본문 바로가기
KERD
논문KCI 등재

Evaluation of CDMA Network Based Wireless 3 Channel ECG Monitoring System

2

조회

0

다운로드

3

인용

0

참고문헌

키워드

초록

A wireless 3 channel ECG monitoring system was developed so that it could monitor the health and movement state during subject's daily life. The developed system consists of a wireless biomedical signal acquisition device, a personal healthcare server, and a remote medical server. Three experiments were performed to evaluate the accuracy, reliability and operability, applicability during daily life of the developed device. First, ECG signals were measured using the developed device and commercial reference device during sitting and marking time and compared to verify the accuracy of R-R intervals. Second, the reliable data transmission to remote server was verified on two types of simulated emergency event using patient simulator. Third, during five types of motion in daily life, the accuracy of data transmission to remote server using CDMA network was verified on two types of event occurring. By acquiring and comparing subject's biomedical signal and motion signal, the accuracy, reliability and operability, applicability during daily life of the developed device were verified. In addition, PDA-phone based wireless system enabled subject to be monitored without any constraints. Therefore, the developed system is expected to be applicable for monitoring the aged and chronic diseased people and giving first-aid in emergency.

Abstract

A wireless 3 channel ECG monitoring system was developed so that it could monitor the health and movement state during subject's daily life. The developed system consists of a wireless biomedical signal acquisition device, a personal healthcare server, and a remote medical server. Three experiments were performed to evaluate the accuracy, reliability and operability, applicability during daily life of the developed device. First, ECG signals were measured using the developed device and commercial reference device during sitting and marking time and compared to verify the accuracy of R-R intervals. Second, the reliable data transmission to remote server was verified on two types of simulated emergency event using patient simulator. Third, during five types of motion in daily life, the accuracy of data transmission to remote server using CDMA network was verified on two types of event occurring. By acquiring and comparing subject's biomedical signal and motion signal, the accuracy, reliability and operability, applicability during daily life of the developed device were verified. In addition, PDA-phone based wireless system enabled subject to be monitored without any constraints. Therefore, the developed system is expected to be applicable for monitoring the aged and chronic diseased people and giving first-aid in emergency.

참고문헌 (16)

  1. K.Y. Kong, "Web-Based Monitoring of Real-Time ECG Data", Proceedings of the 23rd Annual International Conference of the IEEE, pp.189~192 (2000)
  2. 홍주현, "u-Healthcare를 위한 PDA 기반의 무선 심전도 모니터링 시스템", 대한의료정보학회지, 12(2), pp.153~160 (2006), 대한의료정보학회
  3. R. Fensli, "A wireless ECG system for continuous event recording and communication to a clinical alarm station", Proceedings of the 26th Annual International Conference of the IEEE EMBS, San Francisco, USA, pp.2208~2211 (2004)
  4. A.I. Hernandez, "Real-Time ECG Transmission Via Internet for Nonclinical Applications", IEEE Transactions on Biomedical Engineering, 5, pp.253~257 (2001)
  5. J. Andreasson, "Remote System for Patient Monitoring Using Bluetooth", pp.304~307 (2002), Proceedings of IEEE
  6. T. Martin, "Issues in Wearable Computing for medical Monitoring Applications:A Case Study of a Wearable ECG Monitoring Device", Proceedings of the International Symposium on Wearable Computers ISWC, pp.43~50 (2000)
  7. E. Jovanov, "Wireless Technology and System Integration in Body Area Networks for m-Health Applications", Proceedings of the 2005 IEEE Engineering in Medicine and Biology 27th Annual Conference, pp.7158~7160 (2005)
  8. C.A. Otto, "A WBAN-based System for Health Monitoring at Home", Proceedings of the 3rd IEEE-EMBS International Summer School and Symposium on Medical Devices and Biosensors, pp.20~23 (2006)
  9. F. Foerster, "Detection of Posture and Motion by accelerometry: A Validation study in ambulatory monitoring", Comput Hun Beh, 15(5), pp.571~583 (1999)
  10. B.C. Spillman, "The effect of longevity on spending for acute and long-term care", pp.1409~1415 (2000), N Eng J Med
  11. S. Tuljapurkar, "A universal pattern of mortality decline in the countries", Nature, 15(405), pp.789~792 (2000)
  12. L.W. Keijsers, "Automatic Assessment of Levodopa-Induced Dyskinesias in Daily Life by Neural Networks", Movement Disorders, 18(1), pp.70~80 (2003)
  13. B. Najafi, "Ambulatory system for human motion analysis using a kinematic sensor: monitoring of daily physical activity in the elderly", IEEE transactions on biomedical engineering, 50(6), pp.711~723 (2003)
  14. Y.H. Lin, "A Wireless PDA-based physiological monitoring system for patient transport", IEEE Transactions on Information Technology In Biomedicine, 8(4), pp.439~447 (2004)
  15. W. Chen, "A Mobile Phone-based Wearable Vital Signs Monitoring System", Proceedings of the 2005 the fifth International Conference on Computer and Information Technology, pp.950~955 (2005)
  16. K.J. Heilman, "Accuracy of the LifeShirtⓇ(Vivometrics) in the detection of cardiac rhythms", Biological Psychology, 75(3), pp.300~305 (2007)

이 간행물의 다른 논문 (10건)