preparation on the primary stability of the implants using resonance frequency analysis. Methods: Sixty bovine rib blocks were used for soft and hard bone models. Each rib block received two types of dental implant fixtures; a straight-screw type and tapered-screw type. Final drilling was done at three different depths for each implant type; 1mm under-preparation, standard preparation, and 1 mm over-preparation. Immediately after fixture insertion, the implant stability quotient (ISQ) was measured for each implant. Results: Regardless of the bone type, the ISQ values of the straight-screw type and tapered-screw type implants were not significantly different (P > 0.05). Depth of bone preparation had no significant effect on the ISQ value of straight-screw type implants (P > 0.05). For the tapered-screw type implants, under-preparation significantly increased the ISQ value (P < 0.05), whereas overpreparation significantly decreased the ISQ value (P < 0.05). Conclusions: Within the limitations of this study, it is concluded that bone density seemed to have a prevailing effect over implant shape on primary stability. The primary stability of the tapered-screw type implants might be enhanced by delicate surgical techniques.
Abstract
Purpose: The purpose of this study was to evaluate the effects of implant shape and bone preparation on the primary stability of the implants using resonance frequency analysis. Methods: Sixty bovine rib blocks were used for soft and hard bone models. Each rib block received two types of dental implant fixtures; a straight-screw type and tapered-screw type. Final drilling was done at three different depths for each implant type; 1mm under-preparation, standard preparation, and 1 mm over-preparation. Immediately after fixture insertion, the implant stability quotient (ISQ) was measured for each implant. Results: Regardless of the bone type, the ISQ values of the straight-screw type and tapered-screw type implants were not significantly different (P > 0.05). Depth of bone preparation had no significant effect on the ISQ value of straight-screw type implants (P > 0.05). For the tapered-screw type implants, under-preparation significantly increased the ISQ value (P < 0.05), whereas overpreparation significantly decreased the ISQ value (P < 0.05). Conclusions: Within the limitations of this study, it is concluded that bone density seemed to have a prevailing effect over implant shape on primary stability. The primary stability of the tapered-screw type implants might be enhanced by delicate surgical techniques.
참고문헌 (18)
- "surgery to the connection of completed prostheses", Int J Oral Maxillofac Implants, 6, pp.142~146 (1991)
- Lioubavina-Hack N, "Significance of primary stability for osseointegration of dental implants", Clin Oral Implants Res, 17, pp.244~250 (2006)
- Martinez H, "Optimal implant stabilization in low density bone", Clin Oral Implants Res, 12, pp.423~432 (2001)
- O’Sullivan D, "Influence of implant taper on the primary and secondary stability of osseointegrated titanium implants", Clin Oral Implants Res, 15, pp.474~480 (2004)
- Glauser R, "Resonance frequency analysis of implants subjected to immediate or early functional occlusal loading.Successful vs. failing implants", Clin Oral Implants Res, 15, pp.428~434 (2004)
- Garber DA, "Two-stage versus onestage--is there really a controversy?", J Periodontol, 72, pp.417~421 (2001)
- Olsson M, "MkII--a modified self-tapping Branemark implant: 3-year results of a controlled prospective pilot study", Int J Oral Maxillofac Implants, 10, pp.15~21 (1995)
- Turkyilmaz I, "Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data", Clin Implant Dent Relat Res, 10, pp.231~237 (2008)
- Lekholm U, "Patient selection and preparation. In Tissue-integrated prostheses: osseointegration in clinical dentistry", pp.199~209 (1985), Quintessence
- Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
- Pattijn V, "Resonance frequency analysis of implants in the guinea pig model: influence of boundary conditions and orientation of the transducer", Med Eng Phys, 29, pp.182~190 (2007)
- Sennerby L, "A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone", Int J Oral Maxillofac Implants, 7, pp.62~71 (1992)
- O’Sullivan D, "Measurements comparing the initial stability of five designs of dental implants: a human cadaver study", Clin Implant Dent Relat Res, 2, pp.85~92 (2000)
- Akca K, "Biomechanical aspects of initial intraosseous stability and implant design:a quantitative micro-morphometric analysis", Clin Oral Implants Res, 17, pp.465~472 (2006)
- Andres-Garcia R, "In vitro evaluation of the influence of the cortical bone on the primary stability of two implant systems", Med Oral Patol Oral Cir Bucal, 14, pp.E93~97 (2009)
- O’Sullivan D, "A comparison of two methods of enhancing implant primary stability", Clin Implant Dent Relat Res, 6, pp.48~57 (2004)
- Akkocaoglu M, "Implant design and intraosseous stability of immediately placed implants: a human cadaver study", Clin Oral Implants Res, 16, pp.202~209 (2005)
- 오갑용, "임플랜트 고정체의 형태가 임플랜트 초기안정성에 미치는 영향", 대한치과보철학회지, 45(1), pp.98~106 (2007), 대한치과보철학회