Purpose: It has been suggested that resonance frequency analysis (RFA) can measure changes in the stability of dental implants during osseointegration. This retrospective study aimed to evaluate dental implant stability at the time of surgery (primary stability; PS) and secondary stability (SS) after ossseointegration using RFA, and to investigate the relationship between implant stability and cortical bone thickness. Methods: In total, 113 patients who attended the Tohoku University Hospital Dental Implant Center were included in this study. A total of 229 implants were placed in either the mandibular region (n=118) or the maxilla region (n=111), with bone augmentation procedures used in some cases. RFA was performed in 3 directions, and the lowest value was recorded. The preoperative thickness of cortical bone at the site of implant insertion was measured digitally using computed tomography, excluding cases of bone grafts and immediate implant placements. Results: The mean implant stability quotient (ISQ) was 69.34±9.43 for PS and 75.99±6.23 for SS. The mandibular group had significantly higher mean ISQ values than the maxillary group for both PS and SS (P<0.01). A significant difference was found in the mean ISQ values for PS between 1-stage and 2-stage surgery (P<0.5). The mean ISQ values in the non-augmentation group were higher than in the augmentation group for both PS and SS (P<0.01). A weak positive correlation was observed between cortical bone thickness and implant stability for both PS and SS in all cases (P<0.01). Conclusions: Based on the present study, the ISQ may be affected by implant position site, the use of a bone graft, and cortical bone thickness before implant therapy

Abstract

Purpose: It has been suggested that resonance frequency analysis (RFA) can measure changes in the stability of dental implants during osseointegration. This retrospective study aimed to evaluate dental implant stability at the time of surgery (primary stability; PS) and secondary stability (SS) after ossseointegration using RFA, and to investigate the relationship between implant stability and cortical bone thickness. Methods: In total, 113 patients who attended the Tohoku University Hospital Dental Implant Center were included in this study. A total of 229 implants were placed in either the mandibular region (n=118) or the maxilla region (n=111), with bone augmentation procedures used in some cases. RFA was performed in 3 directions, and the lowest value was recorded. The preoperative thickness of cortical bone at the site of implant insertion was measured digitally using computed tomography, excluding cases of bone grafts and immediate implant placements. Results: The mean implant stability quotient (ISQ) was 69.34±9.43 for PS and 75.99±6.23 for SS. The mandibular group had significantly higher mean ISQ values than the maxillary group for both PS and SS (P<0.01). A significant difference was found in the mean ISQ values for PS between 1-stage and 2-stage surgery (P<0.5). The mean ISQ values in the non-augmentation group were higher than in the augmentation group for both PS and SS (P<0.01). A weak positive correlation was observed between cortical bone thickness and implant stability for both PS and SS in all cases (P<0.01). Conclusions: Based on the present study, the ISQ may be affected by implant position site, the use of a bone graft, and cortical bone thickness before implant therapy

참고문헌 (36)

  1. Adell R, "A 15-year study of osseointegrated implants in the treatment of the edentulous jaw", Int J Oral Surg, 10, pp.387~416 (1981)
  2. Albrektsson T, "The long-term efficacy of currently used dental implants: a review and proposed criteria of success", Int J Oral Maxillofac Implants, 1, pp.11~25 (1986)
  3. Albrektsson T, "Osseointegrated titanium implants. Requirements for ensuring a long-lasting, direct bone-to-implant anchorage in man", Acta Orthop Scand, 52, pp.155~170 (1981)
  4. Meredith N, "Assessment of implant stability as a prognostic determinant", Int J Prosthodont, 11, pp.491~501 (1998)
  5. Lekholm U, "Survival of the Brånemark implant in partially edentulous jaws: a 10-year prospective multicenter study", Int J Oral Maxillofac Implants, 14, pp.639~645 (1999)
  6. Sennerby L, "A morphometric and biomechanic comparison of titanium implants inserted in rabbit cortical and cancellous bone", Int J Oral Maxillofac Implants, 7, pp.62~71 (1992)
  7. Atieh MA, "Can resonance frequency analysis predict failure risk of immediately loaded implants", Int J Prosthodont, 25, pp.326~339 (2012)
  8. Oh JS, "Clinical study of the relationship between implant stability measurements using Periotest and Osstell mentor and bone quality assessment", Oral Surg Oral Med Oral Pathol Oral Radiol, 113, pp.e35~e40 (2012)
  9. Turkyilmaz I, "Two alternative surgical techniques for enhancing primary implant stability in the posterior maxilla: a clinical study including bone density, insertion torque, and resonance frequency analysis data", Clin Implant Dent Relat Res, 10, pp.231~237 (2008)
  10. Geckili O, "Three-year radiologic follow-up of marginal bone loss around titanium dioxide grit-blasted dental implants with and without fluoride treatment", Int J Oral Maxillofac Implants, 26, pp.319~324 (2011)
  11. Marković A, "Evaluation of primary stability of self-tapping and non-self-tapping dental implants. A 12-week clinical study", Clin Implant Dent Relat Res, 15, pp.341~349 (2013)
  12. Ivanoff CJ, "Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits", Clin Oral Implants Res, 7, pp.120~127 (1996)
  13. Seong WJ, "Comparison of push-in versus pull-out tests on bone-implant interfaces of rabbit tibia dental implant healing model", Clin Implant Dent Relat Res, 15, pp.460~469 (2013)
  14. Benic GI, "Loading protocols for single-implant crowns: a systematic review and meta-analysis", Int J Oral Maxillofac Implants, 29(Suppl), pp.222~238 (2014)
  15. Schrott A, "Implant loading protocols for partially edentulous patients with extended edentulous sites--a systematic review and meta-analysis", Int J Oral Maxillofac Implants, 29(Suppl), pp.239~255 (2014)
  16. Schimmel M, "Loading protocols for implant-supported overdentures in the edentulous jaw: a systematic review and meta-analysis", Int J Oral Maxillofac Implants, 29(Suppl), pp.271~286 (2014)
  17. Friberg B, "Stability measurements of one-stage Brånemark implants during healing in mandibles. A clinical resonance frequency analysis study", Int J Oral Maxillofac Surg, 28, pp.266~272 (1999)
  18. Miyamoto I, "Influence of cortical bone thickness and implant length on implant stability at the time of surgery--clinical, prospective, biomechanical, and imaging study", Bone, 37, pp.776~780 (2005)
  19. Manzano-Moreno FJ, "Factors affecting dental implant stability measured using the ostell mentor device: a systematic review", Implant Dent, 24, pp.565~577 (2015)
  20. Norton MR, "Bone classification: an objective scale of bone density using the computerized tomography scan", Clin Oral Implants Res, 12, pp.79~84 (2001)
  21. Shahlaie M, "Bone density assessments of dental implant sites: 1. Quantitative computed tomography", Int J Oral Maxillofac Implants, 18, pp.224~231 (2003)
  22. Nedir R, "Predicting osseointegration by means of implant primary stability", Clin Oral Implants Res, 15, pp.520~528 (2004)
  23. Balleri P, "Stability measurements of osseointegrated implants using Osstell in partially edentulous jaws after 1 year of loading: a pilot study", Clin Implant Dent Relat Res, 4, pp.128~132 (2002)
  24. Ersanli S, "Resonance frequency analysis of one-stage dental implant stability during the osseointegration period", J Periodontol, 76, pp.1066~1071 (2005)
  25. Ostman PO, "Resonance frequency analysis measurements of implants at placement surgery", Int J Prosthodont, 19, pp.77~83 (2006)
  26. Bischof M, "Implant stability measurement of delayed and immediately loaded implants during healing", Clin Oral Implants Res, 15, pp.529~539 (2004)
  27. Tallarico M, "A prospective case-control clinical trial comparing 1- and 2-stage Nobel Biocare TiUnite implants: resonance frequency analysis assessed by Osstell Mentor during integration", Quintessence Int, 42, pp.635~644 (2011)
  28. Al-Khaldi N, "Stability of dental implants in grafted bone in the anterior maxilla: longitudinal study", Br J Oral Maxillofac Surg, 49, pp.319~323 (2011)
  29. Rasmusson L, "Stability evaluation of implants integrated in grafted and nongrafted maxillary bone: a clinical study from implant placement to abutment connection", Clin Implant Dent Relat Res, 14, pp.61~66 (2012)
  30. Sjöström M, "Monitoring of implant stability in grafted bone using resonance frequency analysis. A clinical study from implant placement to 6 months of loading", Int J Oral Maxillofac Surg, 34, pp.45~51 (2005)
  31. Degidi M, "Primary stability determination of implants inserted in sinus augmented sites: 1-step versus 2-step procedure", Implant Dent, 22, pp.530~533 (2013)
  32. Turkyilmaz I, "Stability and marginal bone level measurements of unsplinted implants used for mandibular overdentures: a 1-year randomized prospective clinical study comparing early and conventional loading protocols", Clin Oral Implants Res, 17, pp.501~505 (2006)
  33. Karl M, "Parameters of resonance frequency measurement values: a retrospective study of 385 ITI dental implants", Clin Oral Implants Res, 19, pp.214~218 (2008)
  34. Ivanoff CJ, "Influence of initial implant mobility on the integration of titanium implants. An experimental study in rabbits", Clin Oral Implants Res, 7, pp.120~127 (1996)
  35. Cochran DL, "Bone response to unloaded and loaded titanium implants with a sandblasted and acid-etched surface: a histometric study in the canine mandible", J Biomed Mater Res, 40, pp.1~11 (1998)
  36. Becker W, "Long-term evaluation of 282 implants in maxillary and mandibular molar positions: a prospective study", J Periodontol, 70, pp.896~901 (1999)

관련 논문AI추천

The evaluation of implant stability measured by resonance frequency analysis in different bone typesAmin Khajavi, Habibollah Ghanbari, Hamidreza Arab, Leila Khodadadifard, Naser Sargolzaie, Sarah Samizade대한구강악안면외과학회 · 대한구강악안면외과학회지2019 · 제45권 제1호Effect of bone quality and implant surgical technique on implant stability quotient (ISQ) value곽재영, 김성균, 윤홍기, 이수영, 허성주대한치과보철학회 · The Journal of Advanced of Prosthodontics2011 · 제3권 제1호A comparison of the implant stability among various implant systems: clinical study김선종, 김재민, 류재준, 신상완, 한인호대한치과보철학회 · The Journal of Advanced of Prosthodontics2009 · 제1권 제1호Evaluation of the stability of sandblasted, large-grit, acid-etched implants with tapered straight body design김용건, 이규복대한턱관절교합학회 · 구강회복응용과학지2018 · 제34권 제2호Primary implant stability in a bone model simulating clinical situations for the posterior maxilla: an in vitro study허익, 신승윤, 신승일, 안수진, 임현창, 정종혁, 한지영, 한호철, 홍지연대한치주과학회 · Journal of Periodontal & Implant Science2016 · 제46권 제4호임플란트 식립 부위의 골밀도 평가에 관한 연구김창환, 박봉찬, 박수원, 성일용, 손장호, 손한나, 이지호, 장수미, 조영철, 최병환대한구강악안면외과학회 · 대한구강악안면외과학회지2010 · 제36권 제5호

이 간행물의 다른 논문 (6건)