Time-Varying Hemodynamic Characteristics Simulation using Computerized Mock Circulatory Loop System with Servo Flow Regulator
2
조회
0
다운로드
0
인용
0
참고문헌
키워드
초록
A mock circulatory loop system has been developed to construct a simulator for trainees in cardiopulmonary bypass systems or to simulate a test environment for cardiac-assist devices. This paper proposes a computerized mock circulatory loop system whose node is modularized by using a servo control flow regulator to simulate dynamic change of the hemodynamic status. To observe the effect of time-varying resistance, one with hemodynamic properties, the proposed system replicates the planned cross-sectional areas of the outlet of a ventricular assist device in terms of voltage input of a servo valve. The experiment is performed (1) for steady-input commands of selected area sizes and (2) for dynamic commands such as monotonous increase and decrease, and oscillatory functions of the voltage input, and a computer program based on LabVIEW (National Instruments, Austin, USA) processes every measured data and control command to the servo valve. The results show that the pressure and flow at the target points with respect to time-varying resistance match intuitive estimation: the pressure at the outlet and the pressure drop between both sides of the valve increased and the flow at the outlet decreased for increased resistance.
Abstract
A mock circulatory loop system has been developed to construct a simulator for trainees in cardiopulmonary bypass systems or to simulate a test environment for cardiac-assist devices. This paper proposes a computerized mock circulatory loop system whose node is modularized by using a servo control flow regulator to simulate dynamic change of the hemodynamic status. To observe the effect of time-varying resistance, one with hemodynamic properties, the proposed system replicates the planned cross-sectional areas of the outlet of a ventricular assist device in terms of voltage input of a servo valve. The experiment is performed (1) for steady-input commands of selected area sizes and (2) for dynamic commands such as monotonous increase and decrease, and oscillatory functions of the voltage input, and a computer program based on LabVIEW (National Instruments, Austin, USA) processes every measured data and control command to the servo valve. The results show that the pressure and flow at the target points with respect to time-varying resistance match intuitive estimation: the pressure at the outlet and the pressure drop between both sides of the valve increased and the flow at the outlet decreased for increased resistance.
참고문헌 (14)
- Wieting, D. W., "Analysis of a variable volume intra-aortic balloon pump in a mock circulatory system", J. Biomech, 4, pp.37~44 (1971)
- Donovan, F., "Design of a hydraulic analog of the circulatory system for evaluating artificial hearts", Artif. Cell. Blood Sub, 3, pp.439~449 (1975)
- Guyton, A. C., "Textbook of medical physiology", pp.175~182 (2001), Saunders
- Ferrari, G., "A hybrid mock circulatory system: testing a prototype under physiologic and pathological conditions", ASAIO j, 48, pp.487~494 (2002)
- Timms, D., "A complete mock circulation loop for the evaluation of left, right, and biventricular assist devices", Artif. organs, 29, pp.564~572 (2005)
- Timms, D. L., "A compact mock circulation loop for the in vitro testing of cardiovascular devices", Artif. Organs, 35, pp.384~391 (2010)
- Legendre, D., "Mock circulatory system for the evaluation of left ventricular assist devices, endoluminal prostheses, and vascular diseases", Artif. Organs, 32, pp.461~467 (2008)
- Wu, Y., "Modeling, estimation, and control of human circulatory system with a left ventricular assist device", IEEE Trans. Contr. Syst. Tech, 15, pp.754~767 (2007)
- Conlon, M. J., "Development of a mathematical model of the human circulatory system", Ann. Biomed. Eng, 34, pp.1400~1413 (2006)
- Geertsema, A. A., "Development of a numerical simulation model of the cardiovascular system", Artif. organs, 21, pp.1297~1301 (1997)
- Baloa, L., "Elastance-based control of a mock circulatory system", Ann. Biomed Eng, 29, pp.244~251 (2001)
- Liu, Y., "Design and initial testing of a mock human circulatory loop for left ventricular assist device performance testing", Artif. organs, 29, pp.341~345 (2005)
- Hwang, C., "Development of wearable electropneumatic biventricular assist device", ASAIO J., 51, pp.38A~ (2005)
- Merritt, H. E., "Hydraulic control systems" (1967), Wiley
