논문KCI 등재
Advanced Design of Birdcage RF Coil for Various AbsorptionRegions at 3T MRI System
2
조회
0
다운로드
0
인용
0
참고문헌
주제분류화학
참고문헌 (14)
- Harpen MD, "Equivalent circuit for birdcage resonators", Magn Reson Med., 29, pp.263~268 (1993)
- Harpen MD, "Cylindrical coils near self-resonance", Magn Reson Med., 30, pp.489~493 (1993)
- Wen H, "The design and test of a new volume coil for high field imaging", Magn Reson Med., 32, pp.492~498 (1994)
- Jin J, "Electromagnetic analysis and design in magnetic resonance imaging. 1st ed.", CRC, Press, 24, pp.243~252 (1999)
- Leifer MC, "Resonant modes of the birdcage coil", J Magn Reson, 124, pp.51~60 (1997)
- Jin J, "On the field inhomogeneity of a birdcage coil", Magn Reson Med., 32, pp.418~422 (1994)
- Leifer MC, "Theory of the quadrature elliptic birdcage coil", Magn Reson Med., 38, pp.726~732 (1992)
- Pascone RJ, "Generalized electrical analysis of low-pass and high-pass birdcage resonators", Magn Reson Imaging., 9, pp.395~408 (1991)
- Bowtell RW, "NMR microscopy of single neurons using spin echo and line narrowed 2DFT imaging", Magn Reson Med., 33, pp.790~794 (1995)
- Callaghan PT, "Principles of Nuclear Magnetic Resonance Microscopy" (1991), Clarendon Press, Oxford
- Pascone R, "Use of transmission line analysis for multi-tuning of birdcage resonators", Magn Reson Imaging., 11, pp.705~715 (1993)
- D.I. Hoult, "The Signalto-Noise Ratio of The Nuclear Magnetic Resonance Experiment.", J. Magn Reson, 24, pp.71~85 (1976)
- Vaughan JT, "High frequency volume coils for clinical NMR imaging and spectroscopy.", Magn Reson Med., 32, pp.206~218 (1994)
- Harpen MD, "Radiative losses of a birdcage resonator", Magn Reson Med., 29, pp.713~716 (1993)
관련 논문AI추천
RF Shimming Considering Coupling Effects for High-Field MRI이수열, 조민형, 허혜영대한의용생체공학회 · 의공학회지2008 · 제29권 제4호Fabrication of a Staircase Coil with Improved SNR and Image Uniformity by Structural Changes of a Conventional Birdcage Coil at 1.5T MRI량경승, 신용진한국자기공명학회 · Journal of the Korean Magnetic Resonance Society2003 · 제7권 제1호Time-Multiplexed RF Transmission to Improve B1 Homogeneity in High Field MRI이수열, 한병희, Hye Young Heo, Jeung Hun Seo대한의용생체공학회 · 의공학회지2008 · 제29권 제2호A Review on the RF Coil Designs and Trends for Ultra High Field Magnetic Resonance Imaging김경남, Jose Daniel Hernandez Chang대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2020 · 제24권 제3호3.0 Tesla 자기공명영상시스템에서 고 해상도 나선주사영상강승원, 김판기, 박호종, 안창범, 오승준, 이흥규, 임종우, 임헌진, 전수열, 조상흠대한자기공명의과학회 · Investigative Magnetic Resonance Imaging2006 · 제10권 제2호소 동물 1H 1.5 T 자기공명영상 장치용 유연인쇄기판 기반 새장형 수신 코일 센서김현덕, Sheikh Faisal Ahmad한국센서학회 · 센서학회지2017 · 제26권 제4호
이 간행물의 다른 논문 (6건)
The V(IV) Species, Location and Adsorbate Interactions in VH-SAPO-11 studied by ESR and ESEM백성찬, 박성건, 백건호, 이철휘pp. 1-2011B NMR study of MgB2 superconductor이용일, W.P. Halperin, 이무희, 조병기pp. 21-28PFG NMR Study of Intra-cellular Drug Uptake in Xenopus laevis Oocyte이상도, 정재준, 홍관수, 염규선, 김은희, 조지현, 이철현pp. 29-37Solution Structure of a GSK 3b Binding Motif, AXINpep최강렬, 이원태, 김영철, 정진원, 김현이, 박희영pp. 38-47Investigation of xV2O5-B2O3 and xV2O5-B2O3-yNa2O Glassesby 11B MAS NMR강재필, 김선하, 송선기, 한옥희pp. 61-66
